Laserfiche WebLink
WALL LEGEND <br /> I— (E)WALLS TO REMAIN <br /> 11 10 9 8 7 6 <br /> NEW WALLS <br /> I I I I I <br /> I I I I I <br /> FLOOR PLAN NOTES <br /> A. SEE SHEET A001 FOR SYMBOLS <br /> I I I I I <br /> B. ALL DIMENSIONS ARE TO FINISH MATLS OR <br /> OPENINGS LINO, EXCLUSIVE OF CERAMIC TILE <br /> i C. FOR DOOR, ROOM FINISH,AND OWNER SUPPLIED MATL <br /> TARGET® <br /> &EQUIP SCHEDULES,SEE SHEET A601 <br /> I I I I I <br /> I D. PARTITION TYPES INDICATE LOCATION FOR BLOCKING, 1000 NICOLLET MALL <br /> MINNEAPOLIS, MN 55403 <br /> FINISHES, ETC. SEE SHEET A601 FOR PARTITION <br /> TYPES <br /> E. PLYWOOD BLOCKING IS INCLUDED IN PARTITION TYPE, <br /> SEE BLOCKING PLAN FOR SIDE OF WALL <br /> I F. FOR TYPICAL CONNECTION OF INTERIOR PARTITIONS TO <br /> a EXTERIOR WALLS-SEE <br /> UV U I 2 <br /> — — ooEd A501 TYP <br /> - I s <br /> I o G. FOR PARTIAL HEIGHT PARTITION BRACING AND FLOOR <br /> IPS-1, C-100 I /� sNacKs sopa ATTACHMENT DETAILS-SEE I <br /> FULL HT — � � 0 12 13 <br /> I M 31 A502 A502 <br /> EMPLOYE L <br /> HIGH T 1 V <br /> H. ALL ANGLES ARE 45 DEGREE OR MULTIPLES OF 45 <br /> T DEGREE, UNLESS NOTED OTHERWISE <br /> xx xx v xx v x v xx S L R S L R <br /> v J. FOR STUD WALLS EXTENDING TO(E)ROOF rt <br /> eE I <br /> � DECK,SEE 8 <br /> _ s _ s _ TYP <br /> Ir' <br /> I I N K. EXISTING FIRE EXTINGUISHERS ARE TO REMAIN IN THEIR <br /> _ CURRENT LOCATIONS. IF A FIRE EXTINGUISHER NEEDS <br /> es r r TO BE RELOCATED DUE TO FIXTURE SHIFTS,THE FIRE • <br /> EXTINGUISHER&SIGNS OR ASSOCIATED ITEMS ARE TO <br /> f xx xx xx v xx v xx of M <br /> _ _ _ - -- _ _ _ _ _ _ _ _ _ _ BE RELOCATED AND INSTALLED NO FARTHER THAN 10'-0" 461 FROM ROAD, PARAMUS, NJ 07652 <br /> H� FROM ITS CURRENT LOCATION. <br /> FINAL LOCATIONS PENDING FI RE MARSHAL TI973.253.9393 WWW.SARGARCH.COM <br /> 1 lnv3Ei WALK-THROUGH INSPECTION. <br /> ,o I K-201 TO 4'-0"AFF •�• I ��/��� I /��� REVISIONS <br /> IPS-1,C-100 ABV DATE N0. DESCRIPTION <br /> FINISH PLAN GENERAL NOTES 01/17/19 ISSUED FOR PERMIT <br /> FVII I , A. SEE SHEET A001 FOR SYMBOLS I I I I I I I I I �FVF. L+i� F- <br /> I <br /> I <br /> B. FOR ADDITIONAL INFORMATION,SEE DOOR, ROOM <br /> I FINISH,AND OWNER SUPPLIED MATL&EQUIP <br /> SCHEDULES-SHEET A601 <br /> 6 C. ALL CPT, RF, RB, CT,QT, FTS, SSM,AND MT ARE FURNISHED <br /> BY OWNER AND INSTALLED BY GENERAL CONTRACTOR <br /> ALL K-PANEL, FRP&MARMOLEUM ARE FURNISHED BY <br /> OWNER AND INSTALLED BY GENERAL CONTRACTOR <br /> 1 FRONT SALES FLOOR FINISH PLAN D2 D3 D4 <br /> A702 SCALE: 1/8" = 1'-0" <br /> D. CURVED FLOORING NODES TO BE PROCURED BY TARGET <br /> AND CUSTOM MANUFACTURED BY ARMSTRONG FLOORING. <br /> INSTALL CURVED FLOORING NODES PER SPECIFICATIONS <br /> 10 LIGHT VALANCE 9 8 7 6 AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> TYP,COORDINATE WITH <br /> CONTACT DAVID ROPERTI WITH QUESTIONS AT <br /> ELECTRICAL SEE:; 5 DLROPERTI@ARMSTRONGFLOORING.COM <br /> IPS-1,C-36 A701 IPS 1,C-204 PHARMACY NO WORK IPS-1,C-36 E. ALL SALES FLOOR COLUMNS RECEIVE STAINLESS STEEL <br /> 8 PAINT BULKHEADS IPS 1,C 100 BASE. NO RESILIENT BASE AT COLUMNS, SEE <br /> I <br /> 28'-0 1/2" A701 i I i i BEAUTY SCREENS 1 g <br /> DASHED FOR REFERENCE, A502 <br /> SIM (E)SIGN TO REMAIN (E)PAINT DOOR&FRAME PROVIDED BY OTHERS <br /> 7 K-201 IPS-6,C-36 F. INSTALL HYDRAULIC CEMENT BASED UNDERLAYMENT <br /> 701 TO CREATE FEATHERED EDGE AT TRANSITION <br /> jllll B/0 ACT if I BETWEEN RESILIENT FLOORING AND EXPOSED <br /> EL=114'-0" I <br /> F I �[pharmacyF CONCRETE FLOOR ON ALL SIDES. <br /> I <br /> G. FLOOR FINISH CHANGES BETWEEN ROOMS OCCUR AT <br /> J DOOR CENTERLINES TYPICAL.SEE A601 FOR ADDITIONAL <br /> FLOOR FINISH INFORMATION. <br /> OPEN <br /> 7 / / \ H. