SHEET SHEET NAME
<br /> 00-GENERAL
<br /> G001 COVER SHEET
<br /> G002 SITE PLAN(REFERENCE ONLY)
<br /> G003 ACCESSIBILITY DETAILS
<br /> G004 CAL GREEN
<br /> San Joaquin County G005 CAL GREEN
<br /> Environmental Health Department
<br /> 1868 E. Hazelton Ave. 30_ARCHITECTURAL DEMOLITION
<br /> Stockton, CA 95205
<br /> AD111 DEMOLITION FLOOR PLAN
<br /> • ` (209) 468-3420
<br /> fioi'
<br /> 40-ARCHITECTURAL
<br /> APPROVED WITH CONDITIONS A001 GENERAL ARCHITECTURAL INFORMATION
<br /> A021 CODE COMPLIANCE PLAN
<br /> For conditions, please see approval letter dated: 5-3-21 A214 EIFS SECTIONS&DETAILS TARGET®
<br /> A111 FLOOR PLAN
<br /> Approved by: ICaG�G�a!?�IG� Ll!?Glai'et Date: May 03, 2021 Al 21 FLOOR FINISH&WALL FINISH PLAN
<br /> Al 25 INSULATION AND BLOCKING PLAN 1000 N(COLLET MALL
<br /> Al 31 REFLECTED CEILING PLAN MINNEAPOLIS, MN 55403
<br /> Al 33 ENLARGED REFLECTED CEILING PLANS&DETAILS
<br /> A201 EXTERIOR ELEVATIONS
<br /> A212 ENLARGED EXTERIOR ELEVATION&WALL SECTIONS
<br /> A301 ENTRY PLANS, ELEVATIONS&DETAILS
<br /> A302 ENTRY MALL PLANS, ELEVATIONS
<br /> A303 GUEST SERVICES PLANS&ELEVATIONS
<br /> A304 GUEST SERVICE DETAILS
<br /> A307 RESTROOM PLAN, ELEVATIONS&DETAILS
<br /> A331 OFFICE PLANS I
<br /> A332 OFFICE PLANS Li
<br /> A335 OFFICE DETAILS
<br /> A341 FITTING ROOM PLANS&DETAILS r
<br /> A501 INTERIOR DETAILS v
<br /> A502 INTERIOR DETAILS A'
<br /> A601 PARTITION TYPES&SCHEDULES r
<br /> A611 OPENING SCHEDULE&DETAILS
<br /> A701 SALES FLOOR ELEVATIONS&DECOR DETAILS
<br /> A702 ENLARGED FINISH PLANS&ELEVATIONS r /�
<br /> 60 STRUCTURAL v '
<br /> S141 GENERAL STRUCTURAL NOTES,PARTIAL ROOF FRAMING PLANS&DETAILS
<br /> 461 FROM ROAD, PARAMUS, NJ 07652
<br /> 62_STRUCTURALFIXTURE TI973.253.9393 ■ WWW.SARGARCH.COM
<br /> SR11 STRUCTURAL FIXTURE PLAN
<br /> SR51 PALLET RACK ANCHORAGE&DETAILS
<br /> SR52 LIGHT DUTY SHELVING ANCHORAGE&DETAILS REVISIONS
<br /> SR53 SALES FLOOR GONDOLA ANCHORAGE&DETAILS DATE NO. DESCRIPTION
<br /> 01117119 ISSUED FOR PERMIT
<br /> 70 PLUMBING
<br /> PM01 MECHANICAL SHEET INDEX
<br /> PC01 TITLE 24 CODE COMPLIANCE
<br /> P111 OVERALL PLUMBING PLAN
<br /> P301 JANITOR,NIGHT MAINTENANCE,&LOUNGE PLUMBING PLANS
<br /> P411 MARKET PLUMBING PLANS
<br /> P431 CONDENSATE VACUUM DETAILS
<br /> P601 PLUMBING SCHEDULES&DETAILS
<br /> 71 MECHANICAL
<br /> M111 OVERALL HVAC PLAN
<br /> M301 OFFICES&GUEST SERVICE HVAC PLANS
<br /> M321 FITTING ROOMS HVAC PLANS
<br /> 2019 RErAIDDEL M601 MECHANICAL SCHEDULES&DETAILS
<br /> 72 FIRE PROTECTION
<br /> F111 FIRE PROTECTION PLAN
