ARCHIVED REPORTS XR0000631
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
121
>
3500 - Local Oversight Program
>
PR0544166
>
ARCHIVED REPORTS XR0000631
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2019 7:16:22 PM
Creation date
2/22/2019 2:09:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000631
RECORD_ID
PR0544166
PE
3528
FACILITY_ID
FA0005252
FACILITY_NAME
GREYHOUND LINES INC
STREET_NUMBER
121
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13730011
CURRENT_STATUS
02
SITE_LOCATION
121 S CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n+ r, <br /> DECEMBER 1996 <br /> QUARTERLY STATUS REPORT (CONTINUED) <br /> In August 1994, Greyhound returned to a quarterly sampling program in response to a <br /> request from PHS-EHD (letter dated August 12, 1994) The PHS-EHD was concerned <br /> about rising water levels beneath the site and the detection of TPH-D to one of the <br /> groundwater samples collected in June 1994 <br /> The second Supplemental Site Assessment Report was submitted by Greyhound to PHS- <br /> EHD in November 1994 Greyhound received comments to the Supplemental Site <br /> Assessment Report in a letter dated February 3, 1995 In response, one additional <br /> groundwater monitoring well was proposed to define the western limns of the soil and <br /> groundwater contwmnation After PHS-EHD approval, the proposed groundwater <br /> monitoring well (MW-4) was installed on August 26, 1996 under the supervision of Mr <br /> Michael Infurna (PHS-EHD) Ten subsurface soil samples were collected from the boring <br /> advanced to install the well The groundwater and soil sample results were submitted to <br /> PHS-EHD in a Request for Closure Report, dated November 1996 PHS-EHD is <br /> currently reviewing the report <br /> • Water Level measurements from most recent sampling event <br /> Table 1 provides water level measurements and other physical data obtained during the <br /> December 11, 1996 site visit Free-product and hydrocarbon sheens were not observed in <br /> any of monitoring wells <br /> Figure 2 is a site plan that includes water level elevations based on the December 11, 1996 <br /> water level measurements The water elevations indicate that groundwater was flowing <br /> south under an estimated gradient of 0 001 feet per foot The groundwater elevations <br /> were not contoured because the elevations measured in the four wells differ by fess than <br /> 0 15 feet <br /> • Water Level measurements from previous monitoring events <br /> Table 1 presents the water level measurements and other physical data obtained during <br /> previous monitoring events Free-product and hydrocarbon sheens were not observed in <br /> any of the monitoring wells during these events <br /> • Analytical results from most recent sampling event <br /> Table 2 summarizes the analytical results from the December 1996 quarterly sampling <br /> event BTEX was not detected in the samples TPH-D was detected in MW-2 at a <br /> concentration of 3,700 µg/L and in MW-3 at a concentration of 9,300 gg/L The <br /> laboratory report and chain-of-custody record are provided in Appendix A <br /> • Analytical results from previous sampling events <br /> Table 3 presents a summary of the analytical results from all previous groundwater <br /> sampling events <br /> pARESsyRo11VOL1 WP1728878108969108969L03WW6 <br />