Laserfiche WebLink
LABORATORY REPORT Kennedy/Jenks/Chilton, Laboratory Division <br /> 303 Second Street, Tenth Floor North <br /> San Francisco, CA 94107 <br /> 415-362-6065 <br /> For: Helmick & Lerner, Inc. Received -- <br /> Attention: Noel Lerner Reported 12/06/90 <br /> Address: 3750 Auburn Blvd., Suite A Quality Control Page <br /> Sacramento, CA 95821 (HLI Job No. 0089002) <br /> Source: ---- <br /> Lab. No.: Method Blank <br /> Sample I.D.: Standard Ottawa and <br /> Matrix: Sand <br /> Depth: <br /> Date Collected: <br /> Time Collected: -- <br /> Collected by: KIJIC <br /> Date Extracted: -- <br /> Date Analyzed: 12/03/90 <br /> Analytical Method: Calif. DHS LU-FT Manual <br /> Analysis Units Analytical Results Det. Lim. <br /> Volatile Petroleum <br /> Hydrocarbons(1) mg/Kg <0.05 0,05 <br /> Comments: Gas chromatographic analysis using flame ionization detection. Commercial hydrocarbons used <br /> as comparison standards. Results reported in milligrams per kilogram, wet(as received)weight basis. <br /> (1) By purge and trap, quantitated using gasoline response factor. <br /> Analyst Lynn Perrine Manager <br /> This report applies only to the sample investigated and is not necessarily indicative of the quality of apparently identical or similar samples. The liability <br /> of the laboratory is limited to the amount paid for the report by the issues. The issueassumes all liability for the further distribution of this report or its <br /> contents and by making such distribution agrees to hold the laboratory harmless agai st all claims of persons so informed of the contents hereof. <br />