23100
>
2800 - Aboveground Petroleum Storage Program
>
PR0516434
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2019 4:10:39 PM
Creation date
2/28/2019 11:34:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516434
PE
2832
FACILITY_ID
FA0010206
FACILITY_NAME
VALLEY PACIFIC PETROLEUM
STREET_NUMBER
23100
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23906004
CURRENT_STATUS
01
SITE_LOCATION
23100 S KASSON RD
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Reg uirernerrts for Onritinued Service <br /> 2 , 000g Unleaded <br /> o The tank sidewall is only located approx . 9" from the 15, 000 gallon Diesel sidewall . The <br /> rninimum required spacing is calculated using various methods and regulations . Title 8 <br /> § 5590 ( b ) states the sum of the diameters divided by six is the minimum distance the <br /> tanks shall be spaced apart ( approx 28" ) . <br /> o An Emergency Venting device is required on the Annular Space . The spare 4" ports on <br /> the annular space may be adequate to provide this . <br /> o "Safe Filling Level' and "Gasoline" content labels need to be installed on all applicable <br /> portions of the tank . <br /> 15, 000g Diesel <br /> o The tank sidewall is only located approx . 9" from the 2, 000 gallon Diesel sidewall . T he <br /> minimum required spacing is calculated using various methods and regulations . Title 8 <br /> § 5590 ( b ) states the sum of the diameters divided by six is the minimum distance the <br /> tanks shall be spaced apart ( approx 28 " ) . <br /> o An Emergency Venting device is required on the Annular Space . The spare 4" ports on <br /> the annular space may be adequate to provide this . <br /> o "Safe Filling Level' and "Diesel' content labels need to be installed on all applicable <br /> portions of the tank . <br /> P 20,000g Diesel <br /> o An Emergency Venting device is required on the Annular Space . The spare 4" ports on <br /> the annular space may be adequate to provide this . <br /> o "Safe Filling Level' and "Diesel' content labels need to be installed on all applicable <br /> portions of the tank . <br /> Professional Opr aiorr <br /> The subject aboveground storage tank ( s ) at Valley Pacific Petroleum , 22888 Kasson Rd , Tracy, CA <br /> 95304 have been inspected using procedures found in STI SP -001 ( 5th Edition )• publication " Standard for <br /> the Inspection of Aboveground Storage Tanks " . <br /> It is the professional opinion of this firm that the tanks are in acceptable condition , and fit for <br /> continued service ( pending completion of the required repairs ) . <br /> This is not to be construed as an expressed or implied warranty of f uture performance . <br /> Should you have any questions or comments concerning this inspection report, please do not <br /> hesitate to contact the undersigned at 415 -997 ,, 8034 or via email at mitred@NWTLI . com . <br /> Michael Driggs <br /> rniked@NWTLI . com <br /> SP -001 Inspector ( 810125 ) <br />