<br /> 73-REFRIGERATION
<br /> RD01 REFRIGERATION DEMOLITION PLANS
<br /> R111 REFRIGERATION SYSTEM PLAN
<br /> R401 MARKET AREA CASE SETTING&PIPING PLANS
<br /> R511 REFRIGERATION DETAILS
<br /> R601 REFRIGERATION SCHEDULES
<br /> R602 REFRIGERATION SCHEDULES
<br /> R621 REFRIGERATION CONTROLS PLANS
<br /> 80-ELECTRICAL
<br /> E001 ELECTRICAL COVER SHEET
<br /> E002 LIGHTING ENERGY COMPLIANCE
<br /> VICINITY MAP: LOCATION MAP: BUILDING CODE SUMMARY: REMODEL SCOPE OF WORK: E004 LIGHTING ENERGY COMPLIANCE
<br /> E005 LIGHTING ENERGY COMPLIANCE
<br /> MIXED OCCUPANCIES E003 LIGHTING ENERGY COMPLIANCE
<br /> E623 PANELBOARD SCHEDULES
<br /> THIS BUILDING IS DESIGNED PER IBC SECTION 508.2 ACCESSORY OCCUPANCY,CBC SECTION 508.1 FOR MIXED OCCUPANCIES AND ED111 LIGHTING DEMOLITION PLAN
<br /> CBC SECTION 508.3 FOR NON-SEPARATED USE. ED211 POWER&SYSTEMS DEMOLITION PLAN
<br /> E111 LIGHTING PLAN
<br /> PER CBC SECTION 508.2.4(ACCESSORY USES), NO FIRE SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES(A-2&B) E121 SPECIALTY LIGHTING PLAN
<br /> • y ;r •- ,` _ AND THE MAIN OCCUPANCIES(M&S-1). NO ASBESTOS AND NO ASBESTOS-BEARING MATERIALS ARE ALLOWED E124 A&A TRACK LIGHTING PLAN
<br /> '* - ON THIS PROJECT
<br /> "
<br /> ..
<br /> PER CBC SECTION 508.3 NONSEPARATED OCCUPANCIES BUILDINGS OR PORTIONS OF BUILDINGS THAT COMPLY WITH THE E131 ENTRY LIGHTING PLAN
<br /> PROVISIONS OF THIS SECTION SHALL BE CONSIDERED AS NONSEPARATED OCCUPANCIES. E141 OFFICE LIGHTING PLANS
<br /> " `•'` A. ARCHITECTURAL WORK IS LIMITED TO MINOR DEMOLITION AND REPAIR/REPLACEMENT OF
<br /> ' PER CBC SECTION 508.3.3 NO SEPARATION IS REQUIRED BETWEEN NON SEPARATED OCCUPANCIES E151 GROCERY,ADULT BEVERAGE&HOME TRACK LIGHTING PLANS
<br /> FINISHES.THE EXISTING OCCUPANCY, USE, LIFE SAFETY AND EGRESS ARE NOT IMPACTED BY
<br /> 4E161 OCCUPANCY SENSORS
<br /> r THE COMPLETED WORK. E211 POWER AND SYSTEMS PLANS
<br /> BUILDING OCCUPANCIES
<br /> ~r B. EXISTING BUILDING IS FULLY SPRINKLERED. ANY EXISTING FIRE SPRINKLERS AFFECTED BY NEW E311 ENTRY POWER&SYSTEMS PLAN
<br /> $I (MAIN USE) M-MERCANTILE-RETAIL OR WHOLESALE STORES (SALES FLOOR) SECTION 309.1 CONSTRUCTION WILL BE ADJUSTED TO MEET REQUIREMENTS. E321 OFFICE POWER&SYSTEMS PLANS
<br /> (MAIN USE)S-1 -MODERATE-HAZARD STORAGE (STOCK ROOMS/EQUIPEMENT) SECTION 311.2 E381 E&E POWER&SYSTEMS PLANS
<br /> (ACCESSORY USE)A-2-ASSEMBLY (EMPLOYEE LOUNGE/CAFE) SECTION 303.1 C EXTERIOR: BUILDING SIGNAGE, SITE FURNISHING,AND BUILDING PAINTING UPDATES. E385 BEAUTY&PERSONAL CARE POWER&SYSTEMS PLAN
<br /> R..
