Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
SHEET SHEET NAME <br /> 00-GENERAL <br /> G001 COVER SHEET <br /> G002 SITE PLAN(REFERENCE ONLY) <br /> G003 ACCESSIBILITY DETAILS <br /> G004 CAL GREEN <br /> San Joaquin County G005 CAL GREEN <br /> Environmental Health Department <br /> 1868 E. Hazelton Ave. 30_ARCHITECTURAL DEMOLITION <br /> Stockton, CA 95205 <br /> AD111 DEMOLITION FLOOR PLAN <br /> • ` (209) 468-3420 <br /> fioi' <br /> 40-ARCHITECTURAL <br /> APPROVED WITH CONDITIONS A001 GENERAL ARCHITECTURAL INFORMATION <br /> A021 CODE COMPLIANCE PLAN <br /> For conditions, please see approval letter dated: 5-3-21 A214 EIFS SECTIONS&DETAILS TARGET® <br /> A111 FLOOR PLAN <br /> Approved by: ICaG�G�a!?�IG� Ll!?Glai'et Date: May 03, 2021 Al 21 FLOOR FINISH&WALL FINISH PLAN <br /> Al 25 INSULATION AND BLOCKING PLAN 1000 N(COLLET MALL <br /> Al 31 REFLECTED CEILING PLAN MINNEAPOLIS, MN 55403 <br /> Al 33 ENLARGED REFLECTED CEILING PLANS&DETAILS <br /> A201 EXTERIOR ELEVATIONS <br /> A212 ENLARGED EXTERIOR ELEVATION&WALL SECTIONS <br /> A301 ENTRY PLANS, ELEVATIONS&DETAILS <br /> A302 ENTRY MALL PLANS, ELEVATIONS <br /> A303 GUEST SERVICES PLANS&ELEVATIONS <br /> A304 GUEST SERVICE DETAILS <br /> A307 RESTROOM PLAN, ELEVATIONS&DETAILS <br /> A331 OFFICE PLANS I <br /> A332 OFFICE PLANS Li <br /> A335 OFFICE DETAILS <br /> A341 FITTING ROOM PLANS&DETAILS r <br /> A501 INTERIOR DETAILS v <br /> A502 INTERIOR DETAILS A' <br /> A601 PARTITION TYPES&SCHEDULES r <br /> A611 OPENING SCHEDULE&DETAILS <br /> A701 SALES FLOOR ELEVATIONS&DECOR DETAILS <br /> A702 ENLARGED FINISH PLANS&ELEVATIONS r /� <br /> 60 STRUCTURAL v ' <br /> S141 GENERAL STRUCTURAL NOTES,PARTIAL ROOF FRAMING PLANS&DETAILS <br /> 461 FROM ROAD, PARAMUS, NJ 07652 <br /> 62_STRUCTURALFIXTURE TI973.253.9393 ■ WWW.SARGARCH.COM <br /> SR11 STRUCTURAL FIXTURE PLAN <br /> SR51 PALLET RACK ANCHORAGE&DETAILS <br /> SR52 LIGHT DUTY SHELVING ANCHORAGE&DETAILS REVISIONS <br /> SR53 SALES FLOOR GONDOLA ANCHORAGE&DETAILS DATE NO. DESCRIPTION <br /> 01117119 ISSUED FOR PERMIT <br /> 70 PLUMBING <br /> PM01 MECHANICAL SHEET INDEX <br /> PC01 TITLE 24 CODE COMPLIANCE <br /> P111 OVERALL PLUMBING PLAN <br /> P301 JANITOR,NIGHT MAINTENANCE,&LOUNGE PLUMBING PLANS <br /> P411 MARKET PLUMBING PLANS <br /> P431 CONDENSATE VACUUM DETAILS <br /> P601 PLUMBING SCHEDULES&DETAILS <br /> 71 MECHANICAL <br /> M111 OVERALL HVAC PLAN <br /> M301 OFFICES&GUEST SERVICE HVAC PLANS <br /> M321 FITTING ROOMS HVAC PLANS <br /> 2019 RErAIDDEL M601 MECHANICAL SCHEDULES&DETAILS <br /> 72 FIRE PROTECTION <br /> F111 FIRE PROTECTION PLAN <br /> 73-REFRIGERATION <br /> RD01 REFRIGERATION DEMOLITION PLANS <br /> R111 REFRIGERATION SYSTEM PLAN <br /> R401 MARKET AREA CASE SETTING&PIPING PLANS <br /> R511 REFRIGERATION DETAILS <br /> R601 REFRIGERATION SCHEDULES <br /> R602 REFRIGERATION SCHEDULES <br /> R621 REFRIGERATION CONTROLS PLANS <br /> 80-ELECTRICAL <br /> E001 ELECTRICAL COVER SHEET <br /> E002 LIGHTING ENERGY COMPLIANCE <br /> VICINITY MAP: LOCATION MAP: BUILDING CODE SUMMARY: REMODEL SCOPE OF WORK: E004 LIGHTING ENERGY COMPLIANCE <br /> E005 LIGHTING ENERGY COMPLIANCE <br /> MIXED OCCUPANCIES E003 LIGHTING ENERGY COMPLIANCE <br /> E623 PANELBOARD SCHEDULES <br /> THIS BUILDING IS DESIGNED PER IBC SECTION 508.2 ACCESSORY OCCUPANCY,CBC SECTION 508.1 FOR MIXED OCCUPANCIES AND ED111 LIGHTING DEMOLITION PLAN <br /> CBC SECTION 508.3 FOR NON-SEPARATED USE. ED211 POWER&SYSTEMS DEMOLITION PLAN <br /> E111 LIGHTING PLAN <br /> PER CBC SECTION 508.2.4(ACCESSORY USES), NO FIRE SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES(A-2&B) E121 SPECIALTY LIGHTING PLAN <br /> • y ;r •- ,` _ AND THE MAIN OCCUPANCIES(M&S-1). NO ASBESTOS AND NO ASBESTOS-BEARING MATERIALS ARE ALLOWED E124 A&A TRACK LIGHTING PLAN <br /> '* - ON THIS PROJECT <br /> " <br /> .. <br /> PER CBC SECTION 508.3 NONSEPARATED OCCUPANCIES BUILDINGS OR PORTIONS OF BUILDINGS THAT COMPLY WITH THE E131 ENTRY LIGHTING PLAN <br /> PROVISIONS OF THIS SECTION SHALL BE CONSIDERED AS NONSEPARATED OCCUPANCIES. E141 OFFICE LIGHTING PLANS <br /> " `•'` A. ARCHITECTURAL WORK IS LIMITED TO MINOR DEMOLITION AND REPAIR/REPLACEMENT OF <br /> ' PER CBC SECTION 508.3.3 NO SEPARATION IS REQUIRED BETWEEN NON SEPARATED OCCUPANCIES E151 GROCERY,ADULT BEVERAGE&HOME TRACK LIGHTING PLANS <br /> FINISHES.THE EXISTING OCCUPANCY, USE, LIFE SAFETY AND EGRESS ARE NOT IMPACTED BY <br /> 4E161 OCCUPANCY SENSORS <br /> r THE COMPLETED WORK. E211 POWER AND SYSTEMS PLANS <br /> BUILDING OCCUPANCIES <br /> ~r B. EXISTING BUILDING IS FULLY SPRINKLERED. ANY EXISTING FIRE SPRINKLERS AFFECTED BY NEW E311 ENTRY POWER&SYSTEMS PLAN <br /> $I (MAIN USE) M-MERCANTILE-RETAIL OR WHOLESALE STORES (SALES FLOOR) SECTION 309.1 CONSTRUCTION WILL BE ADJUSTED TO MEET REQUIREMENTS. E321 OFFICE POWER&SYSTEMS PLANS <br /> (MAIN USE)S-1 -MODERATE-HAZARD STORAGE (STOCK ROOMS/EQUIPEMENT) SECTION 311.2 E381 E&E POWER&SYSTEMS PLANS <br /> (ACCESSORY USE)A-2-ASSEMBLY (EMPLOYEE LOUNGE/CAFE) SECTION 303.1 C EXTERIOR: BUILDING SIGNAGE, SITE FURNISHING,AND BUILDING PAINTING UPDATES. E385 BEAUTY&PERSONAL CARE POWER&SYSTEMS PLAN <br /> R.. <br /> (ACCESSORY USE)B-BUSINESS (OFFICES/PHARMACY) SECTION 304.1 E501 ELEVATIONS&CONTROL DIAGRAMS <br /> SALES FLOOR: INCLUDES STORE FIXTURE,WALL FINISH, FLOOR FINISH,AND LIGHTING <br /> D. UPDATES. E511 ELECTRICAL DETAILS <br /> _ {{ ALLOWABLE AREA OCCUPANCIES E521 ELECTRICAL DETAILS <br /> RESTROOMS:ADA UPDATES AND RETROFITTING OF LIGHTING. E531 ELECTRICAL DETAILS <br /> ,q f PER CBC TABLE 504.4-TYPE IIB CONSTRUCTION-MERCANTILE-SPRINKLERED,ALLOWABLE HEIGHT=75-FT ABOVE GROUND. E E541 ELECTRICAL DETAILS PROFESSIONAL OF <br /> n., <br /> PER CBC TABLE 504.4-TYPE IIB CONSTRUCTION-MERCANTILE-SPRINKLERED,ALLOWABLE STORIES=3 FITTING ROOMS: RECONFIGURATION OF EXISTING FITTING ROOMS. FULL DECOR UPDATE E601 EQUIPMENT AND LIGHT FIXTURE SCHEDULE RECORD SEAL <br /> INCLUDES FITTING ROOM PARTITIONS,WALL FINISHES, FLOOR FINISHES,CEILING FEATURES <br /> ' ';ti. - • <br /> PER CBC 507.4,THE AREA OF A GROUP M BUILDING NO MORE THAN ONE STORY ABOVE GRADE PLANE OF ANY CONSTRUCTION TYPE, F. AND LIGHTING. E611 ELECTRICAL ONE-LINE DIAGRAM <br /> SHALL NOT BE LIMITED WHERE THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLER SYSTEM THROUGHOUT IN ACCORDANCE E621 PANELBOARD SCHEDULES <br /> WITH SECTION 903.3.1.1 AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS THAN 60 FEET IN WIDTH. GUEST SERVICE: INCLUDES RECONFIGURATION OF GUEST SERVICES AREA, STORE FIXTURE, E622 PANELBOARD SCHEDULES <br /> G WALL FINISH, FLOOR FINISH,CEILING FINISH,AND LIGHTING UPDATES. <br /> _ HOURLY FIRE-RESISTANCE RATING PER TABLE 601 REQUIRED PROVIDED OFFICES: INCLUDES RECONFIGURATION OF PARTITIONS,WALL FINISH, FLOOR FINISH, CEILING ��SED ARCyz <br /> (NOTE: EXISTING BUILDING SUPERSTRUCTURE IS STEEL POST AND BEAM-NO BEARING WALLS) FINISH,AND LIGHTING UPDATES. v <br /> H ROBERT J.SARGENTI <br /> PRIMARY STRUCTURAL FRAMING 0 0 GROCERY: INCLUDES A CEILING FEATURE ADDITION AND FLOOR FINISH, CEILING FINISH, <br /> x <br /> EXTERIOR BEARING WALLS 0 0 I. LIGHTING,AND SIGNAGE UPDATES. NEW AND RELOCATED EXISTING SALES FLOOR REACH-IN <br /> No. C-31054 <br /> INTERIOR BEARING WALLS 0 N/A COOLERS AND FREEZERS. <br /> EXTERIOR NONBEARING WALLS AND PARTITIONS 0 0 07/31/19 <br /> INTERIOR NONBEARING WALLS AND PARTITIONS 0 0 STARBUCKS: ELECTRICAL WORK RETROFIT DOWNLIGHT. tp Rene �Q <br /> FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 0 J. "9TF <br /> NORTH ROOF CONSTRUCTION AND SECONDARY MEMBERS 0 0 CAFE: ELECTRICAL WORK LIGHTING RETROFIT UPDATES. <br /> K. <br /> STOCKROOM: INCLUDES STOCK SHELVING,AND ASSOCIATED LIGHTING RECONFIGURATION. <br /> PROJECT TEAM: APPLICABLE CODES: EXIT ACCESS TRAVEL DISTANCE L NEW AND RE-USED WALK-IN COOLERS AND FREEZERS ASSOCIATED WITH GROCERY. <br /> 250 FT FOR"M"OCCUPANCY PER 2016 CBC TABLE 1017.2 FOR SPRINKLERED BUILDINGS <br /> PROFESSIONALS OF RECORD BUILDING CODE COMMON PATH OF TRAVEL <br /> ORIGINAL:2007 CALIFORNIA BUILDING CODE PER 2016 CBC TABLE 1006.2.1,75 FEET FOR "M"OCCUPANCY <br /> ARCHITECT CURRENT:2016 CALIFORNIA BUILDING CODE PER 2016 CBC TABLE 1006.2.1, 100 FEET FOR"B"OCCUPANCY FOR SPRINKLERED BUILDINGS <br /> SARGENTI ARCHITECTS <br /> 461 FROM ROAD,SECOND FLOOR CURRENT:2016 CALIFORNIA GREEN BUILDING STANDARDS PER 2016 CBC TABLE 1006.2.1, 100 FEET FOR"S"OCCUPANCY FOR SPRINKLERED BUILDINGS <br /> PARAMUS, NJ 07652 LOCAL JURISDICTION CODE <br /> (973)253-9393 ORIGINAL: N/A OCCUPANCY LOAD FACTORS C) <br /> DOUHA ELLIS, RA <br /> CURRENT:TRACY MUNICIPAL CODE <br /> DIRECT: (973)859-9323 ACCESSIBILITY CODE (PER 2016 CBC TABLE 1004.1.2-MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT) co <br /> E-MAIL: (973)DEL8 9-9323 RCH.COM GENERAL CONTRACTOR NOTES: LO <br /> ORIGINAL:2008 CALIFORNIA BUILDING STANDARDS MERCANTILE-BASEMENT AND GRADE FLOOR AREAS(SALES) 60 GROSS <br /> CODE TITLE 24 MERCANTILE-STORAGE,STOCK,SHIPPING AREAS(STORAGE) 300 GROSS <br /> BUSINESS AREAS(OFFICES, PHARMACY) 100 GROSS <br /> MEP I REFRIGERATION ENGINEER CURRENT:2016 CALIFORNIA BUILDING CODE, PART 2, ASSEMBLY AREA(LOUNGE,CAFE) 15 NET <br /> DC ENGINEERING, INC. VOLUME 1 <br /> [REFER TO EGRESS PLANS] SALES FLOOR <br /> 502 E CORPORATE DRIVE v <br /> MERIDIAN, IDAHO 83642 MECHANICAL CODE A. REMOVE ALL BEIGE COLOR WALL ARMOR(ACROVYN/KYDEX)FROM GUEST FACING SALES FLOOR <br /> (406)829-8828 ORIGINAL:2007 CALIFORNIA MECHANICAL CODE WALLS. REPLACE WITH NEW WALL ARMOR COORDINATING WITH ADJACENT DECOR PER CURRENT <br /> CURRENT:2016 CALIFORNIA MECHANICAL CODE DECOR CRITERIA. <br /> MECHANICAL I REFRIFERATION PLUMBING FIXTURE COUNT NOTES B. PAINT ALL ADJACENT HM DOORS