GENERAL NOTES
<br /> A. INSTALL OWNER FURNISHED POWER POLE(OFME E1)AND
<br /> MANUFACTURED WIRING SYSTEM CABLE FROM J-BOX TO POWER
<br /> POLES.
<br /> B. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY.REFER TO
<br /> OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT.
<br /> C. REFER TO 7/E531 AND 8/E531 FOR TYPICAL POWER POLE TARGET®
<br /> INSTALLATION.
<br /> D. REFER TO DETAILS 9,10,11,12,13,16,17,18&19/E511 FOR CONDUIT 1000 NICOLLET MALL
<br /> SUPPORTS AT ROOF STRUCTURE.REFER ALSO TO MINNEAPOLIS, MN 55403
<br /> SPECIFICATIONS.
<br /> E. REFER TO DETAILS 18&19/E511 FOR TYPE MC CABLE SUPPORT
<br /> FROM STRUCTURE.
<br /> F. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING
<br /> SYSTEM.REFER TO PRE MANUFACTURES INSTALLATION
<br /> DRAWINGS FOR INSTALLATION REQUIREMENTS.
<br /> G. EXISTING JUNCTION BOXES,CIRCUIT NUMBERS AND HOMERUNS
<br /> SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM
<br /> EXISTING PLANS.VERIFY EXACT CONDITIONS AT SITE. DIC ENGINEERING
<br /> H. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. Careful listening. Dynamic solutions.
<br /> www.dcengineering.net
<br /> KEYNOTES Phone:208.288.2181 Project:1 8TAR1 7
<br /> # DESCRIPTION
<br /> 352 EXISTING HOMERUN LOCATED ABOVE CEILING/IN JOIST SPACE
<br /> SHOWN FOR REFERENCE. PROVIDE CONNECTION TO
<br /> NEW/RELOCATED DEVICE/LIGHT FIXTURE.
<br /> 601 INSTALL PRE MANUFACTURED POWER DISTRIBUTION BOX ABOVE
<br /> ACCESSIBLE CEILING.
<br /> 602 INSTALL PRE MANUFACTURED MAINRUN CABLE FROM POWER
<br /> DISTRIBUTION BOX TO PANELBOARD.
<br /> 603 INSTALL PRE MANUFACTURED EXTENDER CABLE FROM POWER
<br /> DISTRIBUTION BOX TO SPLITTER MOUNTED IN BASE DECK OF
<br /> FIXTURE.
<br /> 604 ROUTE PRE MANUFACTURED EXTENDER CABLE INSIDE OF WALL
<br /> TO THE BASE DECK OF THE FIXTURE.
<br /> 605 INSTALL OWNER FURNISHED MULTI-OUTLET ASSEMBLY KIT
<br /> PROVIDED WITH ALTERNATING CIRCUITS AND 20 AMP SIMPLEX
<br /> RECEPTACLES SPACED 12"ON CENTER.MOUNT MULTI-OUTLET
<br /> ASSEMBLY ON TOP RAIL OF GONDOLA. PROVIDE FENDER WASHER
<br /> SPACERS UNDERNEATH MULTI-OUTLET ASSEMBLY SO RACEWAY
<br /> IS INSTALLED LEVEL ON TOP RAIL OF GONDOLA. INSTALL
<br /> MULTI-OUTLET ASSEMBLY KIT THE ENTIRE LENGTH OF THE
<br /> GONDOLA RUN,STOPPING A MINIMUM OF 12"FROM EACH END OF
<br /> THE GONDOLAS RUN. INSTALL MULTI-OUTLET ASSEMBLY KIT PER
<br /> MANUFACTURER'S REQUIREMENTS. REFER TO DETAIL 17/E531.
<br /> 607 MOUNT RECEPTACLE HORIZONTALLY IN PEG BOARD. REFER TO
<br /> DETAIL 18/E531. Date No. Description
<br /> 608 PROVIDE RECEPTACLE WITH 6'RELOC WHIP CORD LOOSE IN BASE
<br /> DECK OF GONDOLA.COIL UP RELOC CORD FOR FUTURE USE. 01/17/2019 PERMIT SET
<br /> 611 MAKE CONNECTIONS TO EXISTING PRE MANUFACTURED POWER
<br /> DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. UTILIZE
<br /> EXISTING PRE MANUFACTURED MAINRUN CABLE CIRCUITS.
<br /> 613 ROUTE WIRING IN 1/2"(OR AS NOTED)FLEX CONDUIT AND#10
<br /> WIRE FROM EXISTING CIRCUIT LOCATED ABOVE ACCESSIBLE
<br /> CEILING TO PRE-MANUFACTURED WIRING SPLITTER LOCATED AT
<br /> 5 6 POWER POLE. INSTALL PRE MANUFACTURED WIRING FROM
<br /> SPLITTER DOWN THRU POWER POLE THRU GONDOLA.CONCEAL
<br /> WITHIN STORE FIXTURES.SIMILAR TO DETAIL 7/E541.
