My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0011671
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
221
>
2900 - Site Mitigation Program
>
PR0506624
>
ARCHIVED REPORTS XR0011671
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2019 12:45:57 PM
Creation date
2/25/2019 11:15:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011671
RECORD_ID
PR0506624
PE
2950
FACILITY_ID
FA0007549
FACILITY_NAME
WEBER POINT SEAWALL
STREET_NUMBER
221
Direction
N
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
221 N CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> 16 11 Describe important on-site and/or adjacent topographical and water features <br /> On-Site The existing seawall is approximately 3 ft wide and 835 ft long There are no inivortant topographical features <br /> associated with this structure <br /> Adjacent The existing seawall is located immediately ad ai cent to the Stockton Channel <br /> 12 Describe any important on-site and/or adjacent vegetation/wildlife habitat <br /> On-Site There is no vegetation or wildlife habitat of importance on-site <br /> Adjacent There is no vegetation or wildlife habitat of importance ad acent to the Droject study area <br /> ' 13 Describe any general and special status wildlife species known to inhabit the site or for which the site provides important <br /> habitat The existmg seawall is located unmediately adiacent„to Stockton Channel Since the Weber Point Southbank <br /> ' Seawall prosect occurs within the boundaries of the legal Delta, the project is located within an area considered as <br /> Critical Habitat for Delta smelt See Appendix B, "Biological Fishenes Resources Evaluation and Wetland <br /> Delineation Report”(Sycamore Environmental, 1997) for additional discussion The habitat assessment demonstrates a <br /> lack of suitable foraging.and spawning habitat for.Delta smelt and other aquatic species of potential concern including <br /> ' Sacramento solittail,Green sturgeon,River lamprey,.and Pacific lamprey <br /> 14 Identify and describe any significant cultural resources on or near the site (attach a "Records Search," "Site Survey," <br /> and/or other documentation, if applicable) See Section IV_19 of this IS,and Appendix B,pages 13 and 15 <br /> 15 Identify and describe any on-site or nearby public health and safety hazards or hazardous areas (attach a "Preliminary <br /> Site Assessment" and/or "Remediation Plan," if applicable) A small_void currently exists beneath the existing seawall <br /> This void presents a safety hazard because of the potential for collapse of portions of the seawall „There are no other known <br /> public health and safety hazards or hazardous areas within the protect study area <br /> l6 Identify and describe any potentially hazardous geologic/soil conditions Underground drams and pipes occur throughout <br /> and beneath the site Due to the age of the pipes, they ma have asbestos-contamm materials lemfelder, 14 July 1997 <br /> ' Preliminary Environmental Site Assessment) The site is listed on the ERN regulatory agency database list and the <br /> California facility inventory database as a site with a reported hazardous incident The incident that occurred was an <br /> asbestos spill <1 ound which was cleaned uR and transported to a waste facilLty in accordance with San Joaquin County <br /> ' guidelines _ <br /> 17 Is any portion of the site subject to a 100-year flood? Yes X No <br /> ' If so, identify and describe the flood zone designation(s) for the site(as shown on the Federal Emergency Management <br /> Agency's Flood Insurance Rate Maps) Zone X,less than 1 ft inundation _ <br /> ' <br /> 18 Identify and describe any existing and/or projected on-site ambient noise levels which exceed adopted noise standards <br /> (plot those noise contours on proposed tentative maps and/or on a site plan for the project,as applicable) <br /> ' a Do on-site ambient noise levels from existing land uses(locally regulated noise sources)located on-site or off-site <br /> exceed adopted noise standards9 Yes No X <br /> If so,describe <br /> ' b Does or will transportation-related noise exceed 60 dB Ldn/CNEL at any exterior location or 45 dB Ldn/CNEL at <br /> any interior location9 Yes No X <br /> If so,describe <br /> FX IS 04 DOC 925/97 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.