Laserfiche WebLink
OPENING SCHEDULE NOTES <br /> 1 PROVIDE VOID AND BLOCK-OUTS AS REQUIRED IN DOOR FRAME HEAD TO <br /> INSTALL CONDUIT,LOW VOLTAGE WIRE,AND REED SWITCHES LOCATED IN <br /> HEAD 6"FROM DOOR LATCH SIDE,EACH DOOR LEAF. COORDINATE THIS <br /> WORK WITH THE ELECTRICAL CONTRACTOR AND SECURITY CONTRACTOR <br /> TO PROVIDE FREE ACCESS FROM OVERHEAD,THROUGH FRAME WHERE <br /> NEW OPENING SCHEDULE 2 PROVIDE VOID AND BLOCK-OUTS AS REQUIRED IN DOOR FRAME JAMB TO <br /> DOOR/ LEFT DOOR RIGHT DOOR FIRE HARDWARE FRAME FRAME INSTALL ELECTRIC STRIKE AND WIRING VERIFY AND COORDINATE WITH <br /> DOOR TYP ES OPENING ROOM NAME D/W TYPE PANEL MATERIAL QTY D/W WIDTH WIDTH WIDTH D/W HEIGHT THICKNESS GL TYPE RATING GROUP TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL NOTES HARDWARE SUPPLIER AND ELECTRICAL CONTRACTOR. <br /> 3 SEE INTERIOR PAINTING NOTES AND FINISH MATERIAL AND COLOR CODE", <br /> SHEET A601 FOR INTERIOR DOOR AND FRAME COLORS. <br /> VISION 102.3 SALES TD1 INSUL 2 6-0" T-0" 3'-0" 8'-0" 13/4" GL-5 - 91.0 1 STL 8/A611 8/A611 - 3,5,7,16 4 1"UNDERCUT <br /> PANEL 104 CASH OFFICE F HM 1 3'-0" T-0" T-0" 13/4" - 69.0 1 HM 1/A611 2/A611 - 4, 19 5 FRAMES AT TRAFFIC DOORS TO BE PAINTED IPS-6,SEE ELEVATIONS FOR <br /> 104A CASH OFFICE VESTIBULE F HM 1 T-0" T-0" 7'-0" 13/4" - 68.1 1 HM 1/A611 2/A611 - 4, 19 COLOR. TARGET® <br /> 6 SIZE INDICATED IS FOR ROUGH OPENING SIZE DOOR ACCORDINGLY. <br /> 7 TRAFFIC DOORS FURNISHED BY OWNER. <br /> 8 FRAME ONLY,NO STOPS. FIELD MEASURE TO MATCH EXISTING OPENING. 1000 N ICOLLET MALL <br /> 9 EXISTING FRAME TO REMAIN. FIELD MEASURE TO MATCH EXISTING FRAME <br /> OPENING TO VERIFY SIZE OF NEW DOOR. MINNEAPOLIS, MN 55403 <br /> 10 CONTRACTOR TO VERIFY IF THERE IS EXISTING PANIC HARDWARE ON PUSH <br /> M EXISTING OPENING SCHEDULE EXISTING OPENING SCHEDULE EXISTING OPENING SCHEDULE SIDE OF DOOR. IF NO PANIC HARDWARE,GC TO CONTACT ARCHITECTURAL <br /> PROJECT REPRESENTATIVE FOR REQUIRED HARDWARE REPLACEMENT. <br /> DOOR/ FIRE HARDWARE DOOR/ FIRE HARDWARE DOOR/ FIRE HARDWARE 11 PAINT HM DOOR AND FRAME IPS-6,C-9. <br /> F-FLUSH TRAFFIC DOOR OPENING ROOM NAME RATING GROUP NOTES OPENING ROOM NAME RATING GROUP NOTES OPENING ROOM NAME RATING GROUP NOTES 12 PAINT HM DOOR AND FRAME IPS-6,C-36. <br /> TD-1 (RED) 13 PAINT HM DOOR AND FRAME