Laserfiche WebLink
ELECTRICAL SYMBOL LIST ONE-LINE DIAGRAM SYMBOLS ABBREVIATIONS LIST GENERAL NOTES <br /> Electrical Sheet Index A. MATERIALS, PRODUCTS, DEVICES, FIXTURES, FORMS OR TYPES <br /> Sheet ❑ KEY NOTE WATERFLOW SWITCH PANEL PANEL (E) EXISTING OF CONSTRUCTION INCLUDED IN THESE SPECIFICATIONS SHALL <br /> X (R) RELOCATED MEET OR EXCEED THE REQUIREMENTS OF CALIFORNIA <br /> Number Sheet Name O DESIGNATES OWNER SUPPLIED EQUIPMENT. �, ^ ELECTRICAL CODE(CEC),AMERICAN NATIONAL STANDARD <br /> E001 ELECTRICAL COVER SHEET REFER TO SHEET A601 FOR OWNER FURNISHED �% TAMPER VALVE SWITCH (RE) REPLACED INSTITUTE(ANSI), INSTITUTE OF ELECTRICAL AND ELECTRONICS <br /> E002 LIGHTING ENERGY COMPLIANCE EQUIPMENT SCHEDULE. A AMPERES ENGINEERS(IEEE)AND NATIONAL ELECTRICAL MANUFACTURING <br /> E003 LIGHTING ENERGY COMPLIANCEMULTIPLE SYMBOLS ON BRACKET INDICATE O DOOR HOLDER AC ABOVE COUNTER ASSOCIATION(NEMA).E004 LIGHTING ENERGY COMPLIANCE ALL DEVICES UNDER ONE COVER PLATE. U3 BELL AMPERE FRAME BELL-90"AFF UNO AFF ABOVE FINISHED FLOOR B. MATERIALS AND EQUIPMENT SHALL BE LISTED AND APPROVED <br /> E005 LIGHTING ENERGY COMPLIANCE INCANDESCENT, HID, CFL OR LED LUMINAIRE BY A NATIONALLY RECOGNIZED INDEPENDENT TESTING TARGET <br /> ED111 LIGHTING DEMOLITION PLAN I-�/ >BUZZER-90"AFF UAFG ABOVE FINISHED GRADE NO XX CIRCUIT BREAKER AHJ AUTHORITY HAVING JURISDICTION LABORATORY AS CONFORMING TO THEIR STANDARDS. 1 OOO N ICOLLET MALL <br /> ED211 POWER&SYSTEMS DEMOLITION PLAN � � � ® � / <br /> E111 LIGHTING PLAN FLUORESCENT OR LED LUMINAIRE SPEAKER-CEILING FLUSH MOUNT AT AMP TRIP C. WIRE, CABLES,AND INSULATIONS SHALL CONFORM TO ICER- MINNEAPOLIS, MN 55403 <br /> S <br /> E121 SPECIALTY LIGHTING PLAN TRACK TYPE AWG AMERICAN WIRE GAUGE NEMA AND 2014 NEC AS AMENDED BY 2016 CALIFORNIA <br /> E124 A&A TRACK LIGHTING PLAN D CONTROL PANEL BMS BUILDING MANAGEMENT SYSTEM ELECTRICAL CODE STANDARDS AND SPECIFICATIONS. USE NEW <br /> 1 BW BLANKET WARMER WIRE AND DELIVER TO THE JOB SITE IN COILS OR ON REELS. <br /> E131 ENTRY LIGHTING PLANS TRACK LIGHT T#-#— TRACK LENGTH EACH COIL/OR REEL SHALL HAVE A LABEL WITH THE E141 OFFICE LIGHTING PLANS # CIRCUIT NUMBER LP PANELBOARD FUSE C CONDUIT MANUFACTURER'S NAME,TRADE NAME OF WIRE,SIZE OF WIRE <br /> E151 GROCERY,ADULT BEVERAGE&HOME TRACK LIGHTING PLANS CB CIRCUIT BREAKER AND UL LABEL. <br /> E161 OCCUPANCY SENSORSCC CRASH CART <br /> E211 POWER AND SYSTEMS PLANS <br /> INDICATES