WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHANNEL
>
730
>
3500 - Local Oversight Program
>
PR0544199
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2019 11:46:35 PM
Creation date
2/27/2019 4:14:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0544199
PE
3528
FACILITY_ID
FA0014183
FACILITY_NAME
RAYMOND INVESTMENT CORPORATION
STREET_NUMBER
730
Direction
E
STREET_NAME
CHANNEL
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
02
SITE_LOCATION
730 E CHANNEL ST
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
283
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(MSDS: 731678) page 5 of 10 <br /> Do not enter confined spaces such as tanks or pits without following proper entry procedures such as ASTM <br /> 0-4276 and 29CFR 1910.146. The use of appropriate respiratory protection is advised when concentrations <br /> exceed any established exposure.limits (see Sections 2 and 8). <br /> Wash thoroughly after handling. Do not wear contaminated clothing or shoes. Keep contaminated clothing <br /> away from sources of ignition such as sparks or open flames. Use good.personal hygiene practices. <br /> High pressure injection of hydrocarbon fuels, hydraulic oils or greases under the skin may have serious <br /> consequences even though no symptoms or injury may be apparent. This can happen accidentally when using . <br /> high pressure equipment such as high pressure grease guns,fuel injection apparatus or from pinhole leaks in <br /> tubing of high pressure hydraulic oil equipment. <br /> "Empty'containers retain residue and may be dangerous. Do not pressurize,cut, weld, braze, solder, drill, <br /> grind, or expose such containers to heat, flame, sparks,or other sources of ignition. They may explode and <br /> cause injury or death. "Empty'drums should be completely drained, property bunged, and promptly shipped to <br /> the supplier ora drum.reconditioner. All containers should be disposed of in an environmentally safe <br /> manner and in accordance with governmental regulations. <br /> Before working on or in tanks which contain or have contained this material, refer to OSHA regulations,ANSI <br /> 249.1 and other references pertaining to cleaning, repairing,welding,or other contemplated operations. <br /> Storage: Keep containers) tightly closed. Use and store this material in cool, dry,well-ventilated <br /> areas away from heat,-direct sunlight, hot metal surfaces, and all sources of ignition. Post area "No <br /> Smoking or Open'Flame." Store only in approved containers. Keep away from any incompatible material (see <br /> Section 10). Protect container(s)against physical damage. Outdoor or detached storage is preferred. <br /> Indoor storage should meet OSHA standards and appropriate fire codes. <br /> Portable Containers: <br /> Static electricity may ignite gasoline vapors when-filling portable containers. To avoid static buildup do <br /> not use a nozzle lock open device. Use only approved containers for the storage of gasoline. Place the- <br /> (., container on the ground before filling. Keep the nozzle in contact with the container during filling. <br /> Do not fill any portable container in or on a vehicle or marine craft. <br /> B. EXPOSURE CONTROLSIPERSONAL PROTECTION <br /> Engineering controls: If current ventilation practices are not adequate to maintain airborne concentrations below <br /> the established exposure limits(see Section 2), additional engineering controls may be required. Where explosive <br /> mixtures may be present, electrical systems safe for such locations must be used (see appropriate electrical <br /> codes). <br /> Personal Protective Equipment(PPE): <br /> Respiratory: A NIOSH certified air purifying respirator with an organic vapor cartridge may <br /> be used under conditions where airborne concentrations are expected to exceed exposure <br /> limits (see Section 2). <br /> F Protection provided by air purifying respirators is limited (see manufacturer's respirator <br /> i selection guide). Use a NIOSH approved self-contained breathing apparatus (SCBA)or <br /> equivalent operated in a pressure demand or other positive pressure mode if there is <br /> potential for an uncontrolled release,exposure levels are not known,or any other <br /> circumstances where air purifying respirators may not provide adequate protection. <br /> A-respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI 288.2 <br /> requirements must be followed whenever workplace conditions warrant a respirator's use. <br /> Skin: The use of gloves impervious to the specific material handled is advised to prevent skin <br /> contact, possible irritation,and skin damage. Examples of approved materials are . <br /> nitrile, or Viton®(see glove manufacturer literature for information on permeability). <br />
The URL can be used to link to this page
Your browser does not support the video tag.