My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 2:13:59 PM
Creation date
2/26/2019 12:07:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
506
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Madison Industries <br />Designed by: ML/JFB <br />August 4, 2016 <br />Job No: WCA17860-1 <br />Customer: Mobil Fueling Canopy <br />Structure: 65'-0" x 54'-4" (4) Column Canopy <br />Location: Tracy, CA 95377 <br />Roof Support Girder G1, cont. <br />Sheet 26 <br />Factored Service Load Moments: <br />Bottom flanges cantilever & span in compression: <br />Case 1: Full DL + LL over entire beam -- Checks critical negative bending in span & cantilever <br />M"„(cant) = Mu"(span) = (Wu2)a2/2 + (P1u2)(a) +(P2u2)(b) = 249 ft -k <br />Top flange span in compression: <br />Case 2: Full DL + LL over span; DL only on cantilever -- Checks critical positive bending in span <br />Case 2A: Actual loads <br />Mu'(span) = (P3u2)(C) + (Wu2)L2/8 - (0.9WDL)(a2)/2 - (P1A(a) - (P2.3)(b)= 9.2 ft -k <br />Case 213: For roof members <br />Is this a roof member? (y/n) y <br />Mu'(span) =(P3ut)(c)+(wu1)L2/8-(0.9WDL)(a2)/2-(P1u3)(a)-(P2u3)(b)+P'U4 = -26.4 ft -k <br />Where P'= (1.4)(200 lbs) if tributary area < 200 ft2 or <br />(1.4)(2000 lbs) per UBC 1994 Section 1605.2.3 <br />Factored moment for design of span top flange = M,,'(span) = 9.2 ft -k <br />Bottom flange span & top flange cantilever in compression: <br />Case 3: Full DL + WIND UPLIFT over entire length -- Checks crit. neg. bending stress in span <br />& crit. pos. bending stress in cantilever <br />mull <br />l(span) _ (Wu3)L2/8 - (P30)(C) = <br />Mu'(cant) = (Wu3)a2/2 - (P100) - (P200) = <br />Factored service load design moments: <br />Top flange span in compression: <br />Bottom flange span in compression: <br />Top flange cantilever in compression: <br />Bottom flange cantilever in compression <br />Unbraced Length Limits: <br />Lp = 300ry/sgrt(Fy) = <br />L, = ryXt/Ft_(1+sgrt(1+X2FL2))1/2 = <br />Where: Xt = (7E/Sx)(EGJA/2)1/2 = <br />X2 = (4Cw/ly)(Sx/GJ)2 = <br />FL=(Fy-10)= <br />Mu (span) = <br />Mu (span) = <br />Mu (cant) = <br />Mu (cant) = <br />5.9 ft <br />16.15 ft <br />2112 <br />0.009 <br />40 ks i <br />29.7 ft -k <br />39.7 ft -k <br />9.2 ft -k <br />249.2 ft -k <br />39.7 ft -k <br />249.2 ft -k <br />JUN 0 8 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.