<br /> (ACCESSORY USE)B-BUSINESS (OFFICES/PHARMACY) SECTION 304.1 E501 ELEVATIONS&CONTROL DIAGRAMS
<br /> SALES FLOOR: INCLUDES STORE FIXTURE,WALL FINISH, FLOOR FINISH,AND LIGHTING
<br /> D. UPDATES. E511 ELECTRICAL DETAILS
<br /> _ {{ ALLOWABLE AREA OCCUPANCIES E521 ELECTRICAL DETAILS
<br /> RESTROOMS:ADA UPDATES AND RETROFITTING OF LIGHTING. E531 ELECTRICAL DETAILS
<br /> ,q f PER CBC TABLE 504.4-TYPE IIB CONSTRUCTION-MERCANTILE-SPRINKLERED,ALLOWABLE HEIGHT=75-FT ABOVE GROUND. E E541 ELECTRICAL DETAILS PROFESSIONAL OF
<br /> n.,
<br /> PER CBC TABLE 504.4-TYPE IIB CONSTRUCTION-MERCANTILE-SPRINKLERED,ALLOWABLE STORIES=3 FITTING ROOMS: RECONFIGURATION OF EXISTING FITTING ROOMS. FULL DECOR UPDATE E601 EQUIPMENT AND LIGHT FIXTURE SCHEDULE RECORD SEAL
<br /> INCLUDES FITTING ROOM PARTITIONS,WALL FINISHES, FLOOR FINISHES,CEILING FEATURES
<br /> ' ';ti. - •
<br /> PER CBC 507.4,THE AREA OF A GROUP M BUILDING NO MORE THAN ONE STORY ABOVE GRADE PLANE OF ANY CONSTRUCTION TYPE, F. AND LIGHTING. E611 ELECTRICAL ONE-LINE DIAGRAM
<br /> SHALL NOT BE LIMITED WHERE THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLER SYSTEM THROUGHOUT IN ACCORDANCE E621 PANELBOARD SCHEDULES
<br /> WITH SECTION 903.3.1.1 AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS THAN 60 FEET IN WIDTH. GUEST SERVICE: INCLUDES RECONFIGURATION OF GUEST SERVICES AREA, STORE FIXTURE, E622 PANELBOARD SCHEDULES
<br /> G WALL FINISH, FLOOR FINISH,CEILING FINISH,AND LIGHTING UPDATES.
<br /> _ HOURLY FIRE-RESISTANCE RATING PER TABLE 601 REQUIRED PROVIDED OFFICES: INCLUDES RECONFIGURATION OF PARTITIONS,WALL FINISH, FLOOR FINISH, CEILING ��SED ARCyz
<br /> (NOTE: EXISTING BUILDING SUPERSTRUCTURE IS STEEL POST AND BEAM-NO BEARING WALLS) FINISH,AND LIGHTING UPDATES. v
<br /> H ROBERT J.SARGENTI
<br /> PRIMARY STRUCTURAL FRAMING 0 0 GROCERY: INCLUDES A CEILING FEATURE ADDITION AND FLOOR FINISH, CEILING FINISH,
<br /> x
<br /> EXTERIOR BEARING WALLS 0 0 I. LIGHTING,AND SIGNAGE UPDATES. NEW AND RELOCATED EXISTING SALES FLOOR REACH-IN
<br /> No. C-31054
<br /> INTERIOR BEARING WALLS 0 N/A COOLERS AND FREEZERS.