EMERGENCY LIGHTING ® HL PANELBOARD CKT CIRCUIT D. ALL ELECTRICAL EQUIPMENT AND WIRING SHALL BE LISTED AND <br /> E311 ENTRY POWER&SYSTEMS PLANCL CRITICAL LOAD LABELED BY AN APPROVED AGENCY. INSTALLATION SHALL BE IN <br /> ILLUMINATED EXIT SIGN-CEILING/WALL(SHADED ® HP&LD PANELBOARD DISC DISCONNECT CM CEILING MOUNTED ACCORDANCE WITH APPROVED LISTING. <br /> E321 OFFICE POWER&SYSTEMS PLANS (0 H�gI QUADRANT INDICATES FACE(S). PROVIDE W/RTU CO CONDUIT ONLY, PROVIDE PULL-LINE E. EMERGENCY LIGHTING ILLUMINATION FOR THIS STORE IS D C ENGINEERING <br /> E381 E&E POWER&SYSTEMS PLANS � DIRECTIONAL ARROWS WHERE INDICATED. �T TRANSFORMER D MECHANICAL DUCT-MOUNTED DEVICE <br /> E385 BEAUTY&PERSONAL CARE POWER&SYSTEMS PLAN POWERED FROM AN EXISTING EMERGENCY ELECTRICAL Careful listening. Dynamic solutions. <br /> E501 ELEVATIONS&CONTROL DIAGRAMS POLE MOUNTED LUMINAIRE MAGNETIC MOTOR STARTER <br /> DC DIRECT CURRENT SYSTEM. EXISTING PATHS OF EGRESS AND EXISTING 9" y <br /> �� ® <br /> l <br /> l <br /> DET DETAIL EMERGENCY LIGHTS ARE EXISTING TO REMAIN. IN THE EVENT WWW.dcen neern net <br /> E511 ELECTRICAL DETAILS E EMERGENCY/CRITICAL CARE OF A POWER SUPPLY FAILURE,THE EMERGENCY ELECTRICAL g 9 <br /> E521 ELECTRICAL DETAILS SAFETY SWITCH(POLES NOTED, F INDICATES SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES,LOBBY, <br /> E531 ELECTRICAL DETAILS Phone:208.288.2181 Project:18TAR17 <br /> I-- J� WALL MOUNT JUNCTION BOX- 18"AFF UNO � FUSED, SIZE AS NOTED). EF EXHAUST FAN , <br /> OR CABINET MOUNT JUNCTION BOX EL EMERGENCY LIGHT CORRIDOR, EXTERIOR DOOR LANDING. THE EMERGENCY <br /> E541 ELECTRICAL DETAILS FUSED SWITCH POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF <br /> E601 EQUIPMENT AND LIGHT FIXTURE SCHEDULE COMBINATION STARTER/SAFETY SWITCH EWC ELECTRIC WATER COOLER <br /> NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE <br /> O CEILING MOUNT JUNCTION BOX EWH ELECTRIC WATER HEATER BATTERIES,UNIT EQUIPMENT,OR AN ON-SITE GENERATOR. <br /> E611 ELECTRICAL ONE-LINE DIAGRAM A = VIDEO DISTRIBUTION SYSTEM F FUSE INITIAL ILLUMINATION AVERAGE OF 1 FOOT-CANDLE AND A <br /> E621 PANELBOARD SCHEDULES CRT = NETWORK SYSTEM PUSH BUTTON STATION FACP FIRE ALARM CONTROL PANEL MINIMUM 0.1 FOOT-CANDLE AT FLOOR LEVEL. (CBC SECTION <br /> E622 PANELBOARD SCHEDULES E = ELECTRONIC POINT OF SALE(EPOS)SYSTEM 1006.3) <br /> F = FIRE ALARM SYSTEM FVNR FULL VOLTAGE NON-REVERSING <br /> E623 PANELBOARD