IPS-6,C-51. <br /> G714 PAINT OFFICE SIDE OF HM DOOR AND FRAME ONLY <br /> 100.1 VESTIBULE 117.1 CIRCULATION 12,20 141.1 CIRCULATION 15 PAINT TD FRAME IPS-6,C-36. <br /> 100.2 VESTIBULE - 117.2 CIRCULATION 12,20 141.2 CIRCULATION - - 16 PAINT TD FRAME IPS-6,C-9. <br /> 100A.1 VESTIBULE - - 119 JANITOR 15,21 141.3 CIRCULATION - - 17 PAINT HM FRAME ONLY IPS-6,C-36 <br /> 100A.2 VESTIBULE - - - 120 FOOD SERV STORAGE - 141.4 CIRCULATION - - - 18 PAINT INTERIOR SIDE OF DOOR AND FRAME ONLY. I <br /> 10013.1 VESTIBULE - - - 120.1 FOOD SERV STORAGE 15,21 142 FIXTURE STORAGE - - - 19 SEE EXTERIOR ELEVATIONS A201. FOR EXTERIOR SIDE <br /> Li <br /> FRAME TYPES 1006 20 PAINT OCD DOOR AND FRAME EFS-21,C-43..2 VESTIBULE - - - 125 STORAGE 13,21 143 RESTROOM - - - 21 PAINT SALES SIDE OF HM DOOR AND FRAME ONLY. <br /> 102 SALES - - 12 126 PHARMACY 12, 14 146 ELECTRONIC STOCK - - - <br /> 102.2 SALES - - 12,20 126.1 PHARMACY - 154 ELECTRICAL - - 13,14 <br /> 102.4 SALES - - 12,21 127 PHARMACY RESTROOM 12, 14 156 ETL/HR - 64.1 13 <br /> 102.5 SALES - - 3,5,15 130 COMPACTOR/BALER - 157 LOUNGE - 73.0 13 ' L <br /> 102.6 SALES - - 12,20 131 RECEIVING 157.1 LOUNGE - - - <br /> 105 FITTING ROOM STORAGE - - 12 131.1 RECEIVING 158 TRAINING - 59.0 13 <br /> RAGE <br /> 2"TYP <br /> 108.1 CIRCULATION - - 1920 131.3 MARKINIGG 1610 STLOOFFICE - 64.1 1314 HARDWARE GROUP KEY <br /> 108.2 CIRCULATION - - 19 131.5 MARKING 162 OPEN OFFICE - - 19 <br /> 110 TSC STORAGE - 63.3 13 134 WATER SERVICE 163 CONFERENCE - 64.1 13 <br /> INTERIOR&EXTERIOR DOORS: 461 FROM ROAD, PARAMUS, NJ 07652 <br /> 111 AP OFFICE - 68.6 13 138 ELECTRICAL 164 STORAGE - - 13,14 GROUPS 16-30 -EXTERIOR HOLLOW METAL DOORS-SINGLE <br /> TYPE 1 TYPE 4 111.1 CCTV - - 13 138.1 ELECT.SERVICE ROOM 180 DAIRY COOLER - - - T 19 7 3.2 5 3.9 3 9 3 WWW.S A R G A R C H.C O M <br /> GROUPS 31-45 -EXTERIOR HOLLOW METAL DOORS-PAIR <br /> STEEL 114 CONTROL ROOM - - 14 139 NIGHT MAINT 181 FREEZER - - - GROUPS 46-55 -EXTERIOR SPECIAL DOORS <br /> CHANNEL 115 WOMEN - - 15,21 140 DAY MAINTENANCE 182 MEAT COOLER - - - GROUPS 56-75 -INTERIOR HOLLOW METAL DOORS-SINGLE REVISIONS <br /> OR ANGLE 116 MEN - - 15,21 141 CIRCULATION 183 PRODUCE COOLER - - - GROUPS 76-90 -INTERIOR HOLLOW METAL DOORS-PAIR <br /> 185 VACUUM PUMP ROOM - - GROUPS 91-99 -INTERIOR SPECIAL DOORS DATE