<br /> EXTERIOR NONBEARING WALLS AND PARTITIONS 0 0 07/31/19
<br /> INTERIOR NONBEARING WALLS AND PARTITIONS 0 0 STARBUCKS: ELECTRICAL WORK RETROFIT DOWNLIGHT. tp Rene �Q
<br /> FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 0 J. "9TF
<br /> NORTH ROOF CONSTRUCTION AND SECONDARY MEMBERS 0 0 CAFE: ELECTRICAL WORK LIGHTING RETROFIT UPDATES.
<br /> K.
<br /> STOCKROOM: INCLUDES STOCK SHELVING,AND ASSOCIATED LIGHTING RECONFIGURATION.
<br /> PROJECT TEAM: APPLICABLE CODES: EXIT ACCESS TRAVEL DISTANCE L NEW AND RE-USED WALK-IN COOLERS AND FREEZERS ASSOCIATED WITH GROCERY.
<br /> 250 FT FOR"M"OCCUPANCY PER 2016 CBC TABLE 1017.2 FOR SPRINKLERED BUILDINGS
<br /> PROFESSIONALS OF RECORD BUILDING CODE COMMON PATH OF TRAVEL
<br /> ORIGINAL:2007 CALIFORNIA BUILDING CODE PER 2016 CBC TABLE 1006.2.1,75 FEET FOR "M"OCCUPANCY
<br /> ARCHITECT CURRENT:2016 CALIFORNIA BUILDING CODE PER 2016 CBC TABLE 1006.2.1, 100 FEET FOR"B"OCCUPANCY FOR SPRINKLERED BUILDINGS
<br /> SARGENTI ARCHITECTS
<br /> 461 FROM ROAD,SECOND FLOOR CURRENT:2016 CALIFORNIA GREEN BUILDING STANDARDS PER 2016 CBC TABLE 1006.2.1, 100 FEET FOR"S"OCCUPANCY FOR SPRINKLERED BUILDINGS
<br /> PARAMUS, NJ 07652 LOCAL JURISDICTION CODE
<br /> (973)253-9393 ORIGINAL: N/A OCCUPANCY LOAD FACTORS C)
<br /> DOUHA ELLIS, RA
<br /> CURRENT:TRACY MUNICIPAL CODE
<br /> DIRECT: (973)859-9323 ACCESSIBILITY CODE (PER 2016 CBC TABLE 1004.1.2-MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT) co
<br /> E-MAIL: (973)DEL8 9-9323 RCH.COM GENERAL CONTRACTOR NOTES: LO
<br /> ORIGINAL:2008 CALIFORNIA BUILDING STANDARDS MERCANTILE-BASEMENT AND GRADE FLOOR AREAS(SALES) 60 GROSS
<br /> CODE TITLE 24 MERCANTILE-STORAGE,STOCK,SHIPPING AREAS(STORAGE) 300 GROSS
<br /> BUSINESS AREAS(OFFICES, PHARMACY) 100 GROSS
<br /> MEP I REFRIGERATION ENGINEER CURRENT:2016 CALIFORNIA BUILDING CODE, PART 2, ASSEMBLY AREA(LOUNGE,CAFE) 15 NET
<br /> DC ENGINEERING, INC. VOLUME 1
<br /> [REFER TO EGRESS PLANS] SALES FLOOR
<br /> 502 E CORPORATE DRIVE v
<br /> MERIDIAN, IDAHO 83642 MECHANICAL CODE A. REMOVE ALL BEIGE COLOR WALL ARMOR(ACROVYN/KYDEX)FROM GUEST FACING SALES FLOOR
<br /> (406)829-8828 ORIGINAL:2007 CALIFORNIA MECHANICAL CODE WALLS. REPLACE WITH NEW WALL ARMOR COORDINATING WITH ADJACENT DECOR PER CURRENT
<br /> CURRENT:2016 CALIFORNIA MECHANICAL CODE DECOR CRITERIA.
