Laserfiche WebLink
Material Safety Data Sheet 'Page 3 of 8 <br /> L %W.) <br /> OSHA Classification (29 CFR 1910.1200): Combustible liquid. <br /> NFPA RATINGS: Health: 0 Flammability: 2 Reactivity: t) <br /> 1 FLAMMABLE PROPERTIES: <br /> Flashpoint: (Pensky-Martens Closed Cup) 52 °C (125 °F) (Min) <br /> Autoignition: 257 °C (494 'F) <br /> Flammability (Explosive) Limits (% by volume in air): Lower. 0.6 Upper: 4.7 <br /> EXTINGUISHING MEDIA: Dry Chemical, CO2, AFFF Foam or alcohol resistant foam. <br /> PROTECTION OF FIRE FIGHTERS: <br /> Fire Fighting Instructions: For Fres involving this material, do not enter any enclosed or confined fre space <br /> without proper protective equipment, including self-contained breathing apparatus. <br /> Combustion Products: Highly dependent on combustion conditions_ A complex mixture of airborne solids, <br /> liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be <br /> evolved when this material undercloes combustion. <br /> SECTION 6 ACCIDENTAL RELEASE MEASURES <br /> Protective Measures: Eliminate all sources of ignition in the vicinity of the spill or released vapor. If this material <br /> is released into the work area, evacuate the area immediately. Monitor area with combustible gas indicator. <br /> Spill Management: Stop the source of the release if you can do it without risk. Contain release to prevent further <br /> contamination of soil, surface water or groundwater. Clean up spill as soon as possible, observing precautions in <br /> L Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent <br /> materials or pumping. All equipment used when handling the product must be grounded. A vapor suppressing <br /> foam may be used to reduce vapors. Use clean non-sparking tools to collect absorbed material..Where feasible <br /> and appropriate, remove contaminated soil. Place contaminated materials in disposable containers and dispose <br /> of in a manner consistent with applicable regulations. <br /> Reporting: Report spills to local authorities and/or the U.S. Coast Guard's National Response Center at(800) . <br /> 424-8802 as appropriate or required. <br /> SECTION 7 HANDLING AND STORAGE <br /> Precautionary Measures: Liquid evaporates and forms vapor(fumes)which can catch fire and burn with <br /> explosive force. Invisible vapor spreads easily and can be set on Fre by many sources such as pilot lights, <br /> welding equipment, and electrical motors and switches. Fire hazard is greater as liquid temperature rises above <br /> 85F. Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Do not breathe vapor or fumes. Do not <br /> L breathe mist. Wash thoroughly after handling. Keep out of the reach of children. <br /> Unusual Handling Hazards: WARNING! Do not use as portable heater or appliance fuel. Toxic fumes may <br /> accumulate and cause death. <br /> General Handling Information: Avoid contaminating soil or releasing this material into sewage and drainage <br /> I L systems and bodies of water. <br /> Static Hazard: Electrostatic charge may accumulate and create a hazardous condition when handling this <br /> material. To minimize this hazard, bonding and grounding may necessary l <br /> Lsufficient. Review all operations ary but may not, by themselves be <br /> p ns which have the potential of generatingand accumulating <br /> and/or a flammable atmosphere (including tank and container filling, slash filling tank clle n cleaning, <br /> gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating <br /> procedures. For more information, refer to OSHA Standard 29 CFR 1910.106, 'Flammable and Combustible <br /> L Liquids', National Fire Protection Association (NFPA 77, 'Recommended Practice on Static Electrici <br /> ty% and/or <br /> American Petroleum institute (API) Recommended Practice 2003, 'Protection Against Ignitions Arising out of the <br /> Static, Lightning, and Stray Currents'. <br /> General Storage Information: DO NOT USE OR STORE near meat, sparks flames, or hot surfaces . USE AND <br /> STORE ONLY IN WELL VENTILATED AREA. Keep container closed when not in use. <br /> Container Warnings: Container is not designed to contain pressure. Do not use pressure to empty container or-it <br /> Lmay rupture with explosive.force. Empty containers retain product residue (solid, liquid, and/or vapor) and 'can be <br /> dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, <br /> sparks, static electricity, or Other sources of ignition. They may explode and cause injury or death. Empty <br /> containers should be completely drained, properly closed, and promptly returned to a drum reconditioner or <br /> disposed of properly. <br /> https://www.cbest.chevron.c <br /> om/msdsServer/controller? _ <br /> module com.chevron.lubes.msds.... 11/15/2004 �I <br />