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL <br /> NO PAINT N NO PAINT CORNER GUARD-VERIFY REUSE OF EXISTING CORNER <br /> NO PAINT GUARD <br /> LEVEL 1 -T/0 SLAB J. SST CORNER GUARDS AND WALL CAPS TO 4'0"AFF UNLESS <br /> EL=100'-0" WALL PROTECTION IS TO 7'-2"AFF IN WHICH CASE THE SST <br /> — — — — — — — — K-201 SSTTO 7E2"AFF ND CAP I CONTINUE PAINT 6"MIN. BEHIND <br /> 7 <br /> HARDLINES FIXTURES SST CORNER (E)PAINT DOOR&FRAME HARDLINE FIXTURES,TYP. CORNER GUARD OR WALL CAP WILL TERMINATE AT THE <br /> SAME HEIGHT AS THE WALL PROTECTION. <br /> DASHED FOR REFERENCE,TYP. GUARD RB-1A RB-1A RB-1A IPS-6,C-36 RB-1A <br /> SIGNAGE BY OWNER, TO 7'-2"AFF K. FOR SST CORNER GUARD/VERTICAL SST END CAPS TO <br /> SHOW OUTLINE FOR K-201 SST END CAP RB CONNECTION SEE <br /> REF. ONLY CONTINUE RUBBER BASE 6"MIN. 11 <br /> TO 7'-2"AFF BEHIND HARDLINE FIXTURES,TYP. A502 <br /> PAINT DOOR&FRAME <br /> BEYOND, IPS-6,C-36 L. INSTALL REDUCER STRIP(FTS-1A UNO)AT TRANSITION <br /> 2 FRONT INTERIOR SALES FLOOR ELEVATION BETWEEN RESILIENT FLOORING AND BROAD LOOM CARPET. <br /> A702 SCALE: 1/8" = V-0" M. INSTALL REDUCER STRIP(FTS-2)AT TRANSITION BETWEEN <br /> RESILIENT FLOORING AND EXPOSED CONCRETE FLOOR ON <br /> ALL SIDES. <br /> N. DO NOT APPLY ANY SEALANT UNDER CT. <br /> P. FOR K-PANEL WALL CAP,CORNER GUARD AND END <br /> 5 4 3 2 1 CAP DETAILS SEE <br /> 10 11 12 17 18 <br /> A502 A502 A502 A502 A502 PROFESSIONAL OF <br /> RECORD SEAL <br /> I I I I <br /> q - - - - - - - - - - - - - - - - - - - - - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - <br /> SEo A R cy/�' <br /> 'A <br /> - V V ROBERT J.SARGENTI <br /> — OFW32 No. C-31054 <br /> CASH <br /> o WF2395 07/3 <br /> - - ,-- U U U I- 9 F97F7 0 <br /> � SAFE GEe� I <br /> ewe• OF01]9 <br /> I I I L - r I <br /> K-201 TO T-2"AFF, <br /> I — o o I IPS-1, C-36 ABOVE <br /> W3 57 <br /> g _ 17 <br /> L I ��I O ❑ O <br /> I <br /> 1 > — I <br /> � 0 0 a — J — <br /> o ® <br /> K-20 LO <br /> 1 TO T-2"AFF, I � � I ®I <br /> IPS-1,C-36 ABOVEG) <br /> cn cn � � cn cn I <br /> — ' — — — — — — — — — —— — — — — — — — — — — — — <br /> I I I Fil 1-1 1-1I I ° Ej <br /> ti ti <br /> T, T �� ■ III I l — <br /> 17TTFF-111 �Trr_li 7T F-1 IrTr'I �Tr'I <br /> Q <br /> U � <br /> 3 FRONT SALES FLOOR FINISH PLAN p <br /> A702 SCALE: 1/8" = V-0" <br /> W <br /> W <br /> r� <br /> V <br /> Z <br /> C) <br /> 00 <br /> N <br /> 5 4 3 2 <br /> IPS-1,C-36 <br /> I I I I <br /> BEAUTY SCREENS SST CORNER GUARD (E)PAINT DOOR&FRAME A 03 7 SST END CAP <br /> DASHED FOR REFERENCE, PROVIDED BY OTHERS TO 7'-2"AFF A701 TO 7'-2"AFF <br /> IPS-6,C-36 <br /> I I PROJECT NUMBER: <br /> T-0738 <br /> I <br /> CONFIG: LL <br /> — I--� <br /> — — — — — — — — — — I OO torr makup <br /> 7-1'001/ I G3@&vy I I A302 <br /> NO PAINT N I �, I CHECKED BY: G.ABREU-GARCIA <br /> LEVEL 1 -T/0 SLA VE 1 -T/0 SLA <br /> EL=100'-0" - - - - - - - - -I- - - EL=100'-0" <br /> i i i - i - - - - - - - ENLARGED FINISH <br /> K-201 RB-1A (E)ENTRY&STOREFRONT STARBUCKS 1B-1A <br /> TO REMAIN SEE A301 NO SCOPE K-201 PLANS & <br /> ELEVATIONS <br /> 4 FRONT INTERIOR SALES FLOOR ELEVATION <br /> A702 SCALE: 1/8" = V-0" A7 2 <br /> 1/17/2019 4:13:20 PM <br />