Laserfiche WebLink
Time In: 1.00 pm <br /> Time Out: 1:50 om <br /> �...Q .. C San Joaquin County <br /> .X Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • �..• P Telephone: (209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd <br /> Food Program Service Request Inspection Report <br /> Name of Facility: EMPRESSO COFFEE HOUSE Date: 10/01/2018 <br /> Address: 222 N ELDORADO ST, STOCKTON 95202 <br /> Requestor: ROSANN CASCIARO-BURKE, TROY BURKE INC DBA EMPRESSO COFF Telephone: (209)598-8818 <br /> Program Element: 1602-FOOD CONSULTATION Request#: SR0079659 <br /> Inspection Type: 061 -CONSULTATION <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of <br /> the food facility. <br /> #6 Handwashing Facilities Supplied and Accessible <br /> OBSERVATIONS:Provide soap and paper towel dispensers for hand sinks. <br /> CALCODE DESCRIPTION:Handwashing soap and towels or drying device shall be provided in dispensers dispensers shall be <br /> maintained in good repair. (113953.2) Adequate facilities shall be provided for hand washing,food preparation and the washing of <br /> utensils and equipment. (113953, 113953.1, 114067(0) <br /> #7 Hot and Cold Holding Temperatures <br /> OBSERVATIONS:The 2 door prep cooler shall be 41 F or lower. <br /> CALCODE DESCRIPTION:Potentially hazardous foods shall be held at or below 41/45°F or at or above 135°F. (113996, 113998, <br /> 114037, 114343(a)) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:Lack of prep sink. Provide prep sink with a drain board.Waste shall indirectly go into a floor sink. <br /> Provide air gap. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS: Install ice machine.Waste shall indirectly go into a floor sink. Provide air gap. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> FA0015223 SR0079659 SC061 10/01/2018 <br /> EHD 16-23 Rev.06/30/15 Page 1 of 3 Food Program Service Request Inspection Report <br />