AND/OR FRAMES TO MATCH ADJACENT WALL COLOR, UNO. U <br /> RYAN GRAMM PLUMBING CODE C. REPLACE ALL BEIGE TRAFFIC DOORS ON SALES FLOOR WITH RED OR GRAY TRAFFIC DOORS TO <br /> E-MAIL: RGRAMM@DCENGINEERING.NET MATCH ADJACENT WALL COLOR. Q <br /> PHONE: (208)493-0073 ORIGINAL:2007 CALIFORNIA PLUMBING CODE PER CPC TABLE 4-1 FOR RETAIL OCCUPANCY <br /> CURRENT:2016 CALIFORNIA PLUMBING CODE OCCUPANT LOAD PER CALIFORNIA PLUMBING CODE;CHA-TABLE"A" GROUP A=(2,199 SF)/30 SQ.FT. = 73.30 SIDEWALK I SITE <br /> ELECTRICAL GROUP B=(3,127 SF)/200 SQ.FT.= 15.63 <br /> FIRE I LIFE SAFETY CODE <br /> BRYAN HUNT A. REPLACE ALL EXISTING SITE FURNISHINGS IN FAIR-TO-GOOD CONDITION WITH NEW, INCLUDING <br /> 7 SF)/200 SQ.FT.30 441.53 <br /> , <br /> =(88 = <br /> E-MAIL: BHUNT@DCENGINEERING.NET ORIGINAL:2007 CALIFORNIA FIRE CODE GROUP GROUP MM (88,30 SF)/5000 SQ.FT.- 3.52 BUT NOT LIMITED TO, BENCHES,WASTE RECEPTACLES,ASH SNUFFER,AND BIKE RACKS. Q <br /> PHONE: (208)493-0073 CURRENT:2016 CALIFORNIA FIRE CODE B. PAINT ALL EXISTING RED BOLLARDS,AND RUSTED METAL ON THE EXTERIOR PERIMETER TO <br /> 534 PEOPLE MATCH EXTERIOR COLOR PALLET; INCLUDING BUT NOT LIMITED TO,STAIR GUARDRAILS, DOORS, <br /> ELECTRICAL CODE LOAD DISTRIBUTION 50% MALES AND 50% FEMALES FRAMES,TRIM, GARDEN CENTER FENCING, ETC. <br /> STRUCTURAL ORIGINAL:2007 CALIFORNIA ELECTRICAL CODE DISTRIBUTION COUNT 267 MALES AND 267 FEMALES C. TRIM ALL TREE BRANCHES THAT ARE IN CLOSE PROXIMITY TO AND OBSTRUCTING VISIBILITY OF W <br /> ERICKSON ROED ASSOCIATES EXISTING SITE OR BUILDING SIGNAGE. <br /> 2550 UNIVERSITY AVE W,CTE 201-S CURRENT:2016 CALIFORNIA ELECTRICAL CODE <br /> L, MN 55114 PAUL, PER CPC TABLE 422.1;SUB-NOTE#4, ONE WATER CLOSET MAY BE SUBSTITUTED FOR UNRINALS PROVIDED THE NUMBER OF WATER Uj <br /> SAINT <br /> (651 T PAU70) CLOSETS IS NOT REDUCED BY MORE THAN(2/3)THE REQUIRED NUMBER WATER CLOSETS. MECHANICAL EQUIPMENT <br /> ENERGY/GAS �n <br /> ORIGINAL:2008 CALIFORNIA ENERGY CODE A. GC AND OSR TO FIELD VERIFY THE EXISTING GENERATOR SIZE AND IF EXISTING LOUVER OPENING `J <br /> KATIE OLSON,PE CURRENT:2016 CALIFORNIA ENERGY CODE WILL ALLOW FOR REMOVAL.ALSO VERIFY SIZE OF THE NEW GENERATOR AND IF EXISTING LOUVER IS <br /> DIRECT:(651)414-6140 LARGE ENOUGH FOR INSTALLING NEW GENERATOR. IF THERE IS NO EXISTING LOUVER OR IF ACCESS <br /> E-MAIL: KOLSON@ERAENG.COM HEALTH I FOOD SERVICE IS RESTRICTED FOR THE INSTALLATION OF NEW GENERATOR