Laserfiche WebLink
Madison Industries <br />Customer: Mobil Fueling Canopy <br />Designed by: ML/JFB <br />Structure: 65'-0" x 54'-4" (4) Column Canopy <br />August 4, 2016 <br />Location: Tracy, CA 95377 <br />Job No: WCA17860-1 <br />Sheet 19 <br />Roof Support Beam BZ cont. <br />Design Strengths - Span: <br />For Lb<Lp : <br />Top Flange: ObM"' = 124.5 ft-k <br />N/A this case <br />Bottom Flange: ObMn" = 124.5 ft-k <br />Governs for bottom flange <br />Where: = 0.9 <br />Mn = lesser of: 1) M = FyZX = 138 ft-k <br />2) 1.5My = 1.5FySX = 181 ft-k <br />For Lp<Lb<Lr : <br />Top Flange: ObMn' = 93.3 ft-k <br />Governs for top flange <br />Bottom Flange: ObMn" = 135.0 ft-k <br />N/A this case <br />Where: 0 = 0.9 <br />Mn' = Cb(MP (Mp-Mr)I(Lb'-Lp)/(Lr Lp)]} = 103.7 ft-k,- <br />Mn" = Cb(Mp--(Mp-Mr)((Lb"-Lp)/(Lr Lp)]} = 150.0 ft-k <br />Cb= 1.0 <br />JUN 0 8 2017 <br />Mr = FLS. = 96.7 ft-k <br />For Lb>Lr: <br />Top Flange: ObMn' = 105.7 ft-k <br />N/A this case <br />Bottom Flange: ObMn" = 1765 ft-k <br />N/A this case <br />Where: = 0.9 <br />M,,'= Mcr =(CbSxX1(2)12/(Lb'/ry)](1+X12X2/[2(Lb'/ry)2]]112 = <br />117 ft-k <br />Mn" = Mr" = (CbSXX1(2)112/(Lb"/ry)](1+X12X2/[2(Lb' /ry)2]]1/2 = <br />1961 ft-k <br />Design Strengths - Cantilever: <br />For Lb<Lp : <br />Top Flange: ObMn' = 124.5 ft-k <br />N/A this case <br />Bottom Flange: ObMn" = 124.5 ft-k <br />Governs for bottom flange <br />For Lp<Lb<Lr <br />Top Flange: ObMn' = 59.0 ft-k <br />N/A this case <br />Bottom Flange: ObMn" = 135.0 ft-k <br />N/A this case <br />Where: = 0.9 <br />M,'= Cb{Mp-(Mp-Mr)I(Lb'-Lp)/(Lr Lp)]) = 65.5 ft-k <br />Mn" = Cb(Mp-(Mp-Mr)((Lb"-Lp)/(Lr Lp)]) = 150.0 ft-k <br />For Lb>Lr: <br />Top Flange: 4Mn' = 46.3 ft-k <br />Governs for top flange <br />Bottom Flange: ObMn" = 1765 ft-k <br />N/A this case <br />Where: = 0.9 <br />Mn' = Mcr = ICbS.X1(2)1/2/(Lbs/ry)]I1+X12X2/[2(Lb'/ry)2]]1/2 = <br />51 ft-k <br />Mn" = Mcr " = [CbS.X1(2)U2/(Lbs /r )][1+X12X2/[2(Lb' /ry )2]]1/2 = <br />y <br />1961 ft-k <br />