Laserfiche WebLink
FATE AND TRANSPORT OUTPUT FILE, AREA II <br /> 94.0 7 40E-11 <br /> 95 0 7 40E-11 <br /> 96 0 7 40E-11 <br /> • 97 0 7 40E-11 <br /> 98 0 7.40E-11 <br /> 99 0 7 40E-11 <br /> 100 0 7 40E-11 <br /> End of DISSOLVED SOURCE GROUNDWATER MODEL OUTPUT <br /> start of model output for- <br /> volatilization from groundwater to indoor air <br /> Groundwater source concentration for volatilization model will <br /> be calculated by groundwater model <br /> -------------------------------------------- <br /> VAPOR TRANSPORT FROM GROUNDWATER TO INDOOR AIR <br /> ---------------------------------------------- <br /> Effective Diffusion Coefficient for Vadose zone <br /> ---------------------------------------------- <br /> Total thickness of subunit [cm] . . . . 1 90E+02 <br /> Air-filled porosity [-] . . . . 0.18 <br /> water-filled porosity [-] . . 0 12 <br /> Total porosity [-] . 0 30 <br /> Effective diff coeff for subunit. . . [cm2/s] 2 60E-03 <br /> Effective Diffusion coefficient for Capillary Fringe <br /> ---------------------------------------- <br /> Total thickness of subunit [cm] . . 10 <br /> Air-filled porosity [-] . 1 OOE-02 <br /> M water-filled porosity [-] 0 29 <br /> Total porosity [-] . 0 30 <br /> Effective diff. coeff for subunit. . . [cmA2/s] 7 93E-05 <br /> Effective Diffusion coefficient for Cracks in the Building Foundation <br /> --------------------------------------. .-. . . <br /> Total thickness of subunit [cm] . 15 <br /> Air-filled porosity [-] . . . 0.25 <br /> water-filled porosity [-] . . 0 0 <br /> Total porosity [-] . . . . 0 25 <br /> Effective diff. coeff. •for subunit [cm 1.12E-02 <br /> overall Effective Diffusion coefficient (for all layers) <br /> ------------------------------------------------ <br /> Overall diffusion path length [cm] 2 15E+02 <br /> (Equals the sum of the vadose zone, lens, capillary fringe <br /> and the foundation thickness) <br /> overall effective diffusion coefficient [cmA2/s] 1 40E-04 <br /> Vapor Concentration and Flux at source <br /> ------------------------------------------------ <br /> Initial vapor cont at source [g/cmA3] 0 0 <br /> Initial vapor cont at source [mg/mA3] . . . . . . . . 0 0 <br /> Initial vapor flux rate [g/cmA2/s] . . . . . . 0 0 <br /> soil gas flow rate is zero (advection not considered in this model) . <br /> CONCENTRATION IN BUILDING (annual average) <br /> . MTBE <br /> The maximum groundwater concentration (mg/1) 0.00E+00 <br /> Occurred at year 0 0 <br /> Flux into Concentration <br /> Page 3 <br />