Laserfiche WebLink
WALL LEGEND: <br /> (E)WALLS TO REMAIN <br /> NEW WALLS <br /> F2 <br /> ILUMINATED MIRROR SCOPE OF WORK LEGEND: <br /> CENTER BETWEEN <br /> STALL(TYP), U.N.O <br /> 2 2 EXISTING NOT IN SCOPE <br /> CLOTHING HOOK 48" <br /> IN SCOPE OF WORK <br /> AFF MAX.TO BOTTOM F2 TARGET <br /> OF HOOK <br /> ILUMINATED MIRROR (E)ACT <br /> ACCESSIBLE I TYP. OF8EL=8'-6"AFF 1000 NICOLLET MALL <br /> NURSING STALL <br /> FLOOR PLAN NOTES MINNEAPOLIS, MN 55403 <br /> J - - - I- - - - - - I - - - - - - - - - - - J - - - I- - - - - - - - - - - - - A. SEE SHEET A001 FOR SYMBOLS <br /> I I I ® B. ALL DIMENSIONS ARE TO FINISH MATLS OR <br /> 105A ® OPENINGS UNO, EXCLUSIVE OF CERAMIC TILE <br /> C. FOR DOOR, ROOM FINISH,AND OWNER SUPPLIED MATL <br /> I i <br /> 015 -� I RESHOP • O O I 0 &EQUIP SCHEDULES, SEE SHEET A601 <br /> 0 <br /> F2 105A I D. PARTITION TYPES INDICATE LOCATION FOR BLOCKING, Z <br /> FITTING ROOM I I FINISHES, ETC. SEE SHEET A601 FOR PARTITION <br /> WEDGE MIRROR r'„ _ JL JL TYPES I <br /> TYP. OF 8 — — E. PLYWOOD BLKIN IS INCLUDED IN PARTITION TYPE, Ll <br /> EL=14'-0"AFF SEE BLOCKING PLAN FOR SIDE OF WALL <br /> 4 1 <br /> F2 05 FITTING F. FOR TYPICAL CONNECTION OF INTERIOR PARTITIONS TO <br /> BACKLIT MIRROR 7 A341 5 ROOM EXTERIOR WALLS-SEE 2 <br /> CENTERED BETWEEN 105 105 <br /> 9A501 TYP <br /> PARTITIONS I (E)AC O I <br /> rill <br /> s SST END CAP EL AFF <br /> SST CORNER GUARD G. FOR PARTIAL HEIGHT PARTITION BRACING AND FLOOR <br /> TO 4'-0"AFF J. .:,... ATTACHMENT DETAILS-SEE TO 4'-0"AFF �� I� — I � 12 13 <br /> 9 A341 1056 A502 A502 t n <br /> � O � <br /> V <br /> ACCESSIBLE 15 ' I FITTING I O O 0 • 0 (EI ACT 0 : : :.' H. ALL ANGLES ARE 45 DEGREE OR MULTIPLES OF 45 <br /> DEGREE, UNLESS NOTED OTHERWISE <br /> STALL ROOM 8 SST CORNER GUARD E =14'0" FF 461 FROM ROAD PARAMOS, NJ 07652 <br /> LOUNGE TO 7'-2"AFF <br /> J. FOR STUD WALLS EXTENDING TO(E)ROOF <br /> - - - - 1056 SST CORNER GUARDTI973.253.9393 WWW.SARGARCH.COM <br /> DECK <br /> TO 4'-0"AFF <br /> WHEELCHAIR EL_ <br /> (E)GYP SOFFIT , SEE <br /> 8 <br /> 10'0"AFF TYP <br /> CLEAR FLOOR — SST CORNER GUARD I 0. PAINT IPS-1, C-36 A501 <br /> " <br /> REVISIONS <br /> SPACE 30"X 48" TO 4'-0"AFF K. EXISTING FIRE EXTINGUISHERS ARE TO REMAIN IN THEIR DATE NO. DESCRIPTION <br /> 1 <br /> PAINT LIGHT FIXTURE CURRENT LOCATIONS. IF A FIRE EXTINGUISHER NEEDS <br /> TRIM IPS-6,C-100,TYP. <br /> TO BE RELOCATED DUE TO FIXTURE SHIFTS,THE FIRE 01117119 ISSUED FOR PERMIT <br /> EXTINGUISHER&SIGNS OR ASSOCIATED ITEMS ARE TO <br /> H - - - - - - - - - - - - - - �- --=1 - - - - - - - - - - - H - - - - - - - - - - - - - - - - - - BE RELOCATED AND INSTALLED NO FARTHER THAN 10'-0" <br /> SST CORNER GUARD FROM ITS CURRENT LOCATION. <br /> 20"X 48"X 18" TO 7'-2"AFF