Laserfiche WebLink
1 <br /> ANALYSIS REPORT <br /> A(tenticn Drew Van Allen Date Sampled: 09/23r02 <br /> ATC Associates, Inc. Dale Received: 091210, - <br /> 1117 Lone Palm Avenue Date Analyzed: 09/26/02, 10/1T02 <br /> Modesto, CA 95351 <br /> Project Advanced International Inc.i .54.62580.0001 <br /> .MethodEPA 60108 & 7470A(w) <br /> Client Sample I.D. MW-1 MW-2 Mw- <br /> LAB. NO. W0902639 W0902640 W0902641 <br /> ANALYTE R/L Results R/L Results I R/L I Results <br /> Antimony 0.0050 ND 0.0050 NO 0.0050 ND <br /> Arsenic 0.0050 0.0094 0.0050 0.010 0.0050 0.067 <br /> Beryllium 0.0030 NO 0.0030 NO 0.0030 NO <br /> Cadmium 0.0030 ND 0.0030NO 0.0030 NO <br /> Chromium 0.0030 ND 0.0030 0.010 0.0030 NO <br /> Copper 0.0030 ND 0.0030 0.020 0.0030 NO <br /> Nickel 0.0030 ND 0.00301 0.020 0.0030 ND <br /> Lead 0.0050 ND 0.00501 ND 0.00501 ND <br /> • Mercury 0.20 NO 0.20 ND 0.20 NO <br /> Silver 0.0030 NO 0.0030 NO 0.0030 NO <br /> Selenium 0.0050 0.0090 0.0050 0.058 0.0050 NO <br /> Thallium 0.0030 ND 0.0030 ND 0.0030 NO <br /> Zinc 0.010 NO 0.010 0.060 0.010 0.010 <br /> NO = Not detected. Compound(s) may be present at concentrations below the reporting limit. <br /> R/L= Reporting Limit <br /> Water samples reported in mg/L <br /> Mercury reported in pg/L <br /> c 10/18/02 <br /> • borat Representative Date Reported <br /> EXCELCHEM ENVIRONMENTAL LABS IS CERTIFIED By THE STATE OF CALIFORNIA <br /> DEPARTMENT OF HEALTH SERVICES AS A HAZARDOUS WASTE TESTING LABORATORY <br /> (Cenoution No.2119) <br /> 1 <br />