Laserfiche WebLink
TABLE 2 <br /> Laboratory Analytical Results - Groundwater <br /> Proposed Olin Interconnect Technologies Facility <br /> (Page 1 of 1) <br /> Results in ug/L (ppb) <br /> Semi- <br /> Sample Total Oil and Pesticides Volatile <br /> Well ID Date Cyanide Grease and PCBs' VOCs' Organics' Metals' <br /> MW-1 06/22/95 ND NO NO NO ND As-10 <br /> Cu-26 <br /> Zn-10 <br /> MW-2 06/22/95 NO NO NO Chloroform NO As-17 <br /> 2.2 Cr-23 <br /> Cu-36 <br /> Ni-19 <br /> Zn-40 <br /> MW-3 06/22/95 ND NO NO ND NO As-10 <br /> Cr-19 <br /> Cu-39 <br /> Ni-16 <br /> Zn-37 <br /> SB-1 06/21/95 ND NO ND ND NO As-43 <br /> Be-25 <br /> Cr-370 <br /> Cu-720 <br /> Pb-960 <br /> Hg-5.5 <br /> Ni-1700 <br /> Zn-2700 <br /> B-1-W 10/21/94 NO NA - NA NA NA Cr-8 <br /> Cu-7 <br /> Zn-250 <br /> B-2-W 10/21/94 NO NO ND NO Bis-(2- Cu-10 <br /> ethylhaxyl) Zn-250 <br /> phthalate <br /> 21 <br /> 8-3-W 10/21/94 NO NA NA NA NA Cr-7 <br /> Cu-8 <br /> Zn-300 <br /> B-4-W 10/21/94 NO NO NO NO Bis-(2- Cu-7 <br /> ethylhaxyl) Zn-300 <br /> phthalata <br /> 24 <br /> NOTES: <br /> ug/L(ppb) Micrograms per liter (parts per billion) <br /> NO = Not detected at or above Method Detection Limits <br /> NA = Not analyzed <br /> As — Arsenic [maximum contaminant level(MCL) 50 ppb) <br /> Be = Beryllium(MCL 4 ppb) <br /> Cr = Chromium (MCL 50 ppb) <br /> Cu - Copper (MCL 1,000 ppbl <br /> Hg = Mercury (MCL 2 ppb) <br /> Ni = Nickel (MCL 100 ppb) <br /> Pb — lead (MCL 50 ppb) <br /> Zn = Zinc (MCL 5,000) <br /> = Only detected constituents were listed, all others are below method detection limits . <br /> Sea Only <br /> reports for a complete list of constituents and analysis methods <br /> N:\95136\H2O.LAB <br />