FINAL LOCATIONS PENDING FIRE MARSHAL <br /> AFF ACCESSIBLE I I WALK-THROUGH INSPECTION. <br /> BENCH CCTV PUBLIC VIEW <br /> MONITOR F-6"AFF TO FINISH PLAN GENERAL NOTES <br /> CENTERLINE OF JUNCTION BOX <br /> &SUPPORT RACKET, A. SEE SHEET A001 FOR SYMBOLS <br /> CENTER TO WALL <br /> B. FOR ADDITIONAL INFORMATION, SEE DOOR, ROOM <br /> FINISH,AND OWNER SUPPLIED MATL&EQUIP <br /> SCHEDULES-SHEET A601 <br /> C. ALL CPT, RF, RB,CT, QT, FTS, SSM,AND MT ARE FURNISHED <br /> BY OWNER AND INSTALLED BY GENERAL CONTRACTOR <br /> 2 FITTING ROOM REFLECTED CEILING PLAN <br /> 1 <br /> FITTING ROOM PLAN ALL K-PANEL, FRP&MARMOLEUM ARE FURNISHED BY <br /> OWNER AND INSTALLED BY GENERAL CONTRACTOR <br /> '341 SCALE: 1/4" = V-0" <br /> A341 SCALE: _ - <br /> D2 D3 D4 <br /> 2 D. CURVED FLOORING NODES TO BE PROCURED BY TARGET <br /> AND CUSTOM MANUFACTURED BY ARMSTRONG FLOORING. <br /> INSTALL CURVED FLOORING NODES PER SPECIFICATIONS <br /> AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> B/0 ACT CELING B/0 ACT CELING CONTACT DAVID ROPERTI WITH QUESTIONS AT <br /> EL=114'-0" EL=114'-0" DLROPERTI@ARMSTRONGFLOORING.COM <br /> F2 <br /> E. ALL SALES FLOOR COLUMNS RECEIVE STAINLESS STEEL <br /> FITTING ROOM F2 BASE. NO RESILIENT BASE AT COLUMNS, SEE 19 <br /> PARTITIONS <br /> I FITTING ROOM A502 <br /> IPS-1,C-100 Lm �PE� PARTITIONS <br /> if Lt I I F. INSTALL HYDRAULIC CEMENT BASED UNDERLAYMENT <br /> 5'6 3/4" a TO CREATE FEATHERED EDGE AT TRANSITION <br /> u i u u BETWEEN RESILIENT FLOORING AND EXPOSED <br /> IPS-1,C-36 <br /> u II IPS-1,C-100 CONCRETE FLOOR ON ALL SIDES. <br /> II SST CORNER <br /> IIII F2 <br /> GUARD TO 7'-2"AFF G. FLOOR FINISH CHANGES BETWEEN ROOMS OCCUR AT <br /> II II II II � II II <br /> F2 -BACKLIT MIRROR DOOR CENTERLINES TYPICAL.SEE A601 FOR ADDITIONAL <br /> I I <br /> ILUMINATED MIRROR CENTERED BETWEEN FLOOR FINISH INFORMATION. <br /> u II PARTITIONS <br /> F2 a ILUMINATED MIRROR u <br /> CENTER BETWEEN a H. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL <br /> STALL(TYP), U.N.O <br /> ILUMINATED MIRROR I K 201 CORNER GUARD-VERIFY REUSE OF EXISTING CORNER <br /> n II II II II II <br /> K-201 GUARD <br /> II II II I II o II II <br /> u RB-1A a RB-1A <br /> RB-1A ° a J. SST CORNER GUARDS AND WALL CAPS TO 4'-0"AFF UNLESS <br /> 7- L �7_-LEVEL 1 T/0 SLAB LEVEL 1 T/0 SLAB WALL PROTECTION IS TO 7'2"AFF IN WHICH CASE THE SST <br /> - - - - - - - - - - - - - - - - - - - EL=100'-0" EL=100'-0" CORNER GUARD OR WALL CAP WILL TERMINATE AT THE <br /> CZ) (E)DOOR TO <br /> SAME HEIGHT AS THE WALL PROTECTION. <br /> BE PAINT SST CORNER <br /> IPS-1,C-100 FULL HT IPS-6,C-36 GUARD TO T-0"AFF K. FOR SST CORNER GUARD/VERTICAL SST END CAPS TO <br /> CPT-201 INSTALLEDRB CONNECTION SEE <br /> RESHOP SST CORNER GUARD 11 <br /> OVER RF-16 o TO 4'0"AFF A502 <br /> 1'-0" 6'-0" v DIRECTION OF I 105A <br /> FTS 8A ALL SIDES RF-16 PATTERN RF-16,J L. INSTALL REDUCER STRIP(FTS-1A UNO)AT TRANSITION <br /> i a 5 FITTING ROOM ELEVATION BETWEEN RESILIENT FLOORING AND BROAD LOOM CARPET. <br /> o <br /> 0 4 FITTING ROOM ELEVATION A341 SCALE: 1/4" = 1'-0" El <br /> M. INSTALL REDUCER STRIP(FTS 2)AT TRANSITION BETWEEN <br /> < A341 SCALE: 1/4" = V-0" <br /> I o � AESSIIDES.FLOORING AND EXPOSED CONCRETE FLOOR ONFITTING PROFESSIONAL OF <br /> CL LLFTS-8A ROOM Y <br /> C? 105 ,/ FOR ADJACENT FINISHES, F2 N. DO NOT APPLY ANY SEALANT UNDER CT. RECORD SEAL <br /> � CPT 201 INSTALLED / SEE 2 FITTING ROOM F2 <br /> 26'-0" ��OVER RF-16 FTS 8A A701 2 PARTITIONS P. FOR K-PANEL WALL CAP, CORNER GUARD AND END <br /> FITTING ROOM <br /> CAP DETAILS SEE <br /> K-201 TO 4'-0"AFF PARTITIONS <br /> --- FTS-8A LL IPS 1, C-36 ABV L17 18 <br /> EL=114'0"` EL=114'-0­­rA502 A502 A502 A502 A502 �S Cl.I ¢ B/0 ACT CELING B/0 ACT CELING I FITTING AR <br /> ED C <br /> � ROOM <br /> _ <br /> RF-1 6—\ O a o LOUNGE IPS-1,C-36 IPS 1,C 100 v ROBERT J.SARGENTI <br /> 1056 <br /> co Y (E)HSS COLUMN 9-8 * No. C-31054 <br /> IPS-1,C-100 FULL HT <br /> 4'-0" IPS 6, C 36 07/31 <br /> CPT 201 INSTALLED FTS 1As� ` <br /> OVER RF-16 / 4'-2" a IPS-1,C-3614, 4 '9T Q� <br /> K-201 TO 4'-0"AFF INTERIOR ELEVATION NOTES <br /> FTS-8A IPS-1, C-36 ABV CPT-301 <br /> FOR ADJACENT FINISHES, � OPEN TO SALES II II F2 u I I A. CONTROL JOINTS SHOWN ARE SPECIAL <br /> SEE 3 \ u u <br /> - - - - - - - - - - - - - - - <br /> H A701 I ILUMINATED MIRROR II I CONDITIONS ONLY. REFER TO PROJECT MANUAL <br /> CENTER BETWEENa CRITERIA FOR LOCATION AND SPACING OF ALL <br /> STALL(TYP), U.N.O <br /> / u F2 OTHER CONTROL JOINTS <br /> \ II u I <br /> / u BACKLIT MIRROR B. FOR ADDITIONAL FINISH INFORMATION <br /> \ II a CENTERED BETWEEN SEE ROOM FINISH SCHEDULE-SHEET A601 <br /> u PARTITIONS <br /> u q RB 1A C. RB SHOWN AT ALL EXPOSED WALLS AND EXTENDS 6" <br /> RB 1A <br /> \ u BEHIND FIXTURES RB IS ALSO PLACED IN AREAS WITH <br /> `� it WC-6 AND AT JEWELRY BOAT FIXTURE <br /> LEVEL 1- LAB /T//0 SLEVEL 1-T/0 SLAB AL <br /> EL 1LAB EL 100'-0" D. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL <br /> SST ENDCAP CORNER GUARD-VERIFY REUSE OF EXISTING CORNER O <br /> TO 4'-0"AFF GUARD <br /> RB-1A E. ALL 7-1/4"OR GREATER WALL THICKNESSES TO HAVE(2) LO <br /> K-201 SEPARATE OUTSIDE STAINLESS CORNER GUARDS. IF <br /> SST CORNER GUARD WALL THICKNESS IS LESS THAN 7-1/4"USE(1) FULL WALL <br /> TO 4'-0"AFF THICKNESS STAINLESS STEEL END CAP <br /> PAINT TO EXTEND3 6"BEHIND FIXTUES. DO <br /> FITTING ROOM FINISH PLAN 6 FITTING ROOM ELEVATION 7 FITTING ROOM ELEVATION F SAND OR PAINT G PISUM BOARD CONSTRUCT ONOTHAT IS U <br /> A341 SCALE: 