Laserfiche WebLink
SAN -]OAQ U I N Environmental A t N E� artment <br /> COJ NITY <br /> a 3 / C <br /> tea . Gr' ftit15e55 4lrowc �1ere . <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name : Facility Phone: Date : <br /> VALLEY PACIFIC PETROLEUM (209 ) 948 -9412 February 11 , 2019 <br /> Facility Address : CERS ID: <br /> 23100 S KASSON RD , TRACY , CA 95376 10183315 <br /> Inspection Contact: Title: Phone: <br /> Ed Ward Risk & Regulatory Manager (209 ) 948-9412 <br /> Inspection Type: Program : <br /> ROUTINE INSPECTION - Operating Permit 12832 - ASTFAC 10 K - </= 100 K GAL CUMULATIVE <br /> Consent For: Consent Given By : <br /> 0 Inspection 0 Photos ❑ Samples I Ed Ward , Risk & Regulatory Manager <br /> CCR = California Code of Regulations HSC = Health and Safety Code CFR = Title 40 Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> Aboveground Petroleum Storage Act <br /> 101 HSC 25270 . 6(b) Failed to pay APSA program annual fees ❑ V ❑ R ❑ COS <br /> 102 