Lancaster Laboratories <br /> h Where quality is a science. <br /> IPage 1 of Z <br /> Lancaster Laboratories sample No. WW 3937824 <br /> Collected: 11/07/2002 15:35 by DM Account Number: 10869 <br /> Submitted: 11/11/2002 09:30 ChevronTexaco <br />' Reported: 11/25/2002 at 19:51 6001 Bollinger Canyon Rd L4310 <br /> Discard: 12/26/2002 San Ramon CA 94583 <br /> MW-9S-W-021107 NA Water <br /> Facility# 90557 SIRC <br />' 139 S Center-Stockton T0607700391 MW-9S <br /> SC-9S <br />' As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRO - Waters n.a. 120,000. 2,500. ug/l 50 <br />' The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time. <br /> 05553 TPH - DRO CA LUFT (Waters) n.a. 36,000. 1,300. ug/l 50 <br />' According to the California LUFT Protocol, the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our #2 fuel oil reference standard (between C10 and C28 normal <br /> hydrocarbons) . <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br />' was performed to demonstrate precision and accuracy at a hatch level- <br /> 01412 Methanol and Ethanol <br />' 01414 Methanol (by Direct Injection) 67-56-1 N-D. 200. ug/l 1 <br /> 02500 TPH Fuels by GC (Waters) <br />' 02501 Total TPH n.a. 8,600. 800. ug/,l 1 <br /> 02508 TPH Motor Oil C16-C36 n.a. 8,600. 800. ug/l 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br />' C8 (n-octane) through C40 (n-tetracontane) normal hydrocarbons. <br /> Site-specific MS/MSA samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> Due to matrix interference, accurate chlorobenzene surrogate recovery <br />' could not be determined. <br /> Due to interferences from the sample matrix (high sediment content) , the <br />' reporting limit was increased. <br /> 01594 RTEX * Oxygenates by 82605 <br />' 01587 Ethanol 64-17-5 N.Q. 500. ug/l 10 <br /> 02010 Methyl t-butyl ether 1634-04-4 N.D, 5- ug/l 10 <br /> 02011 di-isopropyl ether 108-20-3 N.D. 5. ug/l 10 <br /> 02013 Ethyl t-butyl ether 637-92-3 N.D- 5- ug/l 10 <br />' 02014 t-Amyl methyl ether 994-05-8 N-D. S. ug/l 10 <br /> 02015 t-Butyl alcohol 75-65-0 330. 50. ug/l 10 <br /> 05401 Benzene 71-43-2 9,700. 50- ug/1 100 <br /> 5402 1,2-Dichloroethane 107-06-2 180- 5. ug/1 10 <br />' 05407 Toluene 108-88-3 12,000. 50. ug/l 100 <br /> Lancaster Laboratories,Inc. <br /> M' E� 2425 New Holland Pike PO Box 12425 <br /> Lancaster,PA 17605.2425 <br /> 717-656-2300 Fax:717-656-2681 2216 R,,9/11100 <br />