My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br /> A. TRACK LIGHTING SYSTEM DESCRIPTION: <br /> TRACK LIGHTING SYSTEM IS OWNER FURNISHED SINGLE CIRCUIT <br /> TRACK.TRACK LIGHTING LAYOUT SHOWN ON THIS PLAN <br /> INDICATES THE LOCATION AND CIRCUITRY OF THE TRACK AND <br /> TYPE OF CONNECTORS TO USE AT EACH INTERSECTION.TRACK <br /> 1 2 3 4 5SYSTEM IS MADE UP OF 2,4,6,8&12 FOOT SECTIONS OF TRACK. <br /> B. TARGET® <br /> TRACK INSTALLATION REQUIREMENTS: <br /> INSTALL TRACK ON CEILING GRID SYSTEM UTILIZING T-GRID <br /> SYSTEMS CLIPS PER MANUFACTURER'S INSTALLATION 1000 NICOLLET MALL <br /> REQUIREMENTS. BREAK OR REROUTE TRACKS AROUND MINNEAPOLIS, MN 55403 <br /> EXISTING MECHANICAL DIFFUSERS, LIGHTS,SKYLIGHTS, <br /> COLUMNS AND ANY OTHER EQUIPMENT IN LAY-IN CEILING. <br /> C. TRACK CONNECTOR INSTALLATION REQUIREMENTS: <br /> J TRACK CONNECTORS SHOWN ON THIS PLAN ONLY INDICATE THE <br /> PLAN LOCATION AND TYPE OF CONNECTORS TO USE(type"L","T", <br /> X",etc...). REFER TO TRACK INSTALLATION INSTRUCTIONS TO <br /> DETERMINE THE CORRECT CONNECTOR TO BE INSTALLED BASED <br /> ON MANUFACTURER'S CONNECTION DETAILS TO DETERMINE <br /> WHICH FITTING WILL PROVIDE THE CORRECT POLARITY.THE TOP <br /> VIEW DETAILS SHOW POLARITY ARROWS WHICH INDICATE WHAT <br /> IHI IH 1`1 tEt:1 SIDE OF THE TRACK IS"HOT"AND CAN BE USED TO QUICKLY DC ENGINEERING <br /> - _ ❑ DETERMINE THE ORIENTATION OF THE TRACK AND THE FITTING <br /> AS VIEWED FROM ABOVE.MODIFY WIRING TERMINATIONS INSIDE Careful listening. Dynamic solutions. <br /> CONNECTOR IF NECESSARY TO ACHIEVE CORRECT POLARITY. <br /> www.dcengineering.net <br /> D. TRACK SYSTEMS WIRING REQUIREMENTS: Phone:208.288.2181 Project:1 8TAR1 7 <br /> TERMINATIONS FOR TRACK CIRCUIT FEEDS ARE SIZED FOR A <br /> - _ _ MAXIMUM OF#12 AWG CONDUCTORS. PROVIDE#12 PIGTAIL <br /> BETWEEN HOMERUN CONDUCTORS AND TRACK TERMINALS. <br /> TEST FOR CORRECT POLARITY THROUGHOUT TRACK SYSTEMS <br /> u H BY ENGERGIZING A TRACK HEAD IN EACH TRACK SECTION. <br /> E. INSTALLATION AND AIMIN F TRACK HEAD <br /> GO :C S <br /> INSTALL OWNER FURNISHED TRACK HEADS IN LOCATIONS <br /> SHOWN ON PLAN.AIM ALL TRACK HEADS IN THE GENERAL <br /> DIRECTION OF STORE FIXTURES AND DISPLAYS PER TARGET <br /> PROVIDED PLACEMENT GUIDE. PLACEMENT GUIDE IS TO SHOW <br /> 0 TRACK HEAD TYPE(FLOOD OR SPOT)AND QUANTITY OF HEADS <br /> KLP-11 <br /> REQUIRED TO ILLUMINATE THE FIXTURE OR DISPLAY.ALL TRACK <br /> rid HEADS SHOULD BE AIMED AT A STORE FIXTURE OR DISPLAY, <br /> I I 25 LP-1 AVOID AIMING TRACK HEADS IN THE DIRECTION OF BULK HEADS, <br /> LJ <br /> T2 4 <br /> 1 RR T2-12 R R R R T2-1 352 <br /> R R R R R R R R R R R R R R R R 2 - 27 FLOORS AND THE DIRECTION OF THE MAIN AISLES. <br /> - <br /> R 25 Y Y Y y 25 y�y y�y yy� J J F. CIRCUIT BREAKER POWERING TRACK LIGHTING IS USED AS A <br /> R AA T2-12 T2-12 T2-12 T2-12 T212 