Material Safety Data Sheet 'Page 3 of 8
<br /> L %W.)
<br /> OSHA Classification (29 CFR 1910.1200): Combustible liquid.
<br /> NFPA RATINGS: Health: 0 Flammability: 2 Reactivity: t)
<br /> 1 FLAMMABLE PROPERTIES:
<br /> Flashpoint: (Pensky-Martens Closed Cup) 52 °C (125 °F) (Min)
<br /> Autoignition: 257 °C (494 'F)
<br /> Flammability (Explosive) Limits (% by volume in air): Lower. 0.6 Upper: 4.7
<br /> EXTINGUISHING MEDIA: Dry Chemical, CO2, AFFF Foam or alcohol resistant foam.
<br /> PROTECTION OF FIRE FIGHTERS:
<br /> Fire Fighting Instructions: For Fres involving this material, do not enter any enclosed or confined fre space
<br /> without proper protective equipment, including self-contained breathing apparatus.
<br /> Combustion Products: Highly dependent on combustion conditions_ A complex mixture of airborne solids,
<br /> liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be
<br /> evolved when this material undercloes combustion.
<br /> SECTION 6 ACCIDENTAL RELEASE MEASURES
<br /> Protective Measures: Eliminate all sources of ignition in the vicinity of the spill or released vapor. If this material
<br /> is released into the work area, evacuate the area immediately. Monitor area with combustible gas indicator.
<br /> Spill Management: Stop the source of the release if you can do it without risk. Contain release to prevent further
<br /> contamination of soil, surface water or groundwater. Clean up spill as soon as possible, observing precautions in
<br /> L Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent
<br /> materials or pumping. All equipment used when handling the product must be grounded. A vapor suppressing
<br /> foam may be used to reduce vapors. Use clean non-sparking tools to collect absorbed material..Where feasible
<br /> and appropriate, remove contaminated soil. Place contaminated materials in disposable containers and dispose
<br /> of in a manner consistent with applicable regulations.
<br /> Reporting: Report spills to local authorities and/or the U.S. Coast Guard's National Response Center at(800) .
<br /> 424-8802 as appropriate or required.
<br /> SECTION 7 HANDLING AND STORAGE
<br /> Precautionary Measures: Liquid evaporates and forms vapor(fumes)which can catch fire and burn with
<br /> explosive force. Invisible vapor spreads easily and can be set on Fre by many sources such as pilot lights,
<br /> welding equipment, and electrical motors and switches. Fire hazard is greater as liquid temperature rises above
<br /> 85F. Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Do not breathe vapor or fumes. Do not
<br /> L breathe mist. Wash thoroughly after handling. Keep out of the reach of children.
<br /> Unusual Handling Hazards: WARNING! Do not use as portable heater or appliance fuel. Toxic fumes may
<br /> accumulate and cause death.
<br /> General Handling Information: Avoid contaminating soil or releasing this material into sewage and drainage
<br /> I L systems and bodies of water.
<br /> Static Hazard: Electrostatic charge may accumulate and create a hazardous condition when handling this
<br /> material. To minimize this hazard, bonding and grounding may necessary l
<br /> Lsufficient. Review all operations ary but may not, by themselves be
<br /> p ns which have the potential of generatingand accumulating
<br /> and/or a flammable atmosphere (including tank and container filling, slash filling tank clle n cleaning,
<br /> gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating
<br /> procedures. For more information, refer to OSHA Standard 29 CFR 1910.106, 'Flammable and Combustible
<br /> L Liquids', National Fire Protection Association (NFPA 77, 'Recommended Practice on Static Electrici
<br /> ty% and/or
<br /> American Petroleum institute (API) Recommended Practice 2003, 'Protection Against Ignitions Arising out of the
<br /> Static, Lightning, and Stray Currents'.
<br /> General Storage Information: DO NOT USE OR STORE near meat, sparks flames, or hot surfaces . USE AND
<br /> STORE ONLY IN WELL VENTILATED AREA. Keep container closed when not in use.
<br /> Container Warnings: Container is not designed to contain pressure. Do not use pressure to empty container or-it
<br /> Lmay rupture with explosive.force. Empty containers retain product residue (solid, liquid, and/or vapor) and 'can be
<br /> dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame,
<br /> sparks, static electricity, or Other sources of ignition. They may explode and cause injury or death. Empty
<br /> containers should be completely drained, properly closed, and promptly returned to a drum reconditioner or
<br /> disposed of properly.
<br /> https://www.cbest.chevron.c
<br /> om/msdsServer/controller? _
<br /> module com.chevron.lubes.msds.... 11/15/2004 �I
<br />
|