N0. DESCRIPTION <br /> 01/17/19 ISSUED FOR PERMIT <br /> SUFFIXES: (EXAMPLE-GROUP 20-A) <br /> A -ADD ARMOR PLATE EDGE PROTECTOR AND TRIM <br /> PROTECTOR BAR IN LIEU OF KICKPLATE <br /> C -ADD"HOLDER" FUNCTION TO CLOSER-4041 H <br /> T -ADD TRIM PROTECTOR BAR <br /> V -ADD OVERHEAD STOP(GJ-90) IN LIEU OF SPECIFIED STOP <br /> GENERALNOTES <br /> 1 ALUMINUM FRAMING SYSTEM , HM FRAMES, HM DOORS,AND <br /> HARDWARE GC FURNISHED <br /> GLAZING KEY- <br /> SPEC SECTION 08 4100&08 8800 <br /> GLAZING- <br /> GL-2 1/4"THICK CLEAR TEMPERED GLASS <br /> GL-3 1/2"THICK CLEAR TEMPERED GLASS <br /> GL-4 1/4"THICK CLEAR TEMPERED GLASS-PLATED REFLECTIVE <br /> GL-5 EXTRUDED POLYCARBONATE <br /> GL-7 1/4"THICK CLEAR FILM FACED WIRED GLASS <br /> GL-13 9/16"THICK RED LAMINATE GLASS <br /> GL-14 9/16"THICK WHITE LAMINATE GLASS <br /> GL-15 3/4"THICK CLEAR TEMPERED GLASS <br /> NOTE:SEE PROJECT MANUAL FOR GLAZING <br /> TYPES INCLUDED IN PROJECT <br /> VISION PANEL CLEAR SIZES <br /> TYPE V=10"X 10" <br /> SEE PLAN FOR TYPE N=6"X 34" <br /> 362S125-30 PARTITION TYPE TYPE G=22"X 34" <br /> MET STUD <br /> SEE PLAN <br /> FOR PARTITION TYPE 20 GA MET STUDS JAMB 1/8" PAINTING NOTES <br /> ANCHORS <br /> VARIES EXTERIOR: <br /> 1/2" N A HOLLOW METAL DOORS AND FRAMES. ALL FACES OF DOOR, EXCEPT <br /> L J + + C 8 X 11.5 JAMB-ANCHOR TO INTERIOR FACE, EFS 17. INTERIOR FACE OF DOOR IPS 6. EXTERIOR SIDE OF <br /> AT IM CONDITION VARIES <br /> t� S CO 0 _ <br /> RUNNER TRACK 1/2.. SLAB W/L 4X3X1/4X 0 6 LLV FRAME TO STOP, EFS-17. INTERIOR SIDE OF FRAME, INCLUDING ENTIRE <br /> NO STOP IN HM FRAME W/TWO 1/2"DIA X 3"EXP BOLTS STOP, IPS-6. COLOR CHANGE OCCURS AT PAINT SYSTEM CHANGE LINE. <br /> AT SIM CONDITION <br /> o U' � B ITEMS ON BUILDING WALLS: ELEC CONDUIT, PIPING, PTZ CAMERA <br /> NO STOP IN HM FRAME - HOUSING AND MOUNTING BRACKETS AND OTHER MISC METAL ITEMS: <br /> `N } EFS-20/COLOR TO MATCH ADJACENT SURFACE. <br /> C ITEMS ON ROOF: ROOFTOP MECHANICAL EQUIPMENT IS FACTORY <br /> VARIES FINISHED OR UNPAINTED ALUMINUM PER SPECIFICATION. OSR TO <br /> DETERMINE WHICH EQUIPMENT IS VISIBLE AND REQUIRES PAINTING. <br /> INTERIOR: <br /> A HM DOORS AND FRAMES TO BE PAINTED IPS-6,C-36(RIVER REFLECTIONS) <br /> TRAFFIC DOOR UNLESS NOTED OTHERWISE. <br /> B HM DOORS AND FRAMES IN THE OFFICE AREA TO BE