Laserfiche WebLink
San Joaquin County DIRECTOR <br /> ' <br /> PqU 1.N. Linda Turkatte, REHS <br /> hyo Environmental Health Department f"' ASSISTANT DIRECTOR <br /> Q=" r 1868 E Hazelton Avenue Kasey Foley, REHS <br /> . . <br /> Stockton, California 95205 PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> �" • `�Q Jeff Carruesco, REHS, RDI <br /> FORS Website: www.sjcehd.com Rodney Estrada, REHS <br /> Phone: (209)468-3420 Willy Ng, REHS <br /> Fax: (209)464-0138 Muniappa Naidu, REHS <br /> March 13, 2017 <br /> Edward Araya C <br /> 12720 N Lower Sacramento Rd 0 no— Nor <br /> Lodi, CA 95242 <br /> RE: Well Pump Inspection <br /> Well Location: 12732 N Lower Sacramento Rd Permit#: SR0076553 Inspection Date: 03/01/2017 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above <br /> address and found the following issues at the time of the inspection. In order to protect the ground water <br /> supply and your water source from potential degradation, please take the associated corrective actions. <br /> ❑x Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Sea[) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code, Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑ Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑ Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> ❑ Other: <br /> If you have any questions please call Mike Escotto, Senior Registered Environmental Health <br /> Specialist, at (209) 468-3443 <br /> LRQdn Estrada, REHS <br /> Program Coordinator <br />