<br /> 625 OWNER FURNISHED VALANCE LIGHTS FIXTURE TYPE VL3
<br /> INSTALLED ON FREE STANDING BEAUTY GONDOLAS ARE
<br /> PROVIDED WITH CORD AND PLUG ARE SHOWN ON OWNERS
<br /> STORE FIXTURE PLAN AND ARE INSTALLED BY ELECTRICAL
<br /> CONTRACTOR. ELECTRICAL CONTRACTOR SHALL CONNECT PLUG
<br /> AND CORD ON EACH GONDOLA RUN OF VALANCE LIGHTS TO
<br /> ENERGIZE DAISY CHAINED VALANCE LIGHTS DOWNSTREAM.
<br /> VALANCE LIGHTS PLUG INTO POWER STRIP INSTALLED ON TOP OF
<br /> GONDOLA.CONNECT CORD AND PLUG TO VALANCE LIGHT PER
<br /> FOCUS LIGHTING SHOP DRAWINGS. CONTACT FOCUS LIGHTING
<br /> LP-6/15 O DIRECTLY WHEN CORD&PLUG IS NOT FOUND ON SITE, REFER TO
<br /> LIGHT FIXTURE SCHEDULE NOTES FOR FOCUS LIGHTING
<br /> 60" 608 60„ CONTACT INFORMATION.
<br /> 60" zQ LP-6/34 LP-6/10
<br /> LP-6/3260" 605 605 605 605
<br /> LP-6/12
<br /> 60" 60"
<br /> 60" LP-6/34 LP-6/10
<br /> 605 LP-6/32 608 625
<br /> 60"
<br /> LP-6/15 (ax1) LP-6/12 625 625 625
<br /> 605
<br /> 60
<br /> 60" 60"
<br /> 60" LP-6/34 LP-6/10
<br /> LP-6/32 60"
<br /> 625 607 LP-6/12
<br /> 625 625 TYP O
<br /> 60" 60"
<br /> 60" LP-6/34 LP-6/10
<br /> LP-6/32 601, 60„ 60" a a a a
<br /> =:�) LP-6/41 608 LP-6/4 LP-6/12
<br /> 60" 60 -
<br /> LP 6/42 LP-6/6
<br /> 60" LP-6/39 60"
<br /> I 60.. LP-6/34 I LP-6/10
<br /> LP-6/32 60„ 608 60„ 60"
<br /> LP-6/41 LP-6/42 p LP-6/4 LP-6/12
<br /> 60" 607 (ax1) 60"
<br /> 607 p,OF /
<br /> 60" LP-(/39 TYP LP 6/6 60" TYP Q G
<br /> 60" EiQ LP-6/34 LP-6/10
<br /> LP-6/32 � 60" 60„ 607 60„ w =P z m
<br /> LP-6/41 LP-6/4 TYP LP-6/12 81 �o
<br /> 60" * 3
<br /> 60"
<br /> 60"LP 6/34 LP-6/39 608 LP 6/6 LP-6/1060 q F�ECTF �oQ��P
<br /> 60"
<br /> OF CAS
<br /> LP-6/32LP-6/40
<br /> 60" 60" 60" LP-6 352
<br /> LP-6/31,33 LP-6/35,37 LP-6/41 608 LP-6/4 Qo LP-6/12 LP-6/19,21 LP-6/28,30 LP-6/18,20 LP-6/14,16
<br /> 60
<br /> LP 6/40 60" 1 N (ax1 14,16,18,20,19,21,23,25,28,30
<br /> LP-6/39 LP-6/6
<br /> ax1 (ax1) 613 1/17/2019
<br /> 613
<br /> 613
<br /> LP-6602 601 603 603 613 O
<br /> 27,29,31,33,32,334,35,37,36,38 TYP TYP 611
<br /> LP-6/27,29
<br /> #10 ,601
<br /> 605 LP-6 605 605
<br /> 613
<br /> #10 4,6,10,12,15,39,40,41,42 605
<br /> LP-6/36,38 602' LP 6/23,25 LP-6/23,25 LP 6/23,25
<br /> LP-6/36,38
<br /> oe PQPQ z
<br /> B LU
<br /> 604 604 604 604
<br /> 605 O
<br /> IMAGE SCREEN LL
<br /> 1 BEAUTY BLOWOUT & PERSONAL CARE POWER & SYSTEMS Q J
<br /> E385 SCALE: 1/4"= 1'-0"
<br /> U �
<br /> U
<br /> UQ
<br /> Q �
<br /> � o
<br /> UJ
<br /> UJ
<br /> J
<br /> CD
<br /> Q
<br /> z
<br /> 0
<br /> 0
<br /> 00
<br /> 1: N
<br /> Project Number T-0738
<br /> Config: LL
<br /> Drawn By G.F 1 KRAT
<br /> Checked By B.H U NT
<br /> BEAUTY &
<br /> PERSONAL CARE
<br /> POWER & SYSTEMS
<br /> PLAN
<br /> E385
<br /> PLAN NORTH
<br /> 1/17/2019 11:41:47 AM
<br />
|