My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEMOLITION GENERAL NOTES: <br /> A. ALL EXISTING DUCTWORK AND PIPING INDICATED ON PLAN WAS TAKEN FROM EXISTING <br /> MECHANICAL PLANS AND/OR LIMITED FIELD OBSERVATION. THE CONTRACTOR SHALL <br /> VERIFY LOCATION OF ALL EXISTING SYSTEMS PRIOR TO CONSTRUCTION AND SHALL <br /> NOTIFY THE OSR OF ANY POTENTIAL CONFLICTS. <br /> B. CONTRACTOR SHALL HAVE A THOROUGH KNOWLEDGE OF ALL DRAWINGS, <br /> SPECIFICATIONS AND EXISTING CONDITIONS PRIOR TO BID. FAILURE TO ACQUIRE SUCH <br /> KNOWLEDGE WILL NOT RELIEVE THE RESPONSIBILITY OF THIS CONTRACTOR FOR <br /> PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE <br /> ALLOWED DUE TO THE CONTRACTORS FAILURE TO BECOME FAMILIAR WITH EXISTING <br /> CONDITIONS. <br /> C. BELOW SLAB(BURIED)PIPING ABANDONED IN PLACE SHALL BE CAPPED, PLUGGED TARGET) <br /> AND CONCEALED. PLUGGING AND CAPPING SHALL BE DONE IN A MANNER AS TO <br /> ALLOW REOPENING AND REUSE LATER. ABOVE SLAB PIPING SHALL NOT BE 1000 N ICOLLET MALL <br /> ABANDONED IN PLACE; REMOVE PIPING BACK TO MAIN WHERE SHOWN ON PLANS. MINNEAPOLIS, MN 55403 <br /> D. PATCH ALL PENETRATIONS WHERE PIPING OR DUCTWORK IS REMOVED. PATCHING <br /> SHALL BE BY GENERAL CONTRACTOR. <br /> E. CONCRETE CUTS(BY GENERAL CONTRACTOR)SHALL BE STRAIGHT AND CLEAN, <br /> REPLACE SLAB WITH CONCRETE FLUSH AND SMOOTH WITH ADJACENT SURFACE. <br /> F. FIELD VERIFY LOCATIONS AND QUANTITY OF ALL EXISTING EQUIPMENT, FIXTURES AND <br /> PIPING NECESSARY TO COMPLETE SCOPE OF WORK. <br /> G / INDICATED TO BE REMOVED-ALL REMOVED EQUIPMENT TO BE <br /> DISPOSED OF BY CONTRACTOR UNLESS NOTED AS <br /> RELOCATED/RETAINED IN DEMOLITION PLANS AND/OR KEYNOTES. D C ENGINEERING <br /> H. R*INDICATES EXISTING CONDITIONS. Careful listening Dynamic solutions. <br /> 3 4 TYP TEXT OF EXISTING CONDITIONS-CONTRACTOR SHALL www.d(engineering.net <br /> VERIFY ALL EXISTING CONDITIONS. Phone:208.288.2181 Project:l8TAR17 <br /> i RTU <br /> B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> F E 8"x6" K. SUBMIT(2)COPIES OF REDLINED AS-BUILT UPDATES.ONE COPY SHALL BE <br /> i RETAINED AT THE STORE. RETURN A SECOND COPY TO THE OSR TO BE <br /> o -- FORWARDED TO THE MECHANICAL ENGINEER. <br /> N �y<� <br /> L. CONTRACTOR SHALL COORDINATE ALL PHASES OF DEMOLITION WITH <br /> ARCHITECTURAL DEMOLITION PLANS. <br /> i <br /> GENERAL NOTES: <br /> 1 (E) 6 1 (E) 15" 1 (E) 24x6 A. VERIFY CEILING LAYOUT PRIOR TO FABRICATING DUCT RUNS AND DROPS. <br /> 50 900 __ x <br /> N <br /> __ __ B. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATION OF GRILLES,REGISTERS <br /> 1 8„ � w AND DIFFUSERS IN CEILING GRID. <br /> 24x24 __ --- r 150 (E) <br /> 6„ C. SEE SHEET M601 FOR GRILLES, REGISTERS,AND DIFFUSERS SCHEDULES. <br /> LIi Lii 1❑ <br /> 10" 10" AC ii 130 (E) D. SEE DETAIL 3/M601 FOR DUCT HANGER DETAILS. <br /> 1 (E) 325 � 1 (E) 325 �(E) 1 i I I I <br /> E. REFER TO SPECIFICATION FOR DUCT INSULATION REQUIREMENTS. <br /> j <� (E)24"x10" (E)12"x16" x r F. COORDINATE DUCTWORK AND DUCTSOX INSTALLATION WITH PIPING AND CONDUIT. <br /> i \ 101, Date No. Description <br /> (E) w \ G. SEE DETAILS 1/M601 AND 2/M601 FOR GRILLE/DIFFUSER INSTALLATION REQUIREMENTS. <br /> 200 <br /> � <br /> KEYNOTES: 01/17/19 ISSUED FOR PERMIT <br /> r \ r r 1❑ EXISTING TO REMAIN. <br /> ` (E)24'x12" (E)24'k16" i I <br /> i (E)18 x12 I .