AST SP001 ANNUAL INSPECTION <br /> Item Task Status <br /> 5.3.4 Solenoid valves Cycle power to valve and confirmed operation.(Electdcal r Yes r No F N/A <br /> solenoids can be verified by listening to the plunger opening <br /> and closing. If no audible confirmation,the valve should be <br /> inspected for the presence and operation of the plunger.)(enter <br /> manufacturer and model number in Comments if available <br /> 5.3.5 Fire and shear valves a. Manually cycle the valve and confirmed components are r Yes r No r NIA <br /> moving freely and that the valve handle or lever has clearance <br /> to allow valve to close completely.(enter manufacturer and <br /> model number in Comments if available) <br /> b.Valves must not be wired in open position. r Yes r No R N/A <br /> c. Make sure fusible element is in place and correctly r Yes r-No 171 N/A <br /> positioned. <br /> d.Be sure test pons are sealed with plug after testing is r Yes r No r N/A <br /> complete and no temporary test fixture or component remains <br /> connected to valve. <br /> Comments: <br /> 5.4 Interstitial leak detection Check condition of equipment,including: <br /> equipment • Make: ,Model: <br /> • The window is clean and clear in sight leak gauges. rYes r No r N/A <br /> • The wire connections of electronic gauges for tightness and r Yes r No r N/A <br /> corrosion. r Yes r No r N/A <br /> • Activate the test button,if applicable. <br /> 5.5 Spill containment boxes a.Confirmed SB is free of corrosion,damage,or wear that r Yes r No r N/A <br /> on fill pipe has compromised the ability of the unit to perform spill <br /> containment functions(enler manufacturer and model number <br /> in Comments if available) <br /> b.Confirmed connections to the AST are tight, and all bolts, r Yes r No r N/A <br /> nuts,washers are in good condition. <br /> c.Confirmed drain valves are operational. r Yes r No P N/A <br /> 5.6 Strainer a.Confirmed that the strainer is clean and in good condition. r Yes r No F NIA <br /> (enter manufacturer and model number in Comments if <br /> available) <br /> b.Confirmed strainer basket,cap,bolts and gasket seal are rYes r No r+NIA <br /> in good condition. <br /> 5.7 Filter a.Confirmed that the filter is in good condition and is within r Yes r No F N/A <br /> the manufacturers expected service life.Replace,if <br /> necessa .Make:,Model: <br /> b.Confirmed no leaks or decreased fuel flow. r Yes r No r N/A <br /> 5.8 Flame arrestors Inspected for proper operation per manufacturer's instructions r Yes r No r N/A <br /> and no corrosion or blockage of air passages.(enter <br /> manufacturer and model number in Comments if available) <br /> 5.9 Leak detector for Have been or were tested per manufacturers instructions and r Yes r No r N/A <br /> submersible pump systems authority having jurisdiction(AHJ)and verify leak detectors are <br /> suited and properly installed for above ground use. <br /> Make: ,Model: <br /> 5.10 Liquid level equipment a.Make: ,Model: <br /> b.Has equipment been tested to ensure proper operation? r-Yes r No 17 NIA <br /> c. Does equipment operate as required? r-Yes r No F N/A <br /> d.Does the equipment perform per manufacturers rYes r No F NIA <br /> Instructions? <br /> WO: 6703239 SEPIQv113ER2016 <br />