Laserfiche WebLink
Lancaster <br /> A Laboratories <br /> Page ] of 2 <br /> Lancaster Laboratories Sample No. WW 3975843 <br /> Collected:01/03/2003 13 :50 by DM Account Number: 10906 <br /> Submitted: 01/09/2003 09:45 ChevronTexaco <br /> Reported: 01/27/2003 at 10 :52 6001 Bollinger Canyon Rd L4310 <br /> Discard: 02/27/2003 San Ramon CA 94563 <br /> MW-11-W-030103 Grab Water <br /> Facility# 90557 job# 386843 GRD <br /> 139 South Center St T0607700391 MW-11 <br /> CEN11 <br /> AS Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01726 TPH-GRO - Waters n.a. N.D. 50. ug/l 1 <br /> The reported concentration of TPH-GRo does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time. <br /> A site-specific MSD sample was not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> ID5553 TPH - DRO CA LUFT (Waters) n.a. 140- 50. ug/l 1 <br /> According to the California LUFT Protocol, the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our 42 fuel oil reference standard (between C10 and C26 normal <br /> hydrocarbons) . <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> A significant amount of the DRO result is from non-petroleum organic <br /> material. <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N.D. 1,000. ug/l 1 <br /> 02500 TPH Fuels by GC (Waters) <br /> 02501 Total TPH n.a. N.D. 400. ug/l 1 <br /> 02508 TPH Motor Oil C16-C36 n.a. N.D. 400. ug/l 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C8 (n-octane) through C40 (n-tetracontane) normal hydrocarbons. <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 01594 BTEX + oxygenates by 8260B <br /> 01587 Ethanol 64-17-5 N.D. 500. ug/l 1 <br /> 02010 Methyl t-butyl ether 1634-04-4 N.D. 2. ug/l 1 <br /> 02011 di-Isopropyl ether 108-20-3 N.D. 2. ug/l 1 <br /> 2013 Ethyl t-butyl ether 637-92-3 N.D. 2. ug/l 1 <br /> #=Laboratory MethodDetection Limit exceeded target detection limit <br /> N.D.=Not detected at or above rtaa 0AingdAiWit,c. <br /> M E M B E FS 2425 New Holland Pike <br /> PO Box 1 <br /> � Lancasterr,,PA PA 17605-2425 <br /> 717-656-2300 Fax:717-656-2681 <br />