T2-12 T2-12 T2-8 CURRENT LIMITING DEVICE PER NEC EXCEPTION 220.43(B). <br /> R R R R T2 8 _ R R R R 25 25 25 R R R 25 - 25 R R R 25 R R 25 R R 25 <br /> 25 652 G. STRAIGHTLINE CONNECTORS ARE NOT SHOWN ON THIS PLAN <br /> T212 FOR CLARITY. ELECTRICAL CONTRACTOR IS TO ASSUME A <br /> 1 R TYP T212 STRAIGHTLINE CONNECTOR WILL BE INSTALLED WHEN <br /> 27 CONNECTING 2 PIECES OF TRACK ON THE SAME CIRCUIT <br /> R R 0 TOGETHER WHEN THERE IS NO INTERSECTING TRACK. <br /> R> F IF iH <br /> H. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. Date NO. Description <br /> T2-12 01/17/2019 PERMIT SET <br /> � 1 TRACK CONNECTOR LEGEND <br /> R653 4T22 <br /> ❑ JUNO T24 WH SERIES"L"ADJUSTABLE CONNECTOR.JOINS TWO <br /> [, R TYP G L TRACK SECTIONS TO MAKE 90 DEGREE ANGLE. <br /> ❑ R R T2-4 - JUNO T25 WH SERIES"T"CONNECTOR.JOINS THREE TRACK <br /> R 11 R ❑ SECTIONS TOGETHER.T25R SERIES IS DESIGNED FOR USE IN <br /> REVERSE POLARITY ORIENTATION. <br /> 177 TTr� <br /> T2-8 R <br /> R 11 � JUNO T26 WH SERIES"X"CONNECTOR.JOINS FOUR TRACK <br /> R <br /> T2-12 T2-12 T2-8TR SECTIONS TOGETHER AT 90 DEGREE ANGLES. <br /> T2-12 11 11 11 T2-12 <br /> JUNO T36 WH SERIES T-BAR END FEED. FEEDS SURFACE <br /> 1 -El27 ❑ FROM ABOVE WHEN T BARS DIRECTLY ABOVE TRACK.T 6R CK <br /> ❑L ❑L r T <br /> R R R -R R R R R SERIES DESIGNED FOR USE IN REVERSE POLARITY <br /> R ORIENTATION. <br /> T2-12 T212 <br /> - =11 11 R � JUNO T35WH SERIES ADJUSTABLE JOINER FEED JOINS 2 TRACK <br /> SECTION TO MAKE 90-DEGREE ANGLE OR STRAIGHT RUN. <br /> R <br /> L R T212 - ❑ R R R R R R R R ❑ SEE 3/E151 - <br /> 1 777 FOR HOMERUN 652 T2-12 6 TRACK HEAD LEGEND <br /> R> T2-12 T2 12 T2-8 TYP 27 <br /> ❑ R� 11 11 11 J _ SEE LIGHTING FIXTURE SCHEDULE FOR SPECIFICATIONS <br /> R R 107 28 <br /> AND TOTAL QUANTITIES <br /> R 11 R SYMBOL TYPE <br /> _7� R IE <br /> T2-4 TYPE T2H1 <br /> 11 R SPOT DISTRIBUTION <br /> 50 TRIANGULAR SYMBOL <br /> T2 12 R ❑ T212 T 712 TYP MOUNTED TO WHITE TRACK <br /> [j I 1 27 F L L � TYPE T2H2 <br /> R ❑ ❑ <br /> it <br /> FLOOD DISTRIBUTION <br /> LJ I R R R R <br /> RECTANGULAR SYMBOL <br /> R 1 R MOUNTED TO WHITE TRACK <br /> � R R - R R 7 KEYNOTES <br /> R - <br /> R7. LH1 -El <br /> �, T2 12 T2-12 652 - R T2712 _ # DESCRIPTION <br /> R RLl co <br /> 27 TYP C 87 PROVIDE CONNECTION TO NEAREST EXISTING 277V VALANCE <br /> T2-12 EL - LIGHTING CIRCUIT TO FEED NEW RING LIGHTS. <br /> 1 - - 107 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING UNLESS <br /> R T2-12 R R R T2-12 R R R R R R R R T2-12 T2-12 R R T2-12 R R R R T2-12 R R T2-12 R R R-�R7T2-12 T2-12 R RR T2-12 R�R7 T2-8 LP-1 _ _ NOTED OTHERWISE. <br /> R 29 �y y 29 � �29 29 29 29 29 ���� 29 29 29 � 29 29 R - R - 352 EXISTING HOMERUN LOCATED ABOVE CEILING/IN JOIST SPACE <br /> R Lz� SHOWN FOR REFERENCE. PROVIDE CONNECTION TO <br /> R R R R R R R R R R R R R R R R R R R R