Laserfiche WebLink
Lancaster <br /> . Laboratories Analysis Report <br /> 2425 New Holland Pike PO Box 12425 Lancaster PA 17605.2425•717-656-2300 Fax 717-656-2681•www IaMaSterlabs COM <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No WW 4465286 <br /> MW-15D-W-050211 Grab Water <br /> Facility#=90557 Job#=386843 GRD <br /> 139 S Center St-Stockton T0607700391 MW-15D <br /> Collected 02/11/2005 15 40 by AS Account Number 10906 <br /> Submitted 02/15/2005 09 25 ChevronTexaco <br /> Reported 02/25/2005 at 10 33 6001 Bollinger Canyon Rd L4310 <br /> Discard 03/28/2005 San Ramon CA 94583 <br /> CE15D <br /> As Received <br /> CAT As Received Method Dilution <br /> No Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRO - Waters n a 12,000 250 ug/1 5 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time <br /> 06609 TPH-DRO CALUFT(Waters) n a 2,800 250 ug/l 10 <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N D 200 ug/l 1 <br /> 02500 TPH Fuels by GC (Waters) <br /> 02501 Total TPH n a 390 40 ug/l 1 <br /> 02508 TPH Motor Oil C16-C36 n a 390 40 ug/1 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C8 (n-octane)_thzough_C40_(n-tetracontane)_normal_hydrocarbons <br /> Due Co the nature of the sample matrix, the chlorobenzene surrogate standard <br /> recovery is above the range of specifications <br /> 01594 BTEX+5 Oxygenates+EDC+EDB+ETON <br /> 01587 Ethanol 64-17-5 N D 100 ug/l 2 <br /> 02010 Methyl Tertiary Butyl Ether 1634-04-4 N D 1 ug/l 2 <br /> 02013 di-Isopropyl ether 108-20-3 N D 1 ug/l 2 <br /> 02013 Ethyl t-butyl ether 637-92-3 N D 1 ug/l 2 <br /> 02014 t-Amyl methyl ether 994-05-8 N D 1 ug/l 2 <br /> 02015 t-Butyl alcohol 75-65-0 23 10 ug/l 2 <br /> 05401 Benzene 71-43-2 520 5 ug/l 10 <br /> 05402 1,2-Dichloroethane 107-06-2 N D 1 ug/l 2 <br /> 05407 Toluene 108-88-3 380 5 ug/l 10 <br /> 05412 1,2-Dibromoethane 106-93-4 N D 1 ug/l 2 <br /> 05415 Ethylbenzene 100-41-4 350 1 ug/1 2 <br /> 06310 Xylene (Total) 1330-20-7 1,100 1 ug/l 2 <br /> The reporting limits for the GC/MS volatile compounds were raised <br /> because sample dilution was necessary to bring target compounds into the <br /> calibration range of the system <br /> State of Calafornia Lab Certification No 2116 <br />