Laserfiche WebLink
Lancaster <br /> • Laboratories Analysis Report <br /> 2425 New Holland Pike.PO Box 12425,Lancaster,PA 17605-2425•717-656-2300 Fax:717-656-2681•W WW.Iancasteriabs.com <br /> Page 2 of 3 <br /> Quality Control Summary <br /> Client Name: Chevron'Texaco Group Number: 891737 <br /> Reported: 04/22/04 at 05:04 PM <br /> Sample Matrix Quality Control <br /> MS MSD MS/MSD RPD BKG DVP DVP Dup RPD <br /> Anal eis Name RSC REC Limits RPD XAx Conc Conc RPD Max <br /> Xylene (Total) 110 115 82-130 4 30 <br /> Surrogate Quality Control <br /> Analysis Name: TPH Fuels by GC (Waters) <br /> Batch number: 041030014A <br /> Chlorobenzene Orthoterphenyl <br /> 4252531 134 102 <br /> 4252532 199* 91 <br /> Blank 88 95 <br /> LCS 95 115 <br /> LCSD 101 111 <br /> Limits: 13-154 45-138 <br /> Analysis Name: TPH - DRO CA LUFT {Waters) <br /> . Batch number: 041040002A <br /> Orthoterphenyl <br /> 4252531 83 <br /> 4252532 79 <br /> Blank 78 <br /> LCS 87 <br /> LCSD 92 <br /> Limits: 57-128 <br /> Analysis Name: TPH-GRO - Waters <br /> Batch number: 04106A08B <br /> Trifluorotoluene-F <br /> 4252531 113 <br /> 4252532 110 <br /> Blank 103 <br /> LCS 106 <br /> LCSD 104 <br /> MS 105 <br /> Limits: 57-146 <br /> Analysis Name: BTEX+5 Oxygenates+EDC+EDB <br /> Batch number: P041102AA <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 4252531 101 98 96 95 <br /> 4252532 102 101 97 97 <br /> Blank 100 96 96 93 <br /> LCS 101 97 97 96 <br /> MS 100 97 96 94 <br /> MSD 101 94 96 95 <br /> *-Outside of specification <br /> (1) The result for one or both determinations was less than five times the LOQ. <br /> (2) The background result was more than four times the spike added. <br />