My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:26:33 PM
Creation date
2/26/2019 12:19:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: <br />Time Out: <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />i� . P • Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.slgov.org/ehd <br />Underground Storage Tank Program Service Request Inspection Report <br />Name of Facility: ARP MINI MART CORP <br />Date: 01/10/2018 <br />Address: 25775S PATTERSON PASS RD, TRACY 95376 <br />Requestor: KARLI KARNS, CONFIDENCE UST SERVICES, INC. <br />Telephone: (661) 631-3870 <br />Program Element: 2308 - UST RETROFIT <br />Request #: SR0077233 <br />Inspection Type: 298 - UST RETROFIT REPAIR INSPECTION <br />Onsite Service Technician: John Seykora <br />ICC Service Tech/Installer Exp. Date: 12/21/2019 <br />Manufacturer training: INCON, 01/05/20 <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Onsite to verify conversion frames on each dispenser, verify conversion frame retrofit plate in the under dispenser containment <br />(UDC) 1/2, and 5/6, and verify dispenser footprint contained by the UDC sumps. The installed conversion frames, retrofit plate, <br />and dispenser footprint are adequate. Also verified that any potential product piping leaks can be captured by the UDC, and <br />visually inspected the piping within the dispensers for any product leaks. No product leaks were observed during the visual <br />pipe inspection. <br />Onsite to witness and observe secondary containment test on all four UDC's, and all 87 -product and 91 -product piping. The <br />product piping was testing via vacuum at 5psi. The tests passed. The UDC's were tested via INCON, and passed. Secondary <br />containment testing for the four UDC's, all 87 -product piping, and 91 -product piping is due in 6 months. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br />EH Specialist: AARON HANG <br />EHD 23-01 Rev. 06/30/15 <br />Name and Title: John Seykora, Service Tech <br />Phone: (209) 468-3453 <br />FA0003619 SR0077233 SC298 01/10/2018 <br />Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.