My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC EQUIPMENT RESPONSIBILITY MATRIX <br /> DISCHARGE& <br /> ELECTRICAL EQUIPMENT FURNISH EMS INSTALL EMS EMS CABLE SPACE TEMP AND/OR RETURN TEMP DELIVERY SCHEDULE EMS CONTROL HVAC EMS <br /> EQUIPMENT SPECIFIED MFR FURNISH BY INSTALL BY CONNECTION START UP CABLE CABLE TERMINATION SMOKE DETECTOR HUMIDITY SENSOR SENSOR COORDINATION HARDWARE START UP TESTING&BALANCING OF EQUIPMENT <br /> TRANSFER FAN TF-3 GREENHECK MECH MECH ELEC MECH NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED MECH-SEE NOTE 7 NOT REQUIRED NOT REQUIRED CONTRACTOR'S BALANCING CONTRACTOR,SEE SPECIFICATIONS FOR APPROVED VENDORS <br /> 1. HVAC START UP IS BY MANUFACTURER. <br /> 2. CONTRACTOR TO SELECT TEST AND BALANCE CONTRACTOR FROM TARGET APPROVED TEST AND BALANCE CONTRACTOR LIST LOCATED IN SPECIFICATIONS. <br /> 3. TARGET OWNER'S SITE REPRESENTATIVE TO CONTACT OWNER'S ENERGY MANAGEMENT SYSTEM (EMS)CONTRACTOR TO VERIFY LENGTHS OF EMS CABLE REQUIRED. <br /> 4. SMOKE DETECTORS ARE FURNISHED BY THE ALARMS CONTRACTOR. THE MECHANICAL CONTRACTOR INSTALLS THE SMOKE DETECTORS IN THE DUCTWORK. THE WIRES BETWEEN THE SMOKE DETECTOR AND ROOFTOP UNIT ARE PULLED BY THE ELECTRICAL CONTRACTOR. WIRE TERMINATIONS AT THE UNIT ARE COMPLETED BY THE MECHANICAL CONTRACTOR. WIRE TERMINATIONS AT THE SMOKE DETECTOR ARE <br /> COMPLETED BY THE ALARMS CONTRACTOR. TARGET) <br /> 5. THERMOSTAT FURNISHED BY MANUFACTURER AND INSTALLED BY MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL CONTROL WIRING FROM INDOOR FAN UNIT TO THERMOSTAT AND FROM INDOOR FAN UNIT TO CONDENSING UNIT ACCORDING TO MANUFACTURER'S INSTRUCTIONS. SECONDARY ROOM TEMPERATURE SENSOR AND WIRING FURNISHED BY EMS CONTRACTOR. WIRING <br /> INSTALLED BY ELECTRICAL CONTRACTOR. SENSOR INSTALLED AND TERMINATED BY MECHANICAL CONTRACTOR. <br /> 6. OWNER'S ENERGY MANAGEMENT SYSTEM(EMS)CONTRACTOR PROVIDES REMOTE CHECKOUT AND SUPPORT. MECHANICAL CONTRACTOR SHALL BE PRESENT ON SITE AND IN COMMUNICATION WITH EMS CONTRACTOR TO PERFORM EMS POINT-TO-POINT CHECKOUT PROCESS. 1 000 N ICOLLET MALL <br /> 7. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR DELIVERY COORDINATION AND SHALL INFORM OWNER'S SITE REPRESENTATIVE(OSR)OF DELIVERY SCHEDULE. MINNEAPOLIS, MN 55403 <br /> GRILLES, REGISTERS & DIFFUSERS SCHEDULE - OWNER FURNISHED M7 <br /> VOLUME ��ifA �W <br /> TYPE SERVICE MAKE MODEL DAMPER FRAME FINISH MATERIAL REMARKS <br /> C CEILING DIFFUSER TUTTLE AND S1200-LT-WH --- NOTE 1 WHITE ENAMEL STEEL 24"x24"MODULAR FULL-FACE DIFFUSER WITH ROUND NECK <br /> BAILEY mimm <br /> F RETURN/TRANSFER TUTTLE AND CRE500-SF-02-WH --- NOTE 1 WHITE ENAMEL ALUMINUM SEE PLAN FOR FACE SIZE; 1/2"x1/2"x1/2"EGGCRATE GRID.AVAILABLE FACE SIZES ARE 24"x6",24"x12",24"x24"&24"x48" <br /> GRILLE BAILEY D C ENGINEERING <br /> K LINEAR SLOT DIFFUSER TUTTLE AND AIR-TRAC-CTL-01-C01-WH --- NOTE 1 WHITE ENAMEL ALUMINUM ONE SLOT,48"LONG, INSULATED FACTORY PLENUM.SEE PLAN FOR INLET SIZE AND SLOT WIDTH. PATTERN CONTROLLER ADJUSTED FOR VERTICAL THROW. <br /> BAILEY Careful listening. Dynamic solutions. <br /> cengineering.net <br /> ALL GRILLES, REGISTERS&DIFFUSERS ARE FURNISHED BY OWNER AND INSTALLED BY MECHANICAL CONTRACTOR. QUANTITIES,SIZES