Yepcl <br /> � f <br /> Lancaster Laboratories <br /> 6 Where quality is a science. <br /> Page 1 of 3 <br /> Lancaster Laboratories Sample No. WW 3807014 <br /> Collected:04/15/2002 15:47 by TC Account Number: 10906 <br /> Submitted: 04/18/2002 08:55 Chevron Products Company <br /> Reported: 05/01/2002 at 12:28 6001 Bollinger Canyon Rd <br /> Discard: 06/01/2002 Building L PO Box 6004 <br /> MW-10-W-020415 Grab Water San Ramon CA 945B3-0904 <br /> Facility# 90557 Job# 386843 GRD <br /> 139 S CENTER-STOCKTON 70607700391 MW-10 <br /> 55710 <br /> As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 05553 TPH - DRO CA LUFT (Waters) n.a. 1,400. 50. ug/l 1 <br /> According to the California LUFT Protocol, the quantitation for Diesel <br /> Range organics was performed by peak area comparison of the sample pattern <br /> to that of our #2 fuel oil reference standard (between C10 and C28 normal <br /> hydrocarbons) <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N.D. 1,000. ug/l 1 <br /> 01729 TPH-GRO - Waters <br /> 01730 TPH-GRO - Waters n.a. 770. 50. ug/l 1 <br /> The reported concentration of TPH-GAO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time. <br /> A site-specific MSD sample was not: submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level- <br /> 02500 TPH Fuels by GC (Waters) <br /> 02501 Total TPH n.a. N.D. 1,000. ug/l 1 <br /> 02508 TPH Motor Oil C16-C36 n.a. N.D. 1,000. ug/l 1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C8 (n-octane) through C40 (n-tetracontane) normal hydrocarbons. <br /> The sample was acid preserved for the TPH analysis at the time of <br /> extraction. <br /> Site-specific MS/MSD samples were not submitted for the project. A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level. <br /> 16214 BTEX, MTBE (8021) <br /> #--Laboratory MethodDetec 5lfi� F bdr%rget detection limit <br /> N.D.=Not o � H°or[uig unit <br /> Lancaster,PA 17605-2425 <br /> 717-656-2300 Fax:717-656-2681 2216 Rev.9111l00 <br />