<br /> MECHANICAL I REFRIFERATION PLUMBING FIXTURE COUNT NOTES B. PAINT ALL ADJACENT HM DOORS AND/OR FRAMES TO MATCH ADJACENT WALL COLOR, UNO. U
<br /> RYAN GRAMM PLUMBING CODE C. REPLACE ALL BEIGE TRAFFIC DOORS ON SALES FLOOR WITH RED OR GRAY TRAFFIC DOORS TO
<br /> E-MAIL: RGRAMM@DCENGINEERING.NET MATCH ADJACENT WALL COLOR. Q
<br /> PHONE: (208)493-0073 ORIGINAL:2007 CALIFORNIA PLUMBING CODE PER CPC TABLE 4-1 FOR RETAIL OCCUPANCY
<br /> CURRENT:2016 CALIFORNIA PLUMBING CODE OCCUPANT LOAD PER CALIFORNIA PLUMBING CODE;CHA-TABLE"A" GROUP A=(2,199 SF)/30 SQ.FT. = 73.30 SIDEWALK I SITE
<br /> ELECTRICAL GROUP B=(3,127 SF)/200 SQ.FT.= 15.63
<br /> FIRE I LIFE SAFETY CODE
<br /> BRYAN HUNT A. REPLACE ALL EXISTING SITE FURNISHINGS IN FAIR-TO-GOOD CONDITION WITH NEW, INCLUDING
<br /> 7 SF)/200 SQ.FT.30 441.53
<br /> ,
<br /> =(88 =
<br /> E-MAIL: BHUNT@DCENGINEERING.NET ORIGINAL:2007 CALIFORNIA FIRE CODE GROUP GROUP MM (88,30 SF)/5000 SQ.FT.- 3.52 BUT NOT LIMITED TO, BENCHES,WASTE RECEPTACLES,ASH SNUFFER,AND BIKE RACKS. Q
<br /> PHONE: (208)493-0073 CURRENT:2016 CALIFORNIA FIRE CODE B. PAINT ALL EXISTING RED BOLLARDS,AND RUSTED METAL ON THE EXTERIOR PERIMETER TO
<br /> 534 PEOPLE MATCH EXTERIOR COLOR PALLET; INCLUDING BUT NOT LIMITED TO,STAIR GUARDRAILS, DOORS,
<br /> ELECTRICAL CODE LOAD DISTRIBUTION 50% MALES AND 50% FEMALES FRAMES,TRIM, GARDEN CENTER FENCING, ETC.
<br /> STRUCTURAL ORIGINAL:2007 CALIFORNIA ELECTRICAL CODE DISTRIBUTION COUNT 267 MALES AND 267 FEMALES C. TRIM ALL TREE BRANCHES THAT ARE IN CLOSE PROXIMITY TO AND OBSTRUCTING VISIBILITY OF W
<br /> ERICKSON ROED ASSOCIATES EXISTING SITE OR BUILDING SIGNAGE.
<br /> 2550 UNIVERSITY AVE W,CTE 201-S CURRENT:2016 CALIFORNIA ELECTRICAL CODE
<br /> L, MN 55114 PAUL, PER CPC TABLE 422.1;SUB-NOTE#4, ONE WATER CLOSET MAY BE SUBSTITUTED FOR UNRINALS PROVIDED THE NUMBER OF WATER Uj
<br /> SAINT
<br /> (651 T PAU70) CLOSETS IS NOT REDUCED BY MORE THAN(2/3)THE REQUIRED NUMBER WATER CLOSETS. MECHANICAL EQUIPMENT
<br /> ENERGY/GAS �n
<br /> ORIGINAL:2008 CALIFORNIA ENERGY CODE A. GC AND OSR TO FIELD VERIFY THE EXISTING GENERATOR SIZE AND IF EXISTING LOUVER OPENING `J
<br /> KATIE OLSON,PE CURRENT:2016 CALIFORNIA ENERGY CODE WILL ALLOW FOR REMOVAL.ALSO VERIFY SIZE OF THE NEW GENERATOR AND IF EXISTING LOUVER IS
<br /> DIRECT:(651)414-6140 LARGE ENOUGH FOR INSTALLING NEW GENERATOR. IF THERE IS NO EXISTING LOUVER OR IF ACCESS
<br /> E-MAIL: KOLSON@ERAENG.COM HEALTH I FOOD SERVICE IS RESTRICTED FOR THE INSTALLATION OF NEW GENERATOR CONTACT THE PROJECT ARCHITECT TO z
<br /> ORIGINAL:CALIFORNIA HEALTH AND SAFETY COORDINATE MODIFYING EXTERIOR.WALL FOR ACCESS OF GENERATOR.
