Laserfiche WebLink
No target analytes were detected in any method blank or field QC samples with the following exceptions: <br /> • Equipment Rinse and Field Blank, collected on July 18, 2012, were associated with the <br /> analysis of eight samples and had detectable concentrations of sulfate (0.3 mg/L) and TOC (0.2 <br /> mg/L). Additionally, Field Blank had 0.6 mg/L of TDS detected. One sample had TOC detected <br /> at a concentration that was greater than the reporting limit, but less than five times the blank <br /> concentration, and was qualified as estimated (J). Five samples had TOC detected below the <br /> reporting limit and were qualified as non-detects (U) at the reporting limit. Sulfate and TDS were <br /> detected at concentrations that were greater than five times the blank sample concentrations, so <br /> the results were not qualified. <br /> • Equipment Rinse and Field Blank, collected on July 19, 2012, were associated with the <br /> analysis of three samples and had TOC detected at 0.7 and 0.8 mg/L, respectively, and TDS <br /> detected at 6.0 mg/L in both. TDS was detected in the associated samples at concentrations that <br /> were greater than five times the blank concentration and were not qualified. All three samples <br /> had TOC detected below the reporting limit and were qualified as non-detects (U) at the reporting <br /> limit. <br /> • Equipment Rinse and Field Blank, collected on July 23, 2012, were associated with the <br /> analysis of one sample and had TDS detected at 5.0 and 7.0 mg/L, respectively and TOC <br /> detected at 0.5 and 0.4 mg/L, respectively. Additionally, Equipment Rinse had sulfate detected <br /> at 0.3 mg/L. TDS and sulfate were detected in the associated sample at concentrations that were <br /> greater than five times the blank concentration and were not qualified. TOC was detected at a <br /> concentration that was greater than the reporting limit, but less than five times the blank result, <br /> and was qualified as estimated (J). <br /> • Equipment Rinse and Field Blank, collected on July 24, 2012, were associated with the <br /> analysis of three samples and had TDS detected at 5.0 and 6.0 mg/L, respectively; TOC detected <br /> at 0.5 and 0.4 mg/L, respectively; and sulfate detected at 0.3 mg/L in both. TDS and sulfate were <br /> detected in the associated samples at concentrations that were greater than five times the blank <br /> concentration and were not qualified. Two samples had TOC detected above the reporting limit, <br /> but less than five times the blank result, and were qualified as estimated (J). The third sample <br /> had TOC detected at a concentration that was greater than five times the blank result, and <br /> therefore was not qualified. <br /> • Equipment Rinse and Field Blank, collected on July 25, 2012, were associated with the <br /> analysis of two samples and had TDS detected at 5.0 and 7.0 mg/L, respectively, and TOC <br /> detected at 0.2 and 0.09 mg/L, respectively. TDS was detected in the associated samples at <br /> concentrations that were greater than five times the blank concentration and were not qualified. <br /> Both samples had TOC detected below the reporting limit and were qualified as non-detects (U) <br /> at the reporting limit. <br /> All data submitted for this project are of known and acceptable quality as qualified, based on laboratory- <br /> established control limits and the data quality objectives. These data are considered acceptable for their <br /> intended purposes. <br /> Summary of Qualified Data: <br /> Sample Name Laboratory ID Sample Parameter Result Unit Qualifier <br /> Date <br /> TW-15 Y2G1811-02 7/18/2012 TOC 1.1 mg/L J <br /> MW-447S Y2G1811-03 7/18/2012 TOC < 1.0 mg/L U <br /> MW-447D Y2G1811-04 7/18/2012 TOC < 1.0 mg/L U <br /> MW-448D Y2G1811-05 7/18/2012 TOC < 1.0 mg/L U <br /> Page 3 of 6 <br />