Laserfiche WebLink
REFLECTED CEILING PLAN NOTES <br /> A. SEE SHEET A001 FOR SYMBOLS. <br /> B. VERIFY LOCATIONS OF HANGING DEPARTMENT SIGNS <br /> WITH TARGET'S IN STORE MARKETING. LOCATIONS <br /> SHOWN ARE FOR REFERENCE ONLY 6 <br /> A501 S1 <br /> C. ACT CEILING GRIDS ARE CENTERED IN ROOMS PER <br /> SPECIFICATION 09 5100 CRITERIA UNLESS NOTED <br /> OTHERWISE <br /> 1 2 3 4 5 6 7 8 9 10 11 D. PROVIDE SLIP <br /> CONNECTION-SEE WALLS EXTENDING <br /> TO ROOF OR STRUCTURETARGET® <br /> A501 TYP <br /> 1000 NICOLLET MALL <br /> E. PROVIDE QUANTITY AND LOCATION OF DIRECTIONAL/ MINNEAPOLIS, MN 55403 <br /> EXIT SIGNS AS REQUIRED BY FIRE MARSHAL HAVING <br /> JURISDICTION <br /> F. REFER TO ELECTRICAL/MECHANICAL FOR LIGHT <br /> FIXTURE AND DIFFUSER RELOCATION. COORDINATE <br /> I I I I I I I I I I <br /> FOR REMOVAL/REUSE OF LIGHTS, DIFFUSERS AND <br /> SPRINKLER HEADS <br /> G. FOR ALIGNMENT OF SPRINKLER IN SALES FLOOR CEILING <br /> SEE SPEC, DIV 21 <br /> H. FOR CEILING GRID BRACING AND EDEGE CONDITIONS IN <br /> SEISMIC DESIGN CATEGORY-SEE 2 3 4 I LI <br /> I I I I I I I I I I I A131 A131 A131 <br /> V <br /> I I I I I I I I I I I <br /> CEILING LEGEND <br /> I I I I I I I I I I I <br /> (E)ACT NEW ACT <br /> 138A I I I CEILING CEILING <br /> K - - - - - - - - - - ----- - - --_ - - ---- ---- - - - - - - - BD130 <br /> 117 I CEILING CEILING <br /> I 138 142 <br /> 461 FROM ROAD PARAMOS, NJ 07652 <br /> TI973.253.9393 WWW.SARGARCH.COM <br /> 140 <br /> I FOR DBL POST OPTIONS <br /> ------- --- ------ I 139 I I <br /> 133 1 184 1sz Iso 1s1 1a7 SECURE BENT FLANGE REVISIONS <br /> las I TO OR #8 SMS @ 16"OC DATE N0. DESCRIPTION <br /> I �� I DECK W/(2)#8 SMS 01117119 ISSUED FOR PERMIT <br /> I OPEN STRUCTURE <br /> USE 25OS162-33 STL COMPRESSION POST <br /> OVER TO FORM 90° <br /> I I I 1s3 I I I I CUT FLANGE AND FOLD <br /> 185 I TERMINATION. SECURE <br /> 2" LENGTHS LESS THAN Y-0". FIRST POST <br /> 131 <br /> � OPEN STRUCTURE <br /> @MAX 12'-0"OC(EA WAY)SPACING FOR <br /> -141 I W/#8 SMS EA �' LOCATED WITHIN 6'-0"OF EACH WALL <br /> FLANGE <br /> x I, USE DOUBLE 250S162-33 STL COMPRESSION <br /> POST @ MAX 12'-0"OC(EA WAY)SPACING <br /> lose _ � I FOR LENGTHS BETWEEN 9'-0"AND 14'-0" <br /> I <br /> 2 o • o 0 0 <br /> I SEE ABOVE FOR OPTIONS_ <br /> ROOF DECK FLUTE <br /> A341 105 FOR SPLAYED WIRE CONNECTION TO <br /> ,OSB • o COPE FLANGES OF STL ROOF DECK SEE 4 <br /> j ° ° • ° ° STUDS AND SECURE TO <br /> ° A131 <br /> I ° I CLG GRID W/(2)#8 SMS 1 <br /> H — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — H 1 12 GA(MIN)LATERAL SUPPORT WIRES <br /> 1 s� ANGLE NOT EXCEEDING 45°FROM THE <br /> ,7 SPLAYED 90°FROM EACH OTHER AT AN <br /> I i I � PLANE OF THE CEILING.ALL WIRES <br /> 11,571 <br /> �4, 1 ATTACHED TO MAIN RUNNER. <br /> W -- TFT_ TTff HIM1 (4)DIRECTIONS LATERAL BRAC-ING AT <br /> cn, 12'-0"OC IN EACHDIRECTION. FIRST BRACE <br /> 1 LOCATED WITHIN 6'-0"OF EACH WALL <br /> MAIN RUNNER @ 4'-0"O.C.ATTACH TO <br /> STRUT <br /> I (4)TURNS IN 1 1/2"TYP. <br /> 2"MAX <br /> TYP <br /> CONTRACTOR OPTION: <br /> NOTE: SUBMIT CERTIFIED CALCULATION AND <br /> METAL SUSPENSION SYSTEMS FOR ACOUSTICAL DETAILS FOR ALTERNATE COMPRESSION <br /> TILE AND LAY-IN PANEL CEILING