Laserfiche WebLink
I <br /> Lancaster Laboratories <br /> Where(I(jali t y is t) sno x r <br /> Page ) of 2 <br /> Lancaster Laboratories Sample No. WW 3900372 <br />' Collected: 09/13/2002 14 : 33 by DM Account Number: 10869 <br /> Submitted: 09/17/2002 09: 10 ChevronTexaco <br />' Reported: 10/04/2002 at 15:46 6001 Bollinger Canyon Rd L4310 <br /> Discard: 11/04/2002 San Ramon CA 94583 <br /> MW-11-W-020913 NA Water <br /> Facility# 90557 SIRC <br />' 139 S Center St-Stockton T0607700391 MW-11 <br /> SCS11 <br />' As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRO - Waters n.a. N.D. 50. ug/l 1 <br />' The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> starttime. <br /> A site-specific MSD sample was not submitted for the project. A LCS/LCSD <br />' was performed to demonstrate precision and accuracy at a batch level. <br /> 05553 TPH - DRO CA LUFT (Waters) n.a. N.D. 50. ug/l 1 <br /> According to the California LUFT Protocol, the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our #2 fuel oil reference standard (between C10 and C28 normal <br />' hydrocarbons) . <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br />' 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N.D. 200. ug/1 1 <br /> Due to a laboratory error, the sample was analyzed past the method hold <br />' time. <br /> 02500 TPH Fuels by GC (Waters) <br />' 02501 Total TPH n.a. N.D. 200. ug/l 1 <br /> 02508 TPH Motor Oil C16-C36 n.a. N.D. 400. ug/1 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br />' CS (n-octane) through C40 (n-tetracontane) normal hydrocarbons. <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br />' 01594 BTEX + Oxygenates by 8260E <br /> 01587 Ethanol 64-17-5 N.Q. 50. ug/1 1 <br /> 02010 Methyl t-butyl ether 1634-04-4 1. 0.5 ug/1 1 <br />' 02011 di-Isopropyl ether 108-20-3 N.D. 0.5 ug/1 1 <br /> 02013 Ethyl t-butyl ether 637-92-3 N.D. 0.5 ug/1 1 <br /> 02014 t-Amyl methyl ether 994-05-8 N.D. 0.5 ug/1 1 <br /> 02015 t-Butyl alcohol 75-65-0 N.D. 5. ug/l 1 <br />' 05401 Benzene 71-43-2 N.D. 0.5 ug/1 1 <br /> 05402 1,2-Dichloroethane 107-06-2 N-D. 0.5 ug/l 1 <br /> 5407 Toluene 108-88-3 N-D. 0.5 ug/l 1 <br /> 5412 1,2-Dibromoethane 106-93-4 N.D. 0.5 ug/1 1 <br />' 05415 Ethylbenzene 100-41-4 N.D. 0.5 ug/l 1 <br /> Lancaster Laboratories,Inc. <br /> 1` PA E3 E R 2425 New Holland Pike <br /> PQ Fiox 11425 <br /> sn�a•.lei.PA 1/F>>;1;2415 <br /> 2+p0 F,,. 117 Wl(6 ?1181 <br />