<br /> TARGET TEAM COUNTY OF SAN JOAQUIN ENVIRONMENTAL O
<br /> HEALTH
<br /> NICHOLAS ANNONI CURRENT: CALIFORNIA HEALTH AND SAFETY 00
<br /> 50 S 10TH STREET CODE SECTION, DIVISION 104-ENVIRONMENTAL ^'
<br /> SUITE 400,TP3-0783 HEALTH, PART 7, CALIFORNIA RETAIL FOOD CODE, ` V
<br /> MINNEAPOLIS, MN 55403 SECTION 113700 ET SEC. PLUMBING FIXTURE CALCULATIONS
<br /> DIRECT: (612)761-7714 OCCUPANCY TOTAL OCC. WATER LAVATORIES DRINKING
<br /> E-MAIL: NICHOLAS.ANNONI@TARGET.COM CLOSETS FOUNTAINS
<br /> MERCANTILE 534 3 MALE(201-400) 1 FOR EA. (2)WC 1 (31-150) DEFFERED SUBMITTALS:
<br /> BUILDING CLSSIFICATION: 4 FEMALE(201-300) AFTER 150(1)FOR EA. 150
<br /> TOTAL MALE 267 3 2 3
<br /> REQ.'D FEMALE 267 4 2 DEFERRED SUBMITTAL DOCUMENTS SHALL BE SUBMITTED TO THE ARCHITECT-OR
<br /> SITE ZONING TOTAL MALE - 4 3 ENGINEER-OF-RECORD,WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING PROJECT NUMBER: T-0738
<br /> COMMERCIAL PROVIDED FEMALE - 5 4 4 OFFICIAL WITH A NOTATION THAT THEY HAVE BEEN REVIEWED AND HAVE BEEN FOUND TO
<br /> UNISEX 2 2 BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING OR STRUCTURE. THE
<br /> FIRE ZONE OR DISTRICT (1)SERVICE SINK SHALL BE PROVIDED DEFERRED ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL CONFIG: LL
<br /> DOCUMENTS HAVE BEEN REVIEWED AND APPROVED BY THE BUILDING OFFICIAL.
<br /> NONE
<br /> A. FIRE SPRINKLER ALTERATION PLANS DRAWN BY: J.P. RIOS
<br /> SEISMIC DESIGN CATEGORY AUTOMATIC FIRE-EXTINGUISHING SYSTEM AS REQUIRED BY CBC(CALIFORNIA
<br /> D BUILDING CODE)OR CFC(CALIFORNIA FIRE CODE)SECTION 904.2
<br /> • SPRINKLER SYSTEM REQUIRED BY THE CFC(CALIFORNIA FIRE CODE)TABLE CHECKED BY: G.ABREU-GARCIA
<br /> BUILDING OCCUPANCY CLASSIFICATION 3206.2 FOR HIGHER HAZARD COMMODITY IN HIGH PILED STORAGE AREAS
<br /> NON-SEPARATED MIXED USE: M-MERCANTILE,
<br /> S-1 -STOCK;W/ACCESSORY A-2 AND B
<br /> BUILDING CONSTRUCTION TYPE SPECIAL INSPECTIONS::
<br /> II-B,SPRINKLERED
<br /> BUILDING ALLOWABLE FLOOR AREA A. EIFS COVER SHEET
<br /> UNLIMITED(CLOSED MALL)
<br /> ACTUAL BUILDING AREA: 96,096 S.F. B. POST INSTALLED ANCHORS
<br /> AFFECTED AREA OF WORK:85,875 S.F.
<br /> C. FIELD WELDING
<br /> BUILDING ALLOWABLE HEIGHT
<br /> 60'-0"(W/SPRINKLERS),29'-4"ACTUAL EXISTING
<br /> 1/17/2019 3:41:03 PM