SHALL BE INSTALLED POST TO ENGINEER AND ARCHITECT FOR <br /> i IN ACCORDANCE WITH ASCE 7 13.5.6,ASTM C636&E580 REVIEW AND APPROVAL <br /> I <br /> 2 ACT SEISMIC BRACING DETAIL <br /> A131 SCALE: NOT TO SCALE <br /> F - - - - - - - <br /> I <br /> 1771 HANGER WIRE <br /> 102 <br /> ACT GRID <br /> (E)ACT USG ACM7 SEISMIC USG ACM7 <br /> I _ _ EL= 14'-0"AFF SEISMIC CLIP <br /> CLIP ON TWO 8"TYP <br /> — ADJACENT SIDES' I ON TWO SIDES' <br /> MAX <br /> I I I <br /> WALL FINISH — PAINT COLUMNS BLACK <br /> TO TOP OF STARTING 1"ABOVE ACT <br /> I GYP BD CLG <br /> CEILING LINE TO 6" <br /> ABOVE ACT CEILING <br /> _pl <br /> LINE <br /> E ' DIMENSION TO ALIGN W/ PROFESSIONAL OF <br /> (E)GYP BULKHEAD I WALL MOULDING 7/8" 7/8" BOTTOM OF CEILING RECORD SEAL <br /> EL= 10'-0"AFF <br /> PAINT SALES FLOOR SIDE&BOTTOM, WALL MOULDING <br /> IPS-1,C-36 I EXTERIOR OR <br /> STARBUCKS SIDE, IPS-1,C-100 PERIMETER WALLS <br /> TFFR— <br /> S AR h <br /> (E)GYP BULKHEAD I — '_ ❑ COLUMN `G�,� C �T�� <br /> EL=9'-0"AFF <br /> PAINT ALL SIDES IPS-1,C-100 I _ — v ROBERT J.SARGENTI <br /> NOTE: POP RIVET ON SIDES W/0 SEISMIC CLIPS <br /> D - - - - - - - - - - - - - - - - - - - - - - - - - - - - No. C-31054 <br /> HIM III3 ACT SEISMIC PERIMETER DETAIL Rene 19 <br /> I <br /> 2 I A131 SCALE: 1 1/2"= 1'-0" Rene <br /> 9rF <br /> A302 I <br /> p` <br /> 12'DECO RING A133 <br /> PENDANT SEE <br /> ELECTRICAL <br /> ' I <br /> 8'DECO RING <br /> I PENDANT SEE SELF TAPPING SHT MTL <br /> 2 14 1/2"LONG MIN. <br /> ELECTRICAL-'— <br /> Al I <br /> ❑ _ _ SCREWS <br /> =� SEE DETAIL C ROOF DECK <br /> — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br /> RETROFIT EXISTING 124 <br /> DOWNLIGHTS FIXTURES, 123 <br /> SEE ELECTRICAL DWGS. <br /> PATCH AND REPAIR AS ° <br /> REQUIRED ° ��� <br /> ` — 2"X 2"X 12 GA ANGLE MIN <br /> o LO <br /> ° ° ° r <br /> °p HOLES 5/8"FROM EA END. <br /> ® I 1z7 <br /> SPLAY WIRE SUBSTITUTION, <br /> 7 111A 111 1zs SUCH AS I-LAG 750SD,MUST <br /> i 114 156 I I 12 GA SPLAYED WIRE <br /> A332 I m _ 151 ,s7 1ss 117 Iso 1s1 I � BRACING W/(4)TIGHT BE APPROVED BY DESIGN U <br /> 119 117A 126 <br /> I TURNS TO CEILING PROFESSIONAL OF RECORD <br /> I I 118 <br /> ftff_L <br /> 1s2 <br /> 107 — — 103 104A <br /> 120 I ,54 I 4 SEISMIC SPLAYED WIRE CONNECTION DETAIL U <br /> 100 ,00A 1006 104 110 108 <br /> A131 SCALE: NOT TO SCALE Q <br /> I 109 - <br /> 0 103ALL <br /> I <br /> 2 116 115 ® 1IF <br /> 71 163 164 <br /> A307 <br /> — — — — <br /> L Zr o 0 0 0 o 113 —� I <br /> q - - - - - - - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - - - - - � - - - - - - - - <br /> LI to o ''0 0 0 0 0 o ACT-1 LJ� <br /> — — — — — — — — — EL=8'-6"AFF W <br /> I I I I I I I I I I I <br /> 2 2 4 4 <br /> ui <br /> (E)GYP BULKHEAD A301 A303 A331 A332 J <br /> EL= 10'-0"AFF <br /> PAINT ALL SIDES IPS-1,C-36 (E)ACT <br /> I I I I I I I <br /> EL= 10'-01/2"AFF <br /> Z <br /> 1 2 3 4 5 6 7 8 9 10 11 O <br /> O <br /> 00 <br /> N <br /> 1 REFLECTED CEILING PLAN <br /> A131 SCALE: 1/16"= 1'-0" <br /> PROJECT NUMBER: T-0738 <br /> CONFIG: LL <br /> DRAWN BY: J.P. RIOS <br /> CHECKED BY: G.ABREU-GARCIA <br /> REFLECTED CEILING <br /> PLAN <br /> PLAN NORTH <br /> 1/17/2019 10:47:42 AM <br />