Laserfiche WebLink
OPW 10 SERIES EMERGENCY SHUT-OFF VALVES <br /> OPW 10 Series Emergency Shut-off Valves are installed on fuel supply Patented Thermal <br /> lines beneath dispensers at grade-level to minimize hazards associated with Low Profile Relief Valve <br /> collision or fire at the dispenser. if the dispenser is pulled over or dislodged <br /> by collision,the top of the valve breaks off at the integral shear groove, air rest <br /> Main Port <br /> activating poppets and shutting off the flow of fuel.Single-moppet models Poppet Seat <br /> shut off supply flow,while double-poppet models shut off supply as well as secondary <br /> prevent release of fuel from the dispenser's internal piping.The base of the Poppet <br /> Emergency Valve is securely anchored to the concrete dispenser island <br /> through a stabilizer bar system within the dispenser sump or pan to ensure Fusible Link <br /> proper shearing action.The valve base is secured to the stabilizer bar using Nickel-Plated, <br /> a three-point boss mount system or a U-Bolt Kit(not included);1OUBK-015 sold Teflon-Coated <br /> separately.Valve inlet(bottom)connections are female pipe threads and out CombinatMain stem <br /> ion <br /> let(top)connections are available with female threads,male threads,or a Body <br /> union fitting.Other options include suction system models with a normally Main <br /> closed secondary poppet which maintains prime,and models with external Poppet <br /> threads on the inlet body which connect to secondary containment systems. <br /> Features <br /> ♦High Flow Capacity—The primary ♦Reliable Shut-off—A Stainless ♦Multiple Mounting Options—Valves <br /> poppet is held out of the flow stream Steel Main Spring,a Teflon-Coated are boss-mounted to stabilizer bars in <br /> while the secondary poppet is held Brass Packing Nut,and a Copper- sumps and pans or mounted to bars <br /> normally open to minimize head loss Nickel-Chrome Plated Brass Stem embedded in the island with optional <br /> across the valve and to protect the are designed to prevent tar build-up Ll-Bolt kits 1OUBK-015(not included), <br /> poppet seals from damage and erosion. and corrosion from interfering with Versatile Combination Body(boss <br /> True 1X"and 2" body sizes ensure poppet operation after long periods of mountN-Bolt mount)models are available <br /> maximum flow. normal service without activation. to accommodate most mounting <br /> ♦Fire Protection—A fusible link trips the ♦Integral Test Port—A%"Test Port applications with one valve style. <br /> valve closed at 165°F to shut off fuel allows the piping system to be air-tested ♦Underwriters laboratories— <br /> suppiy to the dispenser. without breaking any piping connections. Listed for use with gasoline and 85% <br /> ♦Main Poppet Seat Integral to the Top ♦Patented Thermal Relief Valve— and 100%methanol.All OPW 10L <br /> Assembly—Having the main poppet Relieves excessive pressure build-up Emergency Shut-Off Valves meet <br /> seat as an integral part of the valve top caused by thermal expansion of fuel requirements of UL STANDARD 842. <br /> assures a new,clean seating surface is in the dispenser piping system in ♦Duragarcr-Coat Finish—Provides <br /> installed each time the top is replaced. the event of fire(double-poppet superior corrosion resistance. <br /> This design also ensures that the models only). <br /> integrity of the seal between the valve ♦Low-Profile Tops—Female and NOTICE: <br /> top and bottom is verified during line Union-top double-poppet valves have a As per NFPA 30A,electrical supply to the <br /> testing and allows full inspection of the low-profile top to allow upgrading from submersible pump must always be <br /> main poppet when the top is removed. OPW single-poppet valves disconnected before servidng meters, <br /> without changing existing piping. dispensers or emergency shut-off valves. <br /> Materials <br /> Top:cast iron* IMPORTANT NOTICE: <br /> Body:cast iron* When mounting the OPW 10 Series Emergency Shut-off Valves,the anchoring system employed <br /> Disc: M-19 must withstand a force greater than 650 ft.pounds per valve. <br /> NFPA Code 30A,Automotive and Marine Service Station Code,requires that the automatic closing <br /> Carrier:zinc-plated steel feature of emergency shut-off valves be checked at least once per year by manually tripping the <br /> Stem:copper-nickel-chrome- hold-open linkage. <br /> plated brass OPW recommends the use of PISCES'Stabilizer Bar Support System for proper mounting of <br /> 10 Series Valves. <br /> Poppet spring:stainless steel <br /> Seal:M-19 O-ring OPW 10S Stabilizer OPW 10RW Wrench <br /> Packing nut: brass,Teflon"-coated gar Assembly The OPW 10RW Wrench is used to install <br /> Inlet and outlet thread: 1'/2"NPT and remove 1X"OPW 10 Series Emergency <br /> The OPW 10S Stabilizer Bar Assembly is used <br /> (British threads available) Shut-off valves and is designed to prevent <br /> *With black Duragard"E-Coating in installations where no valve mounting system stress to the shear section of the valve <br /> exists.When properly imbedded into the island during installation. <br /> Ri J 1� concrete,10S holds the OPW 10 Series valves <br /> ECE1 V E D rigidly in place to assure proper shearing action. This wrench is made of ductile iron and has <br /> The 10S assembly includes all necessary a 1Y"diameter boss for use with a pipe <br /> installation hardware. wrench,and a hole for a X"diameter rod. <br /> DC o 5 2017 Part No. List Price Part No. list Price <br /> VA\ 1RONNIENTAL HEAL` 114770 $75.85 1ORW-4735 $51.10 <br /> I)I•v\1z"r1\IENT 4J <br />