Laserfiche WebLink
Lancaster <br /> Analysis nalys�s Report <br /> ,,,,,* <br /> 5 New Holland Pike,PO Brno 12425,Lancaster,PA 176052425•717-556-2300 Fax:717-656-2681-www.lancasteriabs.com <br /> Page l of 2 <br /> Lancaster Laboratories Sample No. WW 4204046 <br /> MW-7-W-040122 Grab Water <br /> Facility# 90557 J'ob# 386843 GRD <br /> 139 S Center St-Stockton ' 0607700391 MW-7 <br /> Collected:01/22/2004 12 :40 by JH Account Number: 10906 <br /> Submitted: 01/24/2004 11 :20 ChevroaTexaco <br /> Reported: 01/30/2004 at 12 :39 6001 Bollinger Canyon Rd L4310 <br /> Discard: 03/01/2004 San Ramon CA 94583 <br /> CSS07 <br /> As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name cAs Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRO - Waters n.a. 1,700. 50. ug/l 1 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time. <br /> A site-specific MSD sample was not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 05553 TPH - DRO CA LUFT (waters) n.a. 770. 50. ug/l 1 <br /> According to the California LUST Protocol, the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our #2 fuel oil reference standard (between C10 and C28 normal <br /> hydrocarbons) , <br /> Site-specific MS/MSD samples were not submitted for the project- A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N.D. 1,000. ug/l 1 <br /> The sample vial used for this analysis was submitted with headspace. <br /> 02500 TPH Fuels by GC (Waters) <br /> 02501 Total TPH n.a. 340. 40, ug/I 1 <br /> 02508 TPH Motor Oil C16-C36 n.a. 340. 40. ug/l 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C8 (n-octane) through C40 (n-tetracontane) normal hydrocarbons. <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 01594 BTEX+5 Oxygenates+EDC+EDB+ETON <br /> 01587 Ethanol 64-17-5 N.D. 500. ug/l 1 <br /> 02010 Methyl Tertiary Butyl Ether 1634-04-4 N.D. 2. ug/1 1 <br /> 02011 di-Isopropyl ether 108-20-3 N.D. 2. ug/l 1 <br /> 02013 Ethyl t-butyl ether 637-92-3 N.D. 2. ug/l 1 <br /> 02014 t-Amyl methyl ether 994-05-8 N.D. 2. ug/1 1 <br /> 02015 t-Butyl alcohol 75-65-0 N.D. 100. ug/1 1 <br /> 05401 Benzene 71-43-2 17. 0.5 ug/l 1 <br /> 05402 1,2-Dichloroethane 107-06-2 N.D. 2. ug/l 1 <br /> 05407 Toluene 108-88-3 2. 0.5 ug/l 1 <br /> 05412 1,2-Dibromoethane 106-93-4 N.D. 2. ug/l 1 <br /> 5415 Ethylbenzene 100.41-4 24. 0.5 ug/l 1 <br /> 06310 Xylene (Total) 1330-20-7 4. 0.5 ug/l 1 <br /> #=Laboratory MethodDetection Limit exceeded target detection limit <br /> N.D.=Not detected at or above the Reporting Limit <br />