HVAC SYMBOLS PLUMBING / PIPING SYMBOLS SHEET INDEX <br /> PIPE HANGER SCHEDULE <br /> WATER,WASTE,GAS,RWC,AND FIRE PROTECTION PIPING TYPE "H-1 " HANGERS DOUBLE LINE DRAWING PM01 MECHANICAL SHEET INDEX <br /> ITEM INDICATED SYMBOL DESCRIPTION <br /> PIPE HANGER Sch Sch THREADED GROOVED TYPE L PVC/ PC01 TITLE 24 CODE COMPLIANCE <br /> REPRESENTATION P111 OVERALL PLUMBING PLAN <br /> SIZE SPACING 40 10 LIGHT WALL LIGHT WALL COPPER ABS ROOF DECK <br /> P301 JANITOR,NIGHT MAINTENANCE,&LOUNGE PLUMBING PLANS <br /> 1" 8'-0"OR LESS* H-1 H-1 H-1 H-1 H-1 H-1 DUCT (1st FIGURE-SIDE SHOWN 24x20 LAVATORY(MULTI-STATION NOT SHOWN) P411 MARKET PLUMBING PLANS <br /> 2nd FIGURE-SIDE NOT P431 CONDENSATE VACUUM DETAILS TARGET® <br /> 12-0 H-1 H-1 H-1 H-1 N/A N/A SHOWN) <br /> P601 PLUMBING SCHEDULES&DETAILS <br /> 1 1/2" 10'-0"OR LESS* H-1 H-1 H-1 H-1 H-1 H-1 WATER CLOSET MC01 TITLE 24 CODE COMPLIANCE 1000 N ICOLLET MALL <br /> 12'4" H-1 H-1 H-1 H-1 N/A N/A DUCT SECTION 24x12 24"0 M111 OVERALL HVAC PLAN MINNEAPOLIS, MN 55403 <br /> 10URINAL M301 OFFICES&GUEST SERVICE HVAC PLANS <br /> 15-0" H-1 H-1 N/A H-1 N/A N/A BEAM CLAMP TO TOP CHORD OF (SUPPLY) M321 FITTING ROOMS HVAC PLANS <br /> 2" 10'-0"OR LESS* H-1 H-1 H-1 H-1 H-1 H-1 JOIST WITHIN 6"OF PANEL POINT M601 MECHANICAL SCHEDULES&DETAILS <br /> SINK F111 FIRE PROTECTION PLAN <br /> 12'-0" H-1 H-1 H-1 H-1 N/A N/A DUCT SECTION 24x123- <br /> 2 <br /> 24"0 <br /> 15'-0" H-1 H-1 N/A H-1 N/A N/A THREADED ROD (RETURN) <br /> 1/2" 9'-0"OR LESS* H-1 H-1 H 1 H-1 H 1 H 1 JANITORS SINK <br /> 1z <br /> 12'-0" H-2 H-1 H-1 H-1 N/A N/A TURNING <br /> -- _- SUPPLY DUCT TURNING 24"0 DOWN ELECTRIC WATER COOLER <br /> 15'0" H-2 H-1 N/A H-1 N/A N/A -----__ <br /> --___ TURNING UP OR DOWN UP <br /> 3" 10'-0"OR LESS* N/A H-1 H-1 H-1 H-1 H-1 - BAR JOIST/BEAM <br /> O HUB DRAIN DC ENGINEERING <br /> 12-0 N/A H-1 H-2 H-1 N/A N/A TURNING TURNING Careful listening. Dynamic solutions. <br /> RETURN DUCT 24"0 DOWN <br /> wwwl <br /> 15'-0" N/A H-2 N/A H-2 N/A N/A UP --i .d(en neerii7 .net <br /> �_ ______-_---- SWIVEL RING TURNING UP OR DOWN FLOOR DRAIN g g <br /> 4" 4'-0" N/A H-1 N/A H-1 H-1 H-1 Phone:208.288.2181 Project:l8TAR17 <br /> 8'-0" N/A H-1 N/A H-1 H-1 N/A <br /> TURNING TURNING FLOOR SINK <br /> 10'-0" N/A H-2 N/A H-2 H-2 N/A EXHAUST DUCT UP 240 DOWN <br /> TURNING UP OR DOWN <br /> 12'-0" N/A H-2 N/A H-2 H-2 N/A ROOF DRAIN <br /> 15-0" N/A H-2 N/A H-2 N/A N/A <br /> 6" 4-0 N/A H-1 N/A H-1 N/A H-1 TURNING <br /> EXHAUST DUCT TURNING 24"0 \ DOWN �i CLEAN OUT <br /> 8'-0" N/A H-2 N/A H-2 H-1 N/A TURNING UP OR DOWN UP <br /> 10'-0" N/A H-3 N/A H-3 H-1 N/A Iz <br /> FUNNEL DRAIN <br /> 12'-0" N/A H-3 N/A H-3 H-2 N/A TYPE "H-2" HANGERS INCLINED RISE(R)OR DROP(D) <br /> 10) VENT THROUGH ROOF <br /> 