R R R RR T2-8 R R T2-8 NEW/RELOCATED DEVICE/LIGHT FIXTURE. <br /> T212 7 7 650 INSTALL OWNER FURNISHED TRACK SYSTEM. TRACK IS MADE UP <br /> 1 - - - - OF 2,4,6,8,&12 FOOT SECTIONS. <br /> R o R T 512 G' 652 TYPICAL TRACK HEAD SPOT LIGHT(T2H1)INDIVIDUAL TRACK HEAD <br /> R R _ R II� CALLOUTS ARE NOT SHOWN. USE SYMBOL INDICATION TO <br /> R R DETERMINE IF TRACK HEAD IS SPOT OR FLOOD. <br /> R T2-8 R R T2-8 653 TYPICAL TRACK HEAD FLOOD LIGHT(T2H2)INDIVIDUAL TRACK �� ' G�9 <br /> R 7 7 HEAD CALLOUTS ARE NOT SHOWN. USE SYMBOL INDICATION TO <br /> R R R DETERMINE IF TRACK HEAD IS SPOT OR FLOOD. w Z m <br /> R�-i T2-12 - _ R R _ 675 RING LED LIGHT AT BEAUTY ALLEY. INSTALL OWNER FURNISHED Cr 181 <br /> 1 R R RING LIGHTS SUSPENDED FROM BUILDING STRUCTURE BY * 3 <br /> _ RT2-6 - SEE 2/E124 AIRCRAFT CABLES PER MANUFACTURER INSTALLATION �c �, P <br /> T2-12 T2 6 �FCTR�OP �� <br /> R R 7 T2-12 7 FOR HOMERUN REQUIREMENTS.MOUNT BOTTOM OF RING FIXTURE AS FOLLOWS: 9TF OQ' <br /> R R ❑ 0 5 E L 7 ❑Z RP8=11'-6"AFF OF CAL\F <br /> R R - RP12= 12'6"AFF <br /> R b R - <br /> J RP8=11'-6"AFF <br /> R - R R R 107 <br /> 1/17/2019 <br /> T2-12 LL B <br /> 1 T2-12 <br /> 5 <br /> O R <br /> R C) <br /> ir R M <br /> LL R Ln <br /> R 3 PERSONAL CARE LIGHTING PLAN <br /> �i <br /> J , E124 SCALE: 1/8" = V-0" <br /> T2-112 <br /> R � - T2-12 <br /> 5 z <br /> R / <br /> 1=1 LEI R>i O <br /> RR 1E1 L <br /> LL <br /> T2-12 <br /> R� ^ 5 Q J <br /> 1 V ALJ <br /> o i RD�,� Q <br /> R H �, ❑ � _ U <br /> R R R b R �.0 T2-12 D <br /> 5 <br /> -,J_ F=A - - <br /> T2-12 R <br /> R R 12 R T2-12 R>' T2-4 RRRRRR RRRRRRRR RRRRRRRR RRRRRR RRR F ^RRRRRRR R R R R T24 T28 T212 T28 T2I12 T24 650 T2-12 <br /> R 12 R 1 5 LP-6 7 7 7 T 7 7 �T TYP 7 U <br /> R \ R � yyyyyyyy YYY= \ yyyyyyyyyy y y y y 352 <br /> R� T2-12 T2-12 T2-12 T2-12 T2-12 T2-12 T2-12 T2-12 T2-12 T2-12 T2 8 J J 5 <br /> Y Y R>i 3 3 3 3 3 3 3 3 3 3 3 652 T2-12 RP12 T212 <br /> n r_ Q <br /> u R R R S T 1-8 352 J J TYP 7 � HL-3/38 7 8�7 675 <br /> 107 R - I � T/ Y P <br /> R <br /> 3/4"C-2#10,1#10G L12 J °O UJ <br /> 12 LP 6 352 N UJ <br /> 0 1I k <br /> N J <br /> RP8 �11 <br /> HL-3/38 <br /> T2-12 <br /> 12 R 5'-03/4" T-4" Z <br /> RP8 <br /> R HL-3/38 T2-12 \-2'-3 1/4" T2-12 Q <br /> 7 7 O <br /> Ll ILI <br /> 13 <br /> C <br /> T2 12 T212 T2-12 <br /> 12 7 11 7 <br /> R <br /> Project Number T-0738 <br /> R 3/4"C #10,1#10G <br /> T2-12� T2-4 <br /> T2-2 L 7 7 Z T2-2 Config: LL <br /> ❑ ❑ <br /> - 7 7 <br /> J LP-6 Drawn By E.VALLE <br /> T122 107 7 y B.HUNT <br /> Checked B <br /> R B <br /> I I <br /> R <br /> A & ATRACK <br /> LIGHTING PLAN <br /> A&A TRACK LIGHTING PLAN 2 BEAUTY BLOWOUT LIGHTING PLAN <br /> 7E I <br /> E124 SCALE: 1/8" = V-0" <br /> E124 SCALE: 1/8"= 1 -0 <br /> E124 <br /> PLAN NORTH <br /> 1/17/2019 11:41:05 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.