PAINTED IPS-6, C-51 <br /> (BACKDROP), UNLESS NOTES OTHERWISE. <br /> C HM&STEEL FRAMES AT TRAFFIC DOORS TO BE PAINTED C-36, UNLESS <br /> NOTED OTHERWISE. <br /> D HM DOOR FRAMES FOR WOOD DOORS TO BE PAINTED IPS-6,C-36 UNO. <br /> 1 HEAD HM / GYP BD 2 JAMB HM/GYP BD 3 JAMB HM TIGHT TO WALL 8 TRAFFIC DOOR JAMB HEAD SIM E DOORS: PAINT TOP, BOTTOM,ALL EDGES AND GLAZING STOPS TO MATCH <br /> FACE of DOOR. PROFESSIONAL OF <br /> A611 SCALE: 1 1/2"= V-0" A611 SCALE: 1 1/2" = V-0" "- '- "- '- " <br /> A611 SCALE: - A611 SCALE: - RECORD SEAL <br /> SED A R Cy/T <br /> ROBERT J.SARGENTI <br /> * No. C-31054 <br /> 07/31/1 <br /> Sj, Re <br /> C 'co <br /> (E)JOIST NOTE: <br /> PA EDIT NOTE: ANGLES TO BEAR AGAINST CHANNEL. DO NOT <br /> WHEN TRAFFIC DOOR IS NOT LOCATED UNDER (E)ROOF DECK WELD ANGLES TO CHANNEL-VERTICAL SLIP <br /> BEAM,JOIST,OR JOIST GIRDER, REVISE THE SLIP CONNECTION. <br /> CONNECTION NOTE WITH THE FOLLOWING NOTE: <br /> C6X8.2-FOR <br /> SLIP <br /> CONNECTION SEE <br /> @)@) <br /> (E)JOIST <br /> O <br /> co <br /> BEAR ANGLES <br /> LO <br /> C6 X 8.2-ATTACH TO BOTTOM OF CHANNEL. <br /> JOIST GIRDER W/L 4X3X1/4X 0'4° DO NOT WELD El <br /> LLV PROVIDE SLOTTED HOLE ON TO CHANNEL. <br /> VERT LEG OF L @ ROOF FRAMING - -Il LI <br /> TO ALLOW FOR 1 1/2"DEFLECTION. C6 <br /> HSS AT SIM v <br /> AT DOOR 102.1 ATTACH TO WALL L6 X 3 X 1/4 LLV .. <br /> PANEL EA SIDE OF <br /> LAP C6 V-0"MIN ONTO C8 r <br /> CENTER C6 ON C8 DEPTH. CHANNEL 1/8� <TYP <br /> FIELD WELD C6 TO C8 11 LI <br /> C8X11.5FRAME r <br /> L6X3 <br /> GRIND WELDS SMOOTH -<TYP (E)JOIST BOTTOM <br /> BETWEEN HEAD&JAMBS 1/8 L3X3 <br /> 8 @ SIM-JAMB DET 10/A611 6„ CHORD(WEBS NOT <br /> A611 DOES NOT APPLY TYP SHOWN) <br /> L3X3X1/4X0'-10"EASIDE - 11 <br /> OF CHANNEL. BEAR AGAINST A611 <br /> CHANNEL. DO NOT WELD W <br /> TO CHANNEL VERTICALC6(ORIENTATION MAY VARY) <br /> SLIP CONNECTION HSS AT SIM LV <br /> 9 TRAFFIC DOOR FRAME 10 TRAFFIC DOOR FRAME BRACING 11 TRAFFIC DOOR FRAME BRACING J <br /> A611 SCALE: 1/4" = V-0" A611 SCALE: 1 1/2" = V-0" <br /> A611 SCALE: 1 1/2" = 1'-0" <br /> Z <br /> 00 <br /> N <br /> PROJECT NUMBER: T-0738 <br /> CONFIG: LL <br /> DRAWN BY: J.P. RIOS <br /> CHECKED BY: G.ABREU-GARCIA <br /> OPENING <br /> SCHEDULE & <br /> DETAILS <br /> A 11 <br /> 1/17/2019 5:49:31 PM <br />