� <br /> , � �2 CONNECT TO EXISTING,VERIFY SIZE AND LOCATION. <br /> w 33 REBALANCE EXISTING AIR DEVICE TO CFM INDICATED. <br /> -- -- <br /> Z-1+--+-- I I I E)20'k16" �� (E)20'x20" _ ® REMOVE EXISTING GRILLE/DIFFUSER AND DEMOLISH ASSOCIATED DUCTWORK SHOWN <br /> V J HATCHED.CAP AIR TIGHT IF NOT REUSED. <br /> 1 (E) 1 <br /> AC Ll 250 ❑5 MOUNT BOTTOM OF EQUIPMENT APPROXIMATELY V-0"ABOVE FINISHED CEILING IN <br /> (E) 3 I I r r ACCESSIBLE LOCATION. <br /> E 10 T --- - r-- <br /> 10 © COOLING ONLY THERMOSTAT.MOUNT AT 60"AFF. <br /> 325 O L <br /> r r r r <br /> x I 10 BALANCING DAMPER. LOCATE IN ACCESSIBLE LOCATION. <br /> V I I I V I I I I I i I i I I I I i <br /> O <br /> 325 L -8 RELOCATED DIFFUSER. BALANCE TO CFM INDICATED. <br /> V I I I V I I I I I i I i I I i � <br /> v i i 10" 24x12 I,-, __ n r �9 REMOVE EXISTING GRILLE/DIFFUSER,CLEAN AND SET ASIDE FOR REINSTALLATION AT <br /> i 1 9 (E) 325 1 (E) 1�1 ❑(E) AC I CV�� L J NEW LOCATION. DEMOLISH ASSOCIATED DUCTWORK SHOWN HATCHED AND CAP AIR <br /> I 3 f TIGHT IF NOT REUSED. <br /> Ld1 10 TEMPORARILY SUSPEND EXISTING GRILLE/DIFFUSER AS REQUIRED FOR CEILING WORK. <br /> REINSTALL IN SAME LOCATION. <br /> 8" 24x6 24x12 10" <br /> 1 (E) 180 1 (E) 4 (E) 325 (E) 4 <br /> 1 OFFICES & GUEST SERVICE HVAC DEMOLITION PLAN <br /> M301 SCALE: 1/4"=V-0" <br /> 3 4 <br /> TT <br /> E 8"x6" <br /> � O - <br /> o QP,OFESS/� <br /> i CONTROL N �y<� �QQ�c� H <br /> ROOM <br /> m <br /> 114 IRCULATION ETL-HR 31885 <br /> i <br /> 108 156 P: 12/31/19 <br /> 101, 6" 15" LU(E,) 24x6 `req��CHAN\0 <br /> OFCA1�F <br /> 3 5 (E) 8 1 (E) 50 1 (E) 900 __ N <br /> 8 1 w <br /> 150'9 <br /> i <br /> 10" 24x24 qC 6" OATS/ <br /> 1 (E) 325 i 1 (E) 325 1 (E) DE) 1 75 (E) 3 L CKERS DATE: 01/17/2019 EXP: 12/31/2019 <br /> 4— 151 <br /> (E)24"x10" (E)12"x16" " <br /> 0 <br /> \ 10 (E) 1 w \ <br /> GUEST 200 <br /> SERVICES 1% 2 g <br /> i <br /> 2 C 2rp <br /> 103 ,140_ <br /> (E)18 x12' (E)24"x12" (E)24"x16" O <br /> �, --- co <br /> N Li <br /> FFi <br /> VT/ <br /> 'I I <br /> (E)20"x16" 1� (E)20'k20" — 2 <br /> I I I <br /> � TF 6,�o i 10"o <br /> i ) 3 AC 3 T <br /> 101, <br /> T250 (E) 1 <br /> 6" <br /> 1 100 CF1 <br /> — <br /> � 12x24 1 <br /> 326 (E) 10 LL 11 F 7 <br /> 10" <br /> I <br /> _ �I � FLEXIBLE k�f� CASH 8tz: � i 275 ^ <br /> �I FULFILLMENT �'� FFICE j 10" TMSC <br /> i 103A 1 (E) 24x12 1040 3 5 275 C 109 <br /> UJ <br /> 1 (E) 880 1 (E) 246 TSC/EQUIPMENT 24x12 W <br /> STORAGE F <br /> 110 ♦rt <br /> 2 OFFICES & GUEST SERVICE HVAC PLAN M301 1' Q <br /> SCALE: 1/4"= -0" <br /> Z <br /> 0 <br /> M0 <br /> W <br /> N <br /> Project Number T-0738 <br /> Config: LL <br /> Drawn By B. SMEAD <br /> Checked By J. HAM M <br /> OFFICES & GUEST <br /> SERVICE HVAC <br /> PLANS <br /> PLAN NORTH <br /> 1/17/2019 1 :22:41 PM <br />