Laserfiche WebLink
Lancaster Laboratories <br /> • Where quality is a science. <br /> Pagc 1 of 3 <br /> Lancaster Laboratories Sample No. WW 3007004 <br /> Collected:04/16/2002 14:35 by TC Account Number: 10906 <br /> Submitted: 04/18/2002 08:55 Chevron Products Company <br /> Reported: 05/01/2002 at 12:26 6001 Bollinger Canyon Rd <br /> Discard: 06/01/2002 Building L PO Box 6004 <br /> MW-2-W-020416 Grab Water San Ramon CA 94583-0904 <br /> Facility# 90557 Job# 386843 GRD <br /> 139 S CENTER-STOCKTON 70607700391 MW-2 <br /> 557M2 <br /> As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Unite Factor <br /> Limit <br /> 05553 TPH - DRO CA LUFT (Waters) n.a. 550. 50. ug/l 1 <br /> According to the California LUFT Protocol, the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our #2 fuel oil reference standard (between C10 and C28 normal <br /> . hydrocarbons) . <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N.D. 1,000. ug/l 1 <br /> 01729 TPH-GRO - Waters <br /> 01730 TPH-GRO - Waters n.a. N.D. 50. ug/1 1 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time. <br /> A site-specific MSD sample was not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 02500 TPH Fuels by GC (waters) <br /> 02501 Total TPH n.a. N.D. 11000. ug/l 1 <br /> 02508 TPH Motor Oil C16-C36 n.a. N.D. 1,000. ug/l 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C8 (n-octane) through C40 (n-tetracontane) normal hydrocarbons. <br /> The sample was acid preserved for the TPH analysis at the time of <br /> extraction. <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 8214 BTEX, MTBE (8021) <br /> #--Laboratory MethodDetec{tJ n �Ldrrarget detection limit <br /> N.D=Not d oW ortmg�imit <br /> Lancaster,PA 17645-2425 <br /> 717-656-2300 Fax:717-656-2681 2216 Rev.9111/00 <br />