Laserfiche WebLink
I <br /> I <br /> i <br /> Lancaster <br /> • a Laboratories <br /> Page 7 of 7 <br /> Quality Control Summary <br /> Client Name: ChevronTexaco Group Number: 837315 <br /> Reported: 01/27/03 at 10 :52 AM <br /> Surrogate Quality Control. <br /> Batch number: 9030121AA <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 3975837 102 99 97 92 <br /> 3975838 97 96 98 97 <br /> 3975839 97 96 95 99 <br /> 3975841 95 93 94 99 <br /> 3975842 99 98 96 94 <br /> 3975843 101 99 96 94 <br /> 3975844 101 101 95 93 <br /> Blank 101 96 96 93 <br /> LCS 98 98 99 101 <br /> MS 97 99 99 102 <br /> MSD 97 98 99 100 <br /> Limits: 86-11B 80-120 88-110 86-115 <br /> Analysis Name: BTEX + Oxygenates by 8260E <br /> Batch number: N030121AB <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 75840 97 98 99 100 <br /> Blank 96 96 98 96 <br /> LCS 98 98 99 101 <br /> MS 97 99 99 102 <br /> MSD 97 98 99 100 <br /> Limits: 86-118 80-120 88-110 86-115 <br /> *- Outside of specification <br /> The result for one or both determinations was less than five times the LOQ. <br /> The background result was more than four times the spike added. <br /> Lancaster Laboratories,Inc. <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> ® 717-6 <br /> Lancaster,6-2300 17605-2425 <br /> Fax:717-6 <br /> 717-656-2300 Fax:717-656-2681 <br />