CONTACT THE PROJECT ARCHITECT TO z <br /> ORIGINAL:CALIFORNIA HEALTH AND SAFETY COORDINATE MODIFYING EXTERIOR.WALL FOR ACCESS OF GENERATOR. <br /> TARGET TEAM COUNTY OF SAN JOAQUIN ENVIRONMENTAL O <br /> HEALTH <br /> NICHOLAS ANNONI CURRENT: CALIFORNIA HEALTH AND SAFETY 00 <br /> 50 S 10TH STREET CODE SECTION, DIVISION 104-ENVIRONMENTAL ^' <br /> SUITE 400,TP3-0783 HEALTH, PART 7, CALIFORNIA RETAIL FOOD CODE, ` V <br /> MINNEAPOLIS, MN 55403 SECTION 113700 ET SEC. PLUMBING FIXTURE CALCULATIONS <br /> DIRECT: (612)761-7714 OCCUPANCY TOTAL OCC. WATER LAVATORIES DRINKING <br /> E-MAIL: NICHOLAS.ANNONI@TARGET.COM CLOSETS FOUNTAINS <br /> MERCANTILE 534 3 MALE(201-400) 1 FOR EA. (2)WC 1 (31-150) DEFFERED SUBMITTALS: <br /> BUILDING CLSSIFICATION: 4 FEMALE(201-300) AFTER 150(1)FOR EA. 150 <br /> TOTAL MALE 267 3 2 3 <br /> REQ.'D FEMALE 267 4 2 DEFERRED SUBMITTAL DOCUMENTS SHALL BE SUBMITTED TO THE ARCHITECT-OR <br /> SITE ZONING TOTAL MALE - 4 3 ENGINEER-OF-RECORD,WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING PROJECT NUMBER: T-0738 <br /> COMMERCIAL PROVIDED FEMALE - 5 4 4 OFFICIAL WITH A NOTATION THAT THEY HAVE BEEN REVIEWED AND HAVE BEEN FOUND TO <br /> UNISEX 2 2 BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING OR STRUCTURE. THE <br /> FIRE ZONE OR DISTRICT (1)SERVICE SINK SHALL BE PROVIDED DEFERRED ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL CONFIG: LL <br /> DOCUMENTS HAVE BEEN REVIEWED AND APPROVED BY THE BUILDING OFFICIAL. <br /> NONE <br /> A. FIRE SPRINKLER ALTERATION PLANS DRAWN BY: J.P. RIOS <br /> SEISMIC DESIGN CATEGORY AUTOMATIC FIRE-EXTINGUISHING SYSTEM AS REQUIRED BY CBC(CALIFORNIA <br /> D BUILDING CODE)OR CFC(CALIFORNIA FIRE CODE)SECTION 904.2 <br /> • SPRINKLER SYSTEM REQUIRED BY THE CFC(CALIFORNIA FIRE CODE)TABLE CHECKED BY: G.ABREU-GARCIA <br /> BUILDING OCCUPANCY CLASSIFICATION 3206.2 FOR HIGHER HAZARD COMMODITY IN HIGH PILED STORAGE AREAS <br /> NON-SEPARATED MIXED USE: M-MERCANTILE, <br /> S-1 -STOCK;W/ACCESSORY A-2 AND B <br /> BUILDING CONSTRUCTION TYPE SPECIAL INSPECTIONS:: <br /> II-B,SPRINKLERED <br /> BUILDING ALLOWABLE FLOOR AREA A. EIFS COVER SHEET <br /> UNLIMITED(CLOSED MALL) <br /> ACTUAL BUILDING AREA: 96,096 S.F. B. POST INSTALLED ANCHORS <br /> AFFECTED AREA OF WORK:85,875 S.F. <br /> C. FIELD WELDING <br /> BUILDING ALLOWABLE HEIGHT <br /> 60'-0"(W/SPRINKLERS),29'-4"ACTUAL EXISTING <br /> 1/17/2019 3:41:03 PM <br />