SCHEDULES P = PAGING SYSTEM MOTOR CONNECTION DRAW OUT CIRCUIT BREAKER FRAME G/GND GROUND <br /> S = SECURITY SYSTEM F. INSTALL OWNER FURNISHED CIRCUIT BREAKERS OR FUSES IN <br /> GFI GROUND FAULT INTERRUPTION EXISTING PANELBOARDS AS REQUIRED TO FEED CIRCUITRY AS <br /> T = LOW VOLTAGE THERMOSTAT-96"AFF UNO O DAMPER MOTOR GFP GROUND FAULT PROTECTION SHOWN ON PLANS OR SHOWN IN SCHEDULES. <br /> V1 = SINGLE'F'CONNECTOR VIDEO DIST. <br /> COVERPLATE LINE VOLTAGE THERMOSTAT-48"AFF UNO H HEAT <br /> V2 = DUPLEX'FCONNECTOR VIDEO DIST. HH HANDHOLE G. REWORK(RE-ARRANGE)CIRCUIT BREAKERS WITHIN EXISTING <br /> COVERPLATE HID HIGH INTENSITY DISCHARGE PANELBOARDS TO ACCEPT NEW LOAD CIRCUIT BREAKERS AS <br /> OS = OCCUPANCY MOTION SENSOR SWITCH TEMPERATURE SENSOR,96"AFF LINO INDIVIDUAL BREAKER FRAME REQUIRED. <br /> TS HOA HAND OFF AUTO <br /> H = DOOR HOLDER <br /> PS = PHOTO SENSOR HP HOUSE PHONE H. EXISTING CIRCUIT NUMBERS,JUNCTION BOXES,AND HOMERUNS <br /> RS R-NET SENSOR,48"AFF UNO HVAC HEATING,VENTILATING, &AIR CONDITIONING ARE SHOWN FOR REFERENCE ONLY AND WERE OBTAINED FROM <br /> Room Names&Numbers SINGLE RECEPTACLE-18"AFF UNOI IONIZATION EXISTING PLANS. FIELD VERIFY EXISTING CONDITIONS. <br /> LP 1 BRANCH CIRCUIT HOME RUN TO PANELBOARD(UPPER CODE-PANEL M METER IC INTERRUPTING CAPACITY <br /> Number Name 1,3,5 ID, LOWER NUMERALS IDENTIFY CIRCUIT NUMBERS)(NOTE:WITHOUT ID IN-DUCT I. REFER TO DEMO PLANS FOR ELECTRICAL DEMOLITION. <br /> 1 Room DUPLEX RECEPTACLE-18"AFF UNO FURTHER IDENTIFICATION SYMBOL INDICATES 1/2"CONDUIT WITH 2#12 AM METER IG ISOLATED GROUND J. COORDINATE POWER OUTAGES WITH OSR 24 HOURS IN <br /> 101 ENTRY VESTIBULE (SSR-DENOTES SURGE SUPPRESSION) AWG CONDUCTORS. AM <br /> 101A CARTS (GFCI-GROUND FAULT INTERRUPTER) X"C-X#X,X#XG - GROUND CONDUCTOR SIZE J/JB JUNCTION BOX ADVANCE. <br /> (WP-WEATHER PROOF W/WHILE IN USE COVER) KW KILOWATT <br /> 101B EXIT VESTIBULE (USB-DENOTES USB) RACEWAY SIZE CONDUCTOR SIZE GVOLT METER <br /> 102 SALES CONDUCTOR QUANTITY KWH KILOWATT HOUR K. INSTALL OWNER FURNISHED CIRCUIT BREAKER(E12)HANDLE <br /> 103 GUEST SERVICES QUADRUPLEX RECEPTACLE 18"AFF UNO M MAGNETIC CONTACTOR COIL TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF Date No. Description <br /> 103A FLEXIBLE FULFILLMENT CONDUIT CONCEALED IN CEILING OR WALL <br /> KIRK KEY LOCK MB MAIN BREAKER MULTIWIRE BRANCH CIRCUITS PER CEC 210.4. 