AND DELIVERY DATES SHALL BE COORDINATED THROUGH THE TARGET REPRESENTATIVE AT 1-866-667-4822. Phone:208.288.21 www.d(engineering.net <br /> Project:l8TAR17 <br /> 1. PROVIDE LAY-IN FRAME TYPE. <br /> 2. PROVIDE SPF'STEEL PLASTER FRAME'FOR ALL GYP BOARD CEILINGS. <br /> 3. PROVIDE SURFACE MOUNTED FRAME TYPE. <br /> TRANSFER FAN SCHEDULE - NEW <br /> WHEEL ELECTRICAL <br /> AIRFLO TSP DIAMETER <br /> EQUIP NO AREA SERVED MANUFACTURER MODEL W(CFM) ("WG) (IN) RPM DRIVE HP VOLTAGE PHASE FREQUENCY REMARKS <br /> TF 3 TMSC EQUIP 156 GREENHECK SQ-65 140 0.125 7" 1300 DIRECT 0.02 120 1 60 PROVIDE COOLING T-STAT SET TO 750 <br /> Date No. Description <br /> 01/17/19 ISSUED FOR PERMIT <br /> ROD HANGER <br /> STRAP HANGER <br /> BAR JOIST OR <br /> STEEL BEAM <br /> TYPICAL Eq <br /> STEEL ANGLE <br /> DUCT WIDTHS_ SCREW STRAP TO <br /> DUCT WIDTHS LESS THAN 36" DUCT. MINIMUM <br /> 36"OR GREATER 1"STRAP LENGTH <br /> PRE PUNCHED CHANNEL ON UNDERSIDE <br /> SUPPORT FASTENED TO OF DUCT. <br /> CONICAL SPIN IN ROOF DECK TOP OF BAR JOIST. <br /> M7 SALES FLOOR GRILLES AND REGISTER SQUARE TO ROUND PROVIDE SUPPORTS WITH DAMPER TYPICAL TYPICAL. <br /> ADAPTERS PROVIDED BY OWNER WHERE NOTED ON PLAN TO PREVENT SAG <br /> SHEETS,ALL OTHERS SHALL BE CONTRACTOR PROVIDED. BETWEEN HANGERS <br /> � SUPPLY DUCT <br /> MAIN STRAP HANGER <br /> ROD HANGER OR <br /> SEE PLANS FOR <br /> SEE PLANS FOR NECK SIZE � HARD DUCT _J L _J STRAP HANGER <br /> NECK SIZE ELBOW <br /> BAND SAME SIZE ---- <br /> AS STRAP <br /> TOTAL FLEX DUCT HANGER <br /> LENGTH SHALL NOT 36"MAXIMUM GREATER THAN <br /> EXCEED 6 FEET DUCT DIAMETER 36"DUCT DIAMETER <br /> GENERAL NOTES: FESS/1 <br /> GRILLE OR A. REFER TO"SMACNA HVAC DUCT CONSTRUCTION STANDARDS"FOR HANGER REQUIREMENTS, <br /> H. <br /> REGISTER GRILLE OR INCLUDING SIZES OF STRAP HANGERS, ROD HANGERS, STEEL ANGLES AND FASTENERS. c� <br /> BELOW REGISTER — MINIMUM OF ONE DUCT DIAMETER co <br /> 12x12,24x24 OR DUCT COLLAR OF STRAIGHT DUCT TO INLET OF B. SUPPORT FROM BAR JOIST TOP CHORD PANEL POINT. <br /> 6x24 OR 12x24 BELOW / 31885 <br /> 24"x48"(18"x30"NECK) CONNECTING f DIFFUSER, OR PROVIDE EQUALIZING C. MAXIMUM LOAD ON ANY PANEL IS 100 LBS, UNLESS APPROVED BY STRUCTURAL P: 12/31/19 <br /> STRAP GRID AT DIFFUSER ENGINEER. SEE STRUCTURAL FOR ADDITIONAL REQUIREMENTS. <br /> NOTE: D. SEE 5/M501 FOR SEISMIC BRACING DETAIL. `rTq�F�HAN\GP���P <br /> MAXIMUM OF 18"OF FLEX DUCT MAY BE USED FOR FINAL CONNECTION. DIFFUSERTF <br /> E. DO NOT INSTALL DUCTWORK CLOSER THAN 8"TO ANY WATER, FIRE PROTECTION, OR FC <br /> GAS PIPING. <br /> 1 GRILLE & REGISTER BOOT 2 DIFFUSER FLEXIBLE DUCT CONNECTION 3 DUCT HANGERS <br /> M601 SCALE: NOT TO SCALE M601 SCALE: NOT TO SCALE M601 SCALE: NOT TO SCALE <br /> DATE: 01/17/2019 EXP: 12/31/2019 <br /> UJco <br /> Ln <br /> Q <br /> a: <br /> U <br /> U <br /> Q <br /> U °C <br /> Q <br /> OC 0 <br /> Lu <br /> LU <br /> _J <br /> PEI CD <br /> Q <br /> z <br /> 0 <br /> 0 <br /> 00 <br /> N <br /> Project Number T-0738 <br /> Config: LL <br /> Drawn By B. SMEAD <br /> Checked By J. HAM M <br /> MECHANICAL <br /> SCHEDULES & <br /> DETAILS <br /> M601 <br /> 1/17/2019 1 :22:49 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.