My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS - OZONE PILOT TEST & SEMI-ANNUAL GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
1201
>
2900 - Site Mitigation Program
>
PR0542081
>
ARCHIVED REPORTS - OZONE PILOT TEST & SEMI-ANNUAL GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2019 9:53:41 AM
Creation date
2/27/2019 9:21:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
- OZONE PILOT TEST & SEMI-ANNUAL GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
RECORD_ID
PR0542081
PE
2960
FACILITY_ID
FA0024165
FACILITY_NAME
FERNANDO'S PLACE
STREET_NUMBER
1201
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14716003
CURRENT_STATUS
01
SITE_LOCATION
1201 S CENTER ST
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
264
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM ORDER NO. R5-2011-XXX 5 <br /> ' FERNANDO'S-STOCKTON <br /> SAN JOAQUIN COUNTY <br /> ' Table 2: Analytical Methods <br /> Maximum Practical <br /> Constituent Method' Quantitation Limit(pg/L)2 Frequency <br /> ' Suite A <br /> TPHg GC/MS 50 As indicated in <br /> BTEX, DCA EPA 8260B 0.50 Table 1 <br /> ' Suite B <br /> Metals, dissolved EPA 200.7/200.8' 2.0 <br /> ' Total Chromium EPA 200.8/218.6' 10 <br /> Hexavalent Chromium EPA 7199/218.6' 2.0 <br /> Anion S4 EPA 300.1' 100 As indicated in <br /> ' pH/EC EPA 150.1/120.1' 1-14pH units Table 1 <br /> Ammonia EPA 350.1' 100 <br /> COD EPA 410.4 10,000 <br /> ' Alkalinity EPA 310.1 5,000 <br /> TDS EPA 160.1' 10,000 <br /> ' Or an equivalent EPA Method that achieves the maximum Practical Quantitation Limit. <br /> 2 All concentrations between the Method Detection Limit and the Practical Quantitation Limit shall be reported as an estimated value(J flag). <br /> 3 Dissolved metal analyses include Al,As, Ba, Be, Br, Ca, Cd, Cr, Co, Cu, Fe, K, Hg, Mg, Mn, Mo, Ni,Ag, Na, Pb, Sb,TI, V,W,and Zn and <br /> ' are collected in laboratory-supplied non-preserved container, relinquished to the lab for filtering and preservation prior to analyses. <br /> 4 Anions include: acetate,bromide,bromate, nitrogen, nitrite,sulfate,sulfide,orthophosphate,chlorine,and flouride. <br /> FIELD SAMPLING <br /> ' 3. In addition to the above sampling and analysis, groundwater elevation, electrical <br /> conductivity, DO, ORP, pH, and water temperature will be measured in the field each time a <br /> ' monitoring well is sampled. The sampling and analysis of field parameters is specified in <br /> Table 3. <br /> ' Table 3: Field Sampling Requirements <br /> Parameters Units Type of Sample <br /> ' Groundwater Elevation Feet, NAVD 88 Measurement <br /> Water Temperature Degrees Celsius Measurement <br /> ' Electrical Conductivity uhmos/cm Measurement <br /> Dissolved Oxygen/ORP mg/L and % Measurement <br /> pH - <br /> pH Units (to 0.1 units) Measurement <br /> ' An ozone detection meter (field test instrument) will be used periodically in the breathing <br /> zones inside the remediation equipment area and at each injection wellhead during <br /> ' maintenance and monitoring field activities. Field test instruments (such as those used to <br /> test pH and dissolved oxygen) may be used provided that: <br /> ' 1. The operator is trained in proper use and maintenance of the instruments; <br />
The URL can be used to link to this page
Your browser does not support the video tag.