Laserfiche WebLink
Client Number: 020703983 <br /> Consultant Protect Number: 020703983 <br /> Facility Number: 5-0557 <br /> Project ID: 139 South Center St. <br /> Stockton,CA <br /> Work order Number: C348-0257 <br /> Table 1 <br /> ANALYTICAL RESULTS <br /> Aromatic Volatile Organics and <br /> Total Petroleum Hydrocarbons as Gasoline in Water <br /> EPA Methods 5030, 8020, and Modified 8015a <br /> GTEL Sample Number 01 02 03 05 <br /> Client Identification TS LB RBMW5 MW5 MW4 <br /> Date Sampled 08/17/93 08/17/93 08/17/93 08/17/93 <br /> Date Analyzed 08/24/93 1 08/25/93 1 08/25/93 1 08/25/93 <br /> Detection <br /> Analyte Limit, ug/L Concentration, ug/L <br /> Benzene 0.5 <0.5 <0.5 1 <0.5 <br /> Toluene 0.5 <0.5 <0.5 <0.5 <0.5 <br /> Ethylbenzene 0.5 <0.5 <0.5 0.9 <0.5 <br /> Xylene, total 0.5 <0.5 <0.5 0.8 <0.5 <br /> BTEX, total -- -- -- 3 -- <br /> TPH as Gasoline 50 <50 <50 145 <50 <br /> Detection Limit Multiplier 1 1 1 1 <br /> BFB surrogate, % recove 93.7 87.8 98.9 84.1 <br /> a. Test Methods for Evaluating Solid Waste,SW-846,Third Edition,Revision 0, US EPA November 1986. Modification for TPH as <br /> gasoline as per California State Water Resources Control Board LUFT Manual protocols, May 1988 revision. Bromofluorobenzene <br /> surrogate recovery acceptability limits are 70-130%. <br /> GTEL Concord,CA GTE <br /> L <br /> C3080257,BXG <br /> E VVIR 0 IJf N T A L <br /> IIIIIIIIIIIIIIi LARORAIORIES. IHC <br />