1/4" = V-0" A341 SCALE: 1/4" = V-0" <br /> A341 SCALE: 1/4" = 1'-0" CONCEALED BY FIXTURE <br /> G. VERIFY FINAL FIXTURE LOCATIONS W/OWNER r� <br /> H. FOR CONTROL JOINTS SEE 3 5 v <br /> A501 A501 TYP <br /> 2 H I. PROVIDE SLIP CONTROL JOINT AT ALL LOCATIONS U <br /> WHERE ROOF SUPPORTED BULKHEAD ABUTS FLOOR <br /> SUPPORTED 4 _ <br /> A501 Q <br /> B/0 ACT CELING OIL <br /> B/0 ACT CELING 09L <br /> WALL-SEE TYP <br /> EL=114'-0" EL=114'-0" <br /> J. ALL HM DOORS AND FRAMES ON SALES FLOOR TO BE <br /> IPS-1,C-36,6 (E)GYP SOFFIT I PAINTED TO MATCH ADJACENT WALL SURFACE LINO W <br /> EL= 10'-0"AFF <br /> PAINT IPS-1, C-36 \ WALL COVERING K. ANY EXPOSED WALL SURFACES GREATER THAN OR W <br /> WC-11 EQUAL TO 18"ADJACENT TO INTERIOR SALES FLOOR J <br /> I <br /> HARDLINES DOOR LOCATIONS TO RECEIVE KYDEX TO A <br /> IPS-1,C-36 I HEIGHT OF T-2". KYDEX COLOR SELECTION, K-11 OR <br /> OPEN CENTER LINE K-201,TO MATCH ADJACENT WALL SURFACE. <br /> / A 0/' OF�Ef� EL=108'-6" 7 <br /> 1 / L <br /> I <br /> 'OPEN TO SLAES / CCTV PUBLIC VIEW REFLECTED CEILING PLAN NOTES o <br /> MONITOR 8'-6"AFF TO <br /> CENTERLINE OF JUNCTION BOX A. SEE SHEET A001 FOR SYMBOLS. 00 <br /> I &SUPPORT RACKET, <br /> B. VERIFY LOCATIONS OF HANGING DEPARTMENT SIGNS <br /> CENTER TO WALL <br /> WITH TARGET'S IN STORE MARKETING. LOCATIONS <br /> / q <br /> K-201 / \ o K-201 SHOWN ARE FOR REFERENCE ONLY 6 <br /> RB-1A <br /> RB-1A A501 S1 <br /> LEVEL 1-T/0 SLAB 09L / �71 LEVEL 1-T/0 SLAB OIL <br /> EL-100'-0" EL-100'-0" C. ACT CEILING GRIDS ARE CENTERED IN ROOMS PER <br /> SPECIFICATION 09 5100 CRITERIA UNLESS NOTED <br /> OTHERWISE <br /> D. PROVIDE SLIP CONNECTION AT ALL WALLS EXTENDING PROJECT NUMBER: T-0738 <br /> TO ROOF OR STRUCTURE-SEE <br /> A501 <br /> 8 <br /> TYP CONFIG: LL <br /> FITTING ROOM LOUNGE ELEVATION 9 FITTING ROOM LOUNGE ELEVATION DOOR PAINT GENERAL NOTE E. EXITPROSIGNS <br /> REQUITITY NDLOCAIREMATION MARSHAL <br /> 8 EXIT SIGNS AS REQUIRED BY FIRE MARSHAL HAVING DRAWN BY: J.P. RIOS <br /> A341 SCALE: 1/4" = V-0" A341 SCALE: 1/4" = 1'-0" JURISDICTION <br /> F. REFER TO ELECTRICAL/MECHANICAL FOR LIGHT CHECKED BY: G.ABREU-GARCIA <br /> FIXTURE AND DIFFUSER RELOCATION. COORDINATE <br /> A. REFER TO ELEVATIONS AND OPENING SCHEDULE FOR HM FOR REMOVAL/REUSE OF LIGHTS, DIFFUSERS AND <br /> SPRINKLER HEADS <br /> DOOR AND FRAME FINISH INFORMATION. HM DOOR AND G. FOR ALIGNMENT OF SPRINKLER IN SALES FLOOR CEILING <br /> FRAME FINISHES ARE CALLED OUT IN THE OPENING SEE SPEC, DIV 21 <br /> SCHEDULE. FITTING ROOM <br /> B. HM DOORS AND FRAMES ARE NOT TO BE PAINTED C-100 PLANS & DETAILS <br /> WHITE, TYPICAL. <br /> CEILING LEGEND <br /> (E)ACT NEW ACT <br /> CEILING CEILING <br /> (E)GYP BD NEW GYP BD <br /> CEILING CEILING <br /> 1/15/2019 4:45:39 PM <br />