Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report � <br /> 2425 New Holland Pike PO Box 12425 Lancaster R4 17605.2425•717 6562300 Fax 717-65&2681 www IancBSterlab5 com <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No WW 4405336 <br /> MFT-I5D-W-041110 Grab Water <br /> Facs-lxty#-90557 Job#=386843 ---GRID- <br /> 139 <br /> GRD139 S Center St-Stockton 70607700391 MW-15D <br /> Collected 11/10/2004 15 25 by HK Account Number 10906 <br /> Submitted 11/13/2004 09 10 ChevronTexaco <br /> Reported 11/26/2004 at 14 04 6001 Ballinger Canyon Rd L4310 <br /> Discard 12/27/2004 San Ramon CA 94583 <br /> 1391D <br /> As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRO - Waters n a 12,000 250 ug/l 5 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time <br /> 06609 TPH-DRO CALUFT(Waters) n a 2,400 130 ug/l 5 <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Infection) 67-56-1 N D 200 ug/I 1 <br /> 02500 TPH Fuels by GC (Waters) <br /> 02501 Total TPH n a 140 40 ug/1 1 <br /> 02508 TPH Motor Oil C16-C36 n a 140 40 ug/1 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C8 (n-octane) through C40 (n-tetracontane) normal hydrocarbons <br /> Due-to-the-natur"futh"ample-matrix the-chlorobenzen"urrogate-standard <br /> recovery is above the range of specifications <br /> 01594 BTEX+5 Oxygenates+EDCYEDB+ETON <br /> 01587 Ethanol 64-17-5 N D 100 ug/l 2 <br /> 02010 Methyl Tertiary Butyl Ether 1634-04-4 N D 1 ug/1 2 <br /> 02011 di-Isopropyl ether 108-20-3 N D 1 ug/1 2 <br /> 02013 Ethyl t-butyl ether 637-92-3 N D 1 ug/I 2 <br /> 02014 t-Amyl methyl ether 994-05-8 N D 1 ug/1 2 <br /> 02015 t-Butyl alcohol 75-65-0 30 30 ug/1 2 <br /> 05401 Benzene 71-43-2 520 5 ug/1 10 <br /> 05402 1,2-Dichloroethane 107-06-2 N D i ug/1 2 <br /> 05407 Toluene 108-88-3 490 5 ug/1 10 <br /> 05412 1,2-Dibromoethane 106-93-4 N D 1 ug/l 2 <br /> 05415 Ethylbenzene 100-41-4 170 1 ug/1 2 <br /> 06310 Xylene (Total) 1330-20-7 1,400 5 u9/1 10 <br /> The reporting limits for the GC/MS volatile compounds were raised <br /> because sample dilution was necessary to bring target compounds into the <br /> Calibration range of the system <br /> State of California Lab Certification No 2116 <br />