01/17/2019 PERMIT SET <br /> MCC MOTOR CONTROL CENTER L. INSTALL NEW CIRCUIT BREAKERS WITH INTERRUPTING RATINGS <br /> 104 CASH OFFICE OPTIONAL/EMERGENCY RECEPTACLE-18"AFF UNO GFP GROUND FAULT PROTECTION MH MANHOLE MATCHING OR GREATER THAN EXISTING EQUIPMENT. <br /> 104A CASH OFFICE VESTIBULE CONDUIT CONCEALED IN FLOOR <br /> MLO MAIN LUGS ONLY <br /> 105 FITTING ROOM OPTIONAL/EMERGENCY RECEPTACLE- 18"AFF UNO <br /> 105A RESHOP CONDUIT EXPOSED TVSS TRANSIENT VOLTAGE SURGE SUPRESSION MS MOTOR STARTER M HOLDERS. <br /> S SHALL BE PROVIDED WITH REJECTION TYPE FUSE <br /> MW MICROWAVE <br /> 105B FITTING ROOM LOUNGE OPTIONAL/UPS RECEPTACLE-18"AFF LINO N NEUTRAL <br /> ST SHUNT TRIP COIL N. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO <br /> 107 CIRCULATION CONDUIT RUN UNDERGROUND(SLOPE TO DRAIN <br /> TO PULL BOXES). NC NORMALLY CLOSED OWNERS FIXTURE DRAWINGS) FOR FINAL LAYOUT. <br /> 108 CIRCULATION CH SPECIAL-PURPOSE RECEPTACLE-18"AFF UNO NCL NON CRITICAL LOAD <br /> 109 TMSC KWH KILOWATT HOUR METER NEC NATIONAL ELECTRICAL CODE 0. REPLACE ALL DEFECTIVE, MISSING, BROKEN OR DAMAGED <br /> 110 TSC/EQUIPMENT STORAGE SPLIT WIRE RECEPTACLE-18"AFF UNO CONDUIT TURNED UP <br /> 111 AP OFFICE KVNO NORMALLY OPEN <br /> AR KILOVAR DEMAND METER NIC NOT IN CONTRACT DUN UNKNOWN,CONEVICES AND OTRACTOR S VER PLATES.ALL VERIFY USE HERE IAND LOADSNG ARE <br /> E <br /> 111A CCTV <—PS MULTIOUTLET ASSEMBLY,ARROWS DEFINE THE CONDUIT TURNED DOWN NTS NOT TO SCALE BUILDING AS-BUILT DRAWINGS, PANEL SCHEDULES OR 113 EXTERIOR STORAGE LIMITS OF THE INSTALLATION. TEST TEST BLOCK OFCI OWNER FURNISHED CONTRACTOR INSTALLED DIRECTORIES. <br /> 114 CONTROL ROOM RECEPTACLES 12"OC UNO CONDUIT CAPPED OR BUSHED OFME OWNER FURNISHED MATERIALS& EQUIPMENT P. IF LOAD IS NOT USED AND WILL NOT BE REQUIRED AFTER <br /> 115 WOMEN OVERHEAD SERVICE DROP OL OVERLOAD REMODEL, LABEL THE BREAKER AS"SPARE"AND REMOVE <br /> 116 MEN CLOCK HANGER RECEPTACLE 84"AFF UNO BRANCH CIRCUIT HOME RUN TO PANELBOARD OS OCCUPANCY SENSOR RELATED CONDUCTORS, DEVICES, BOXES AND CONDUIT WHERE <br /> 117 CIRCULATION LP 1 (UPPER CODE-PANEL ID, LOWER NUMERALS <br /> OSR ON SITE REPRESENTATIVE ACCESSIBLE. <br /> 117A CIRCULATION A FLOOR BOX SYSTEMS(LETTER DENOTES OUTLET 1,213 IDENTIFY CIRCUIT NUMBERS) P PHOTO Q. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS <br /> 118 CIRCULATION TYPE,SEE DETAILS) TRANSFER SWITCH PC PHOTOCELL REGARDING NEW FLOOR, CEILING OR WALL FINISHES. REMOVE <br /> 119 JANITOR DEVICE WITH PANEL/CIRCUIT INDICATOR PVC POLYVINYL CHLORIDE AND REPLACE ALL DEVICES AND COVER PLATES WHERE NEW <br /> 2#10&#10G <br /> 120 FOOD SERV STORAGE Z POWER POLE-LETTER DENOTES TYPE 35 AND SPECIAL WIRING REQUIREMENTS NOTED RCPT RECEPTACLE FINISHES ARE PROVIDED. FURNISH AND INSTALL ANY BOX <br /> 2#10& <br /> 120A FOOD PREP (axl) GUTTER RE: REFER TO EXTENSIONS AND CONDUCTORS AS NECESSARY TO <br /> 122 COFFEE SALES s4 SINGLE-POLE SINGLE-THROW SWITCH-44"AFF UNO G EQUIPMENT GROUND REF REFRIGERATOR ACCOMMODATE NEW FINISHES. <br /> 123 FOOD SERVING SPST SINGLE POLE SINGLE THROW <br /> �_ R. KEEP ALL DEPARTMENTS OPERATIONAL DURING <br /> 124 FOOD SEATING - GROUND CONNECTION AS NOTED METER AND BASE ST SHUNT TRIP CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR <br /> 125 STORAGE s� 2 TWO-POLE SINGLE-THROW SWITCH-44"AFF UNO __ TC TIME CLOCK PROVIDING ALL TEMPORARY/CONSTRUCTION LIGHTING AND <br /> � LOW VOLTAGE CABLE <br /> 126 PHARMACY NEUTRAL NEUTRAL TDR TIME DELAY RELAY POWER DURING REMODEL AS NECESSARY FOR CONTINUED <br /> 127 FAMILY RESTROOM s� 3 THREE-WAY SWITCH 44"AFF UNO <br /> TJB TERMINAL JUNCTION BOX OPERATION OF ALL STORE FUNCTIONS. <br /> 130 COMPACTOR/BALER4 FOUR-WAY SWITCH-44"AFF UNO EXISTING CONDUIT TO BE DEMOLISHED PM POWER MONITORING TSP TWISTED SHIELDED PAIR S. A SITE VISIT PRIOR TO BID IS MANDATORY TO DETERMINE <br /> � <br /> 131 RECEIVING TTB TELEPHONE TERMINAL BOARD EXISTING CONDITIONS. CONTRACTOR MAY REUSE EXISTING <br /> 133 MARKING D INDICATES EXISTING DEVICE TO REMAIN TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER <br /> � P SWITCH AND PILOT LIGHT-44"AFF UNO WIRING AND/OR CONDUIT SYSTEMS PROVIDED:ALL ITEMS <br /> 134 WATER SERVICE NOTE: PILOT LIGHT IS ON WHEN SWITCH IS ON TRANSFORMER TYP TYPICAL REUSED ARE IN CONFORMANCE WITH GIVEN SPECIFICATIONS. <br /> 138 ELECTRICAL 1�.1 SYMBOLS SHOWN DASHED,OR KEYNOTED: INDICATES EXISTING UH UNIT HEATER <br /> 138A ELECT.SERVICE ROOM k- K KEY-OPERATED SWITCH-44"AFF UNO DEVICE TO BE DEMOLISHED AND/OR RELOCATED UNO UNLESS NOTED OTHERWISE T. ALL CONDUIT, BOXES, ETC.ARE PROPERLY SUPPORTED AND <br /> M = MOMENTARY CONTACT,SPDT V VOLT SATISFACTORY TO THE APPLICABLE AUTHORITIES AND OWNER <br /> 139 NIGHT MAINT HOA= HAND-OFF-AUTO SWITCH R R = REPRESENTATIVE. REFER TO DETAILS 10, 11, 12,&13 ON E511. <br /> 140 DAY MAI NT SC = SPEED CONTROL 0 SYMBOLS SHOWN WITH LETTER"R"INDICATES RELOCATED DEVICE VA VOLT AMPERE <br /> 141 CIRCULATION MSS= MOTOR STARTER SWITCH MOTOR WG PROVIDE PROTECTIVE WIRE GUARD U. ALL FLEXIBLE CONDUIT, BOXES, ETC.ARE PROPERLY <br /> 142 FIXTURE STORAGE OS = OCCUPANCY(MOTION)SENSOR SWITCH SYMBOLS SHOWN WITH STANDARD TEXT INDICATES NEW DEVICE WP WEATHER PROOF/NEMA 3R SUPPORTED AND SATISFACTORY TO THE APPLICABLE <br /> 143 RESTROOM D = DIMMER SWITCH(WATTAGE AS NOTED.) XX/# XX XFMR TRANSFORMER AUTHORITIES AND OWNER REPRESENTATIVE. REFER TO DETAILS <br /> 146 ELECTRONIC STOCK p--I TELEPHONE OUTLET- 18"AFF LINO 18,&19 ON E511. SEE SPECIFICATION 26 0529. <br /> 147 STOCK WITH 3/4"EMPTY CONDUIT TO ABOVE V. CONSIDERABLE EFFORT HAS BEEN MADE TO PROVIDE ALL <br /> 151 COATS/LOCKERS SUSPENDED CEILING OR TO JOIST SPACE NECESSARY INFORMATION TO REFLECT CURRENT CONDITIONS <br /> 154 ELECTRICAL IN UNFINISHED SPACES. AND REQUIREMENTS WITHIN THE SCOPE OF THIS PROJECT. <br /> 156 ETL-HR CONTRACTOR SHALL BE RESPONSIBLE TO FIELD-VERIFY ALL <br /> 157 LOUNGE W D-i TELEPHONE OUTLET-44"AFF LINO INFORMATION. CONTRACTOR SHALL ALSO HAVE THE LATITUDE <br /> 158 TRAINING WITH 3/4"EMPTY CONDUIT TO ABOVE TO ADJUST CIRCUIT ASSIGNMENTS WITHIN AND BETWEEN ALL <br /> 160 STORAGE SUSPENDED CEILING OR TO JOIST SPACE PANELS AS REQUIRED FOR A COMPLETELY OPERATIONAL AND <br /> JUNCTION BOX NO CLOSER THAN 4"FROM FINISHED PROJECT. Q <br /> 161 STL OFFICE FINISHED DOOR FRAMEIN UNFINISHED SPACES. � GO,q <br /> 162 OPEN OFFICE W. PHASE BALANCING TO WITHIN+/-10% IS DESIRED, BUT PHASE - <br /> 163 CONFERENCE D I DATA OUTLET- 18"LINO WITH 3/4"EMPTY BALANCING TO WITHIN +/-20% IS MANDATORY. 181 Z m <br /> 164 STORAGE CONDUIT TO ABOVE SUSPENDED CEILING OR c 1 3 <br /> TO JOIST SPACE IN UNFINISHED SPACES. X. CONTRACTOR SHALL PROVIDE TO THE OWNER AN UPDATED AND <br /> 180 DAIRY COOLER ACCURATE SET OF BUILDING AS-BUILT DRAWINGS. INCLUDED <br /> 181 FREEZERSHALL BE COMPLETED AND CORRECTED PANEL SCHEDULES 9F�FCTR�OP���P <br /> TELEPHONE&DATA OUTLET-18"UNO WITH <br /> 182 MEAT COOLER 3/4"EMPTY CONDUIT TO ABOVE SUSPENDED AND/OR DIRECTORIES AS NECESSARY FOR OWNER �FOF CA��FO� <br /> 183 PRODUCE COOLER CEILING OR TO JOIST SPACE IN UNFINISHED COORDINATION.THIS APPLIES TO ALL CIRCUITS, EQUIPMENT AND <br /> 184 DRY PRODUCE/LABELING ROOM SPACES. DEVICES THROUGHOUT THE STORE. <br /> 185 VACUUM PUMP ROOM Y. PROVIDE SUPPORT FOR LOW VOLTAGE CABLING PER DETAILS 9, <br /> NOTE: DIMENSIONS ARE TO CENTERLINE OF DEVICE OR BOX UNO. 15, 16,AND 17 