15'-0" N/A H-3 N/A H-3 N/A N/A REFER TO PLANS FOR BOD HEIGHTS <br /> 8" 4'4" N/A H-2 N/A N/A H-1 H-2 � WALL HYDRANT/INSIDE HOSE BIBB <br /> 8'-0" N/A H-3 N/A N/A H-1 N/A ROOF DECK <br /> 10'-0" N/A H-3 N/A N/A H-2 N/A24x12 GAS SHUTOFF VALVE <br /> ECCENTRIC DUCT FITTING 20x12 <br /> 12'-0" N/A H-3 N/A N/A N/A N/A <br /> TPRESSURE REGULATOR <br /> 15'-0" N/A H-3 N/A N/A N/A N/A <br /> 101, 41-01, N/A H-3 N/A N/A N/A H-2 INV. EL. <br /> INVERT ELEVATION TAG <br /> -0" N/A H-3 N/A N/A N/A H-3 � X' <br /> CONCENTRIC DUCT FITTING 20x12 24x12 BOD Date No. Description <br /> 12"+ 4' <br /> BEAM CLAMP TO TOP CHORD OF A D BOTTOM OF DUCT ELEVATION TAG 01/17/19 ISSUED FOR PERMIT <br /> JOIST WITHIN 6"OF PANEL POINT <br /> * REFER TO SPECIFICATION FOR MAXIMUM ALLOWABLE HANGER SPACING FOR <br /> TYPE L COPPER AND PVC/ABS PIPING. TOP CONNECTION <br /> N/A=NOT ALLOWED OR NOT APPLICABLE THREADED ROD <br /> 24x12 BALANCING BOTTOM CONNECTION <br /> BRANCH DUCT TAKE-OFF DAMPER <br /> GENERAL NOTES: USING RECTANGULAR <br /> DUCTWORK MAIN 12x10 DROP IN DIRECTION OF FLOW <br /> A. THIS PIPE HANGER SCHEDULE SHOWS MAXIMUM ALLOWABLE HANGER SPACING BASED ON 8"O <br /> PIPE WEIGHT AND STRUCTURAL CONSTRAINTS. REFER TO SPECIFICATION SECTION"BASIC — BAR JOIST/BEAM RISE IN DIRECTION OF FLOW <br /> MECHANICAL MATERIALS AND METHODS"FOR ADDITIONAL PIPE HANGER REQUIREMENTS <br /> INCLUDING REQUIRED HANGER ROD DIAMETER AND MAXIMUM HANGER SPACING BASED <br /> ON PIPE MATERIAL AND PIPE DIAMETER. SWIVEL RING \ �X_ SHUTOFF VALVE <br /> B. SUPPORT ALL PIPING WITHIN 6"OF BAR JOIST TOP CHORD PANEL POINT. LOCATE TOP OF 1 <br /> PIPE AT 6"MINIMUM BELOW ROOF DECK. POWER ROOF VENTILATOR 1 <br /> \ WAFER CHECK VALVE <br /> C. FIRE PROTECTION SPRINKLER PIPING SUPPORT SHALL COMPLY WITH REQUIREMENTS OF <br /> NFPA AND LOCAL CODE AUTHORITIES. <br /> STRAINER <br /> D. DO NOT DEVIATE FROM PIPE HANGER DETAILS AS SHOWN. DEVIATION FROM HANGER <br /> DETAILS MAY VOID JOIST MANUFACTURER'S WARRANTY. DIFFUSERC 500 UNION <br /> E. SEE STRUCTURAL SHEETS FOR ADDITIONAL DETAILS AND INFORMATION. DESCRIPTION C: REFERS TO TYPE <br /> 12": NECK SIZE(SQ OR RD) ���� SWING CHECK VALVE <br /> F. SEE SEISMIC DETAILS ON SHEET P501. <br /> 500: CFM <br /> (REFER TO M601 <br /> FOR DIFFUSER TYPE) FCW FILTERED COLD WATER <br /> TYPE "H-3" HANGERS SUPPLY, RETURN OR EXHAUST 12x8 CW - COLD WATER <br /> REGISTER H 200 <br /> 3/8"HEX NUT DESCRIPTION H: REFERS TO TYPE <br /> WITH 12x8: REGISTER SIZE HW - - HOT WATER <br /> JUMBO ROOF DECK - ROOF DECK - �� 200: CFM <br /> WASHER (REFER TO M601 HWR - - - RECIRCULATING HOT WATER <br /> z TOP CHORD(TYP) 3/8"STRUT NUT WITH FOR REGISTER TYPE) <br /> 3/8"HEX NUT ANDLP LIQUEFIED PETROLEUM <br /> :BEAM BEAM CLAMP(TYP) <br /> JUMBO WASHER BEAM STRUT