Laserfiche WebLink
AST SP001 ANNUAL INSPECTION <br /> Item Task Status <br /> 5.3.4 Solenoid valves Cycle power to valve and confirmed operation.(Electrical I—Yesr No F N/A <br /> solenoids can be verified by listening to the plunger opening <br /> and closing. If no audible confirmation,the valve should be <br /> inspected for the presence and operation of the plunger.)(enter <br /> manufacturer and model number in Comments if available <br /> 5.3.5 Fire and shear valves a. Manually cycle the valve and confirmed components are rYes r No r N/A <br /> moving freely and that the valve handle or lever has clearance <br /> to allow valve to close completely.(enter manufacturer and <br /> model number in Comments if available) <br /> b.Valves must not be wired in open position. r Yes r No r N/A <br /> c. Make sure fusible element is in place and correctly r Yes r No A N/A <br /> positioned. <br /> it. Be sure test ports are sealed with plug atter testing is r Yes r No r N/A j <br /> complete and no temporary test fixture or component remains <br /> connected to valve. <br /> Comments: <br /> 5.4 Interstitial leak detection Check condition of equipment,including: <br /> equipment • Make: ,Model: <br /> • The window is clean and clear in sight leak gauges. r Yes r No r N/A <br /> • The wire connections of electronic gauges for tightness and r Yes r No r N/A <br /> corrosion. r Yes r No r N/A <br /> • Activate the test button, if applicable. <br /> 5.5 Spill containment boxes a.Confirmed SB is free of corrosion,damage, or wear that r Yes r No r N/A <br /> on fill pipe has compromised the ability of the unit to perform spill <br /> containment functions(enter manufacturer and model number <br /> in Comments if available) <br /> b.Confirmed connections to the AST are tight,and all bolts, r Yes r No f✓N/A <br /> nuts,washers are in good condition. <br /> c.Confirmed drain valves are operational. r Yes r No A N/A <br /> 5.6 Strainer a.Confirmed that the strainer is clean and in good condition. r Yes r No r N/A <br /> (enter manufacturer and model number in Comments if <br /> available) <br /> b.Confirmed strainer basket,cep,bolts and gasket seal are r Yes r No r N/A <br /> in good condition. <br /> 5.7 Filter a.Confirmed that the fiher is in good condition and is within r Yes r No F N/A <br /> the manufacturers expected service life.Replace,if <br /> necessa .Make:,Model: <br /> b.Confirmed no leaks or decreased fuel flow. r Yes r No F N/A <br /> 5.8 Flame arrestors Inspected for proper operation per manufacturers instructions r Yes r Nor N/A <br /> and no corrosion or blockage of air passages.(enter <br /> manufacturer and model number in Comments if available <br /> 5.9 Leak detector for Have been or were tested per manufacturers instructions and r Yes r No F N/A <br /> submersible pump systems authority having judsdicfion(AHJ)and verify leak detectors are <br /> suited and properly installed for above ground use. <br /> Make: ,Model: <br /> 5.10 Liquid level equipment a.Make: ,Model: <br /> b. Has equipment been tested to ensure proper operation? r Yes r No r N/A <br /> c.Does equipment operate as required? r Yes r No r N/A <br /> d.Does the equipment perform per manufacturers r Yes r No r N/A <br /> instructions? <br /> WO: 6703239 SEPIEN®ER2016 <br />