ON E511. REFER TO SPECIFICATION 26 0529 AND 26 <br /> 1/17/2019 <br /> 0519. <br /> Z. CONTRACTOR SHALL PROVIDE TO THE OWNER AN UPDATED AND <br /> ACCURATE SET OF BUILDING AS-BUILT DRAWINGS. INCLUDED <br /> SHALL BE COMPLETED AND CORRECTED PANEL SCHEDULES <br /> AND/OR DIRECTORIES AS NECESSARY FOR OWNER O <br /> COORDINATION.THIS APPLIES TO ALL CIRCUITS, EQUIPMENT AND <br /> DEVICES THROUGHOUT THE STORE. M <br /> LO <br /> AA. PROVIDE SUPPORT FOR LOW VOLTAGE CABLING PER DETAILS 9, <br /> 15,16,AND 17 ON E511. REFER TO SPECIFICATION 26 0529 AND 26 <br /> 0519. <br /> BB. REFER TO 9/E511 FOR LOW VOLTAGE SUPPORT REQUIREMENTS. LU Z <br /> CC. DIMMING SWITCHES AS SHOWN IN THESE PLANS ARE TO <br /> FUNCTION AS 10-100% CONTINUOUS DIMMING AND MANUAL O <br /> ON/OFF CONTROL PER THE 2016 CALIFORNIA BUILDING ENERGY <br /> EFFICIENCY STANDARDS FOR NON-RESIDENTIAL BUILDINGS, <br /> SECTION 130.1. <br /> DD. OCCUPANCY SENSORS AS SHOWN IN THESE PLANS IN OFFICES, 4ZI < J <br /> MULTI-PURPOSE,AND CONFERENCE ROOMS ARE TO BE u <br /> VACANCY SENSORS(MANUAL ON/AUTO OFF ONLY)AS DEFINED ( 1 <br /> IN THE 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY v <br /> STANDARDS FOR NON-RESIDENTIAL BUILDINGS,SECTION 100.1 .. <br /> AND AS REQUIRED IN SECTION 130.1. <br /> 10C >- <br /> EE. ALL LIGHT FIXTURES ARE TO BE PROVIDED WITH SHUT-OFF <br /> CONTROLS PER THE 2016 CALIFORNIA BUILDING ENERGY Q <br /> EFFICIENCY STANDARDS FOR NON-RESIDENTIAL BUILDINGS, <br /> SECTION 130.1(c). LIGHTS WILL COMPLY WITH THESE LL <br /> REQUIREMENTS VIA EITHER OCCUPANCY SENSOR CONTROL,OR <br /> THE EXISTING BMS CONTROLLING LIGHTING CONTACTORS.SEE <br /> SHEET E601 FOR THE EXISTING/NEW CONTACTOR CONTROL Q <br /> SCHEDULE.BMS CONTROLLED LIGHTING SHALL BE PROVIDED <br /> WITH LOCAL MANUAL OVERRIDE SWITCH THAT ALLOWS THE <br /> ASSOCIATED LIGHTS TO REMAIN ON FOR NO MORE THAN TWO <br /> HOURS AFTER THE OVERRIDE IS INITIATED. W <br /> W <br /> rJ <br /> V <br /> Z <br /> C) <br /> C) <br /> 00 <br /> N <br /> Project Number T-0738 <br /> Config: LL <br /> Drawn By E.VALLE <br /> Checked By B.HUN T <br /> CONSULTANT QUALITY ASSURANCE REVIEW ELECTRICAL COVER <br /> DOCUMENTS REVIEWED BY:BILL CRABB, P.E. SHEET <br /> REVIEWERS PHONE:208-493-0004 <br /> DATE REVIEWED:01114/2019 <br /> MODEL QUALITY REVIEWED BY:EASTON BOECK <br /> REVIEWERS PHONE:208-288-2181 <br /> DATE REVIEWED:01116/2019 <br /> E001 <br /> 1/17/2019 11:40:42 AM <br />