k:,4/10/2015 7: 10A4 FAX 19259 371 Guadalupe Sanchez f�0001/0015 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> .Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A e i1f!r[' f or re ort must be prepared for each <br /> monitoring m control partel by the tc n e rk. A cT3§j to the tank system owner/operator. <br /> The owner'/operator must submit a Copy to 41 n ul9;q W,jr%jNV"cd <br /> 30 days of test date. <br /> A. General Information APR 10 2015 S��Z j dad <br /> Facility Name: ARP Mini Mart 76 A Bldg.No.. <br /> Site,Address: 25775 So. Patterso Iritah—PhoT!N <br /> Zip: 95376 <br /> Facility Contact Person: Neil Patel ,T�4 co pT��C�to.: (510) 299-1219 <br /> MakefModel of Monitoring System: Veede`r Root TLS-350 Datta ofTesting/Servicing: 3/1012015 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indieste specific c ui ment inspected/serviced: <br /> Tank TD: T1: 87 Slave Tank ID: T2: 87 Master <br /> Z In-Tank Gauging Probe, Model: 847390-107 M In-Tank Gauging Probe. Model: 847390-107 <br /> Annular Space or ,Vault Sensor, Model: 794390-407 Z Annular Space or Vault Sensor, Model; 794390-407 <br /> N Piping Sump/Trench Sensor(s). Model- 794380-208 M Piping Sump/Trench Sensor(s). Model: 794380.208 <br /> ®Pitl Sump Scnsor(s), Model: 794380-208 ®Fill Sump Scnsor(s), Model: 794380-208 <br /> ❑Mechanical Line Leak Detector, Model: ❑Mechanical Line Leak Detector, Model; <br /> ❑Electronic Line Leak Detector. Model: M Electronic Line Leak Detector. Model: 8484 <br /> ❑Tank Overfill/High-Lcvcl Sensor. Model: ❑Tank Ovcrfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2), ❑Other(specify equipment typo and model in Section E on Page 2). <br /> Tank 1D: T3: 87 Siphon Tank w: T4: 91 <br /> N Li-Tank Gauging Probe. Model: 847390-107 M hi-Tank Gauging Probe, Model: 848390-107 <br /> N Annular Space or Vault Sensor. Model: 794390407 Z Annular Space or Vault Scnsor, Model; 794390-407 <br /> M Piping Sump/-french Scnsor(s), Model: 794380-208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ®Fill Sump Sensor("). Model: 794380-208 M Fill Sump Sensor(s). Model: 794380-208 <br /> �]Mechanical Line Leak Detector. Model; 0 Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: M Electronic Line Leak Detector. Model: 8484 <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor, Model; <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Othcr(specify equipment type and model in Section F on Page 2), <br /> Dispenser ID: 1&2 Dispenser ID: 3&4 <br /> N Dispenser Containment Sensor(s). Model: 794380-208 M Dispenser Containment Scnsor(s). Model: 794380-208 <br /> N Shear Valvc(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Flont(s)and Chain("), ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5&6 Dispenser ID: 7&8 <br /> Z Dicpen"er Containment Sensor(s), Model: 794380-208 M Dispenser Containment Sensor(s). Model: 794380-208 <br /> M Shear Vulve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispcnser Containment Fluat(s)and Chain("), <br /> Dlspensor ID' Dispenser ID: <br /> ❑1.)ispcnscr Containmcnt Scnsor(s). Model: 0 Dispenser Corttainment Semor(s), Model; <br /> ❑Shear Valve("). Q Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Flost(s)and Chain(s), <br /> ,1I17the facility contains more tanks or dispensers,'copy this form. Include information for every tank and dispenser at the facility, <br /> C. Certification -1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layoutof monitoring a uipment. For any eq un ment capable of generating such reports,i have also <br /> attached a copy of the report;(check all that apply): System set-up Alarm history report <br /> Technician Name(print): Guadalupe Sanchez Signature - --Z/ — <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services, Inc. Phone No-:(209) 845-8586 <br /> Testing Company Address: 11930 Horseshoe Rd.Oakdale,Ca.95361 Date ouresting/Servicing: 3/10/2015 <br /> Page 1 of 4 <br /> Rev(2/08) <br />