My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER
>
200
>
2900 - Site Mitigation Program
>
PR0541087
>
ARCHIVED REPORTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2019 7:59:21 PM
Creation date
2/22/2019 3:43:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
RECORD_ID
PR0541087
PE
2959
FACILITY_ID
FA0023524
FACILITY_NAME
SPX MARLEY COOLING FACILITY
STREET_NUMBER
200
Direction
N
STREET_NAME
WAGNER
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
14331007
CURRENT_STATUS
01
SITE_LOCATION
200 N WAGNER AVE
P_LOCATION
01
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
respectively), TDS (23.0 and 33.0 mg/L, respectively), and TOC (1.3 mg/L for both). Both <br /> samples had TOC detected at concentrations that was greater than the reporting limit, but less <br /> than five times the blank concentration, and was qualified as estimated (J). Sulfate and TDS <br /> were detected at concentrations that were greater than five times the blank sample <br /> concentrations, so the results were not qualified. <br /> • Equipment Rinse and Field Blank, collected on October 23, 2012, were associated with the <br /> analysis of five samples and had TOC detected at 0.1 and 0.2 mg/L, respectively. Two samples <br /> had TOC detected below the reporting limit and were qualified as non-detects (U) at the reporting <br /> limit. <br /> • Equipment Rinse and Field Blank, collected on October 24, 2012, were associated with the <br /> analysis of one sample and had TOC detected at 0.4 and 0.3 mg/L, respectively. Additionally, <br /> Equipment Rinse had TDS detected 5.0 mg/L. TOC was detected in the sample at a <br /> concentration that was greater than the reporting limit, but less than five times the blank <br /> concentration, and was qualified as estimated (J). TDS was detected in the sample at a <br /> concentration that was greater than five times the blank result, and therefore was not qualified. <br /> • Equipment Rinse and Field Blank, collected on October 25, 2012, were associated with the <br /> analysis of five samples and had TOC detected at 0.7 mg/L in both. Four samples had TOC <br /> detected below the reporting limit and were qualified as non-detects (U) at the reporting limit. The <br /> fifth sample had TOC detected at a concentration that was greater than five times the blank <br /> result, and therefore was not qualified. <br /> • Equipment Rinse and Field Blank, collected on October 29, 2012, were associated with the <br /> analysis of one sample and had TOC detected at 0.5 and 0.4 mg/L, respectively. TOC was <br /> detected below the reporting limit and was qualified as a non-detect(U)at the reporting limit. <br /> • One method blank associated with the TDS analysis of 16 samples collected October 23, 2012, <br /> contained 5 mg/L of TDS. TDS was detected all associated samples at concentrations that were <br /> greater than five times the blank result, so no data were qualified. <br /> All data submitted for this project are of known and acceptable quality as qualified, based on laboratory- <br /> established control limits and the data quality objectives. These data are considered acceptable for their <br /> intended purposes. <br /> Summary of Qualified Data: <br /> Sample Name Laboratory Sample Parameter Result Unit Qualifier <br /> ID Date <br /> EW-1 Y2J2203-01 10/22/2012 TOC 1.6 mg/L J <br /> EW-1 Y2J2203-01 10/22/2012 Dissolved Iron 1.50 mg/L J <br /> EW-1 Duplicate Y2J2203-05 10/22/2012 TOC 1.7 mg/L J <br /> MW-303 Y2J2318-14 10/23/2012 TOC 2.3 mg/L J <br /> TW-14 Y2J2318-15 10/23/2012 Dissolved 0.001 mg/L J <br /> Arsenic <br /> TW-13 Y2J2318-20 10/23/2012 TOC < 1.0 mg/L U <br /> TW-14 Dup Y2J2318-22 10/23/2012 TOC < 1.0 mg/L U <br /> TW-15 Y2J2418-11 10/24/2012 TOC 1.2 mg/L J <br /> MW-321 (1-9) Y2J2504-01 10/25/2012 Sulfate 24.3 mg/L J <br /> MW-321 (1-9) Y2J2504-01 10/25/2012 TOC 12 mg/L J <br /> 1-11 Y2J2504-05 10/25/2012 TOC < 1.0 mg/L U <br /> Page 3 of 6 <br />