CHANNEL CEILING RETURN GRILLE <br /> �� �� � <br /> DESCRIPTION F: REFERS TO TYPE V VENT <br /> BAR JOIST SINGLE STRUT 24x12: GRILLE SIZE <br /> CHANNEL OR PIPE <br /> JL L (SIZE PER NFPA) (REFER TO M601 24x12 F SD STORM DRAIN <br /> FOR GRILLE TYPE) <br /> - THREADED ROD <br /> CD CONDENSATE DRAIN <br /> HANGER TRANSFER GRILLE& <br /> WITH SWIVEL DUCTWORK 10"o <br /> ROOF DECK RING ROOF DECK 24x6 F G <br /> NATURAL GAS <br /> DESCRIPTION F: REFERS TO TYPE T/A <br /> 24x6: GRILLE SIZE F 24x6 <br /> 3/8"STRUT NUT WITH (REFER TO M601 T/A: TRANSFER AIR T/A SQUARE TO —GW GREASE WASTE <br /> BEAM �` 3/8"HEX NUT AND BEAM —� � STRUT CHANNEL FOR GRILLE TYPE) ROUND ADAPTER <br /> JUMBO WASHER / BEAM CLAMP(TYP) CWV� <br /> / COMBINATION WASTE&VENT <br /> THREADED ROD �' TRANSFER GRILLE& QROFESS/� <br /> BAR JOIST HANGER WITH BAR JOIST DUCTWORK <br /> SW SANITARY WASTE <br /> SWIVEL RING DESCRIPTION F: REFERS TO TYPE 22"0 �' m <br /> SINGLE STRUT CHANNEL THREADED ROD 24x24: GRILLE SIZE VAC CONDENSATE VACUUM 31885 <br /> OR PIPE(SIZE IN ACCORD HANGER WITH T/A: TRANSFER AIR <br /> WITH NFPA FOR FIRE PROT, SWIVEL RING 24x24 24x24 P: 12/31/19 <br /> JOIST (REFER TO M601 F F <br /> SIZE FOR PIPE LOAD FOR RWC BEAM FOR GRILLE TYPE) T/A T/A RO REVERSE OSMOSIS FILTERED COLD WATER �,�QFCP� �P <br /> qT��F CA F��� <br /> LINEAR SLOT DIFFUSER FLEXIBLE DUCT IRR SITE IRRIGATION <br /> PIPE HANGER DETAILS WITH BOOT <br /> 1 U <br /> PM01 NOT TO SCALE DESCRIPTION K: DIFFUSER TYPE PIPE ANCHOR <br /> 8": BOOT NECK SIZE <br /> 1.0": SLOT WIDTH ' PIPE BREAK <br /> 330: CFM <br /> (REFER TO M601 K 8"-1.0" <br /> 0117/2019 : 12/31/2019 <br /> FOR DIFFUSER TYPE) 330 CONNECT TO EXISTING OR SYSTEMS PROVIDED BY NIC. <br /> 3-5 DUCT DIAMETERS SIZED TO <br /> VARIABLE AIR VOLUME BOX 18"0 BOX INLET,TYPICAL XX OWNER FURNISHED EQUIPMENT SYMBOL <br /> REFER TO SHEET A601 FOR EQUIPMENT <br /> INFORMATION <br /> (SIZE AND SHAPE OF BOX WILL VARY) -L, <br /> 18"0 X X B PLUMBING DRAIN TAG <br /> / 3-5 DUCT DIAMETERS SIZED TO Q <br /> BOX INLET,TYPICAL M <br /> FAN POWERED VARIABLE AIR VOLUME BOX FLEXIBLE M <br /> 18"0 CONNECTOR MECHANICAL SYMBOLS <br /> JOIST � (SIZE AND SHAPE OF BOX WILL VARY) <br /> A Q <br /> A SYMBOL DESCRIPTION U <br /> 18"0 <br /> A BEAM <br /> A /S\ <br /> LU <br /> SMOKE DAMPER <br /> UNIT HEATER <br /> SECTION VIEW <br /> F FIRE DAMPER Q <br /> BEAM CLAMP -------- THERMOSTAT OR TEMPERATURE SENSOR OT BALANCING DAMPER <br /> DIAGONAL ANGLE TEMPERATURE&HUMIDITY SENSOR TH Am MOTORIZED DAMPER 0 <br /> THRU BOLT BETWEEN JOIST BOTTOM TYP OF 2 <br /> CHORD ANGLES.SECURE TIGHT WITH DOUBLE NUT. -- - <br /> BOLT THROUGH ANGLE PIPEH ER �_ DUCT STATIC PRESSURE SENSOR O G GRAVITY DAMPER <br /> DIAGONAL ANGLE AND PIPE CLAMP SEE 1 3 <br /> TYP OF 2 PIPE INSULATION �� PM01 PM01 /C COMBINATION FIRE/SMOKE DAMPER W <br /> BOLT THROUGH ANGLE PIPE H GER �_ W <br /> AND PIPE CLAMP SEE 1 3 <br /> PIPE INSULATION PM01 PM01 PIPE ELEVATION DOOR UNDER CUT r <br /> y MAY VARY �•/ <br /> PIPE ELEVATION_ FIRE PROTECTION SYMBOLS 7 <br /> MAY VARY DOMESTIC WATER PIPE. - - L <br /> SEE PLANS FOR SIZE. BEAM CLAMP ANGLE TO I <br /> DOMESTIC WATER PIPE. PIPE CLAMP WITH NEOPRENE EXISTING BEAM. SYMBOL DESCRIPTION O <br /> SEE PLANS FOR SIZE. JOIST BOTTOM GASKET SECURED TIGHT TO SCRAPE AND REPAIR M0M <br /> CHORD ANGLES PIPE. RUN PIPE INSULATION FIRE PROOFING AT W <br /> OVER PIPE CLAMP. CONNECTION. N <br /> ion 0 <br /> PIPE CLAMP WITH NEOPRENE i i <br /> GASKET SECURED TIGHT TO DIAGONAL F <br /> FIRE PROTECTION PIPING <br /> PIPE. RUN PIPE INSULATION ANGLE \I <br /> OVER PIPE CLAMP. SECTION VIEW SECTION VIEW I <br /> DOMESTIC INSPECTORS TEST CONNECTION <br /> WATER PIPE <br /> DOMESTIC _ _ - BEAM CLAMP TO <br /> WATER PIPE SECTION CUT A-A <br /> THRU BOLT O O <br /> SECTION U AT <br /> BOTTOM E'ANDG THROUGH BEAM ANGLE NOTE: NOT ALL SYMBOLS MAY APPEAR ON DRAWINGS. <br /> BETWEEN JOIST REPAIR FIRE <br /> BOTTOM CHORD PROOFING AT BEAM CLAMP. Project Number T-0738 <br /> ANGLES.TYP. A& <br /> DIAGONAL ® DIAGONAL LL <br /> ANGLE ANGLE <br /> Config: <br /> TYP OF 2 TYP OF 2 p <br /> 30 DEGREE MIN 60 30 DEGREE MIN Drawn By B. S M EAD <br /> DEGREE MAX 4 60 DEGREE MAX PIPE <br /> Checked B <br /> PIPE CLAMP PIPE CLAMP Y J. HAM M <br /> SECURED SECURED INSULATION <br /> TIGHT TO PIPE. TIGHT TO PIPE. <br /> JOIST BOTTOM - ® BOTTOM FLANGE - O GALVANIZED <br /> CHORD ANGLES JOIST OF BEAM BEAM STEEL SHIELD CONSULTANT QUALITY ASSURANCE REVIEW CONFIRMATION STAMP <br /> TYP PARALLEL TO JOISTS PERPENDICULAR TO JOISTS PARALLEL TO BEAMS PERPENDICULAR TO BEAMS MECHANICAL SHEET <br /> PLAN VIEW PLAN VIEW DOCUMENTS REVIEWED BY: ROGER DEAN, P.E. <br /> NOTES: NOTES: HIGH DENSITY INDEX <br /> 00 THIS BRACING DETAIL APPLIES ONLY FOR DOMESTIC WATER PIPE TO REDUCE PIPE MOVEMENT = THIS BRACING DETAIL APPLIES ONLY FOR DOMESTIC WATER PIPE TO REDUCE PIPE MOVEMENT PIPE RING HANGER INSULATION CLEVIS HANGER <br /> DURING WATER USAGE. DURING WATER USAGE. INSERT OR REVIEWERS PHONE: 1-208-493-0049 <br /> O THIS BRACING DOES NOT REPLACE PIPE HANGERS. 00 THIS BRACING DOES NOT REPLACE PIPE HANGERS. WOOD BLOCK <br /> WON INSTALL DOMESTIC WATER PIPE ANCHORS WHERE SHOWN ON DRAWINGS. = INSTALL DOMESTIC WATER PIPE ANCHORS WHERE SHOWN ON DRAWINGS. SEE SPECIFICATIONS REVIEWERS E-MAIL: RDEAN@DCENGINEERING.NET <br /> 2 DOMESTIC WATER PIPE ANCHOR DETAIL - JOIST AND BEAM CONSTRUCTION 3 INSULATED PIPE AT HANGER DETAIL DATE REVIEWED:01/02/2018 <br /> PM01 NOT TO SCALE PM01 NOT TO SCALE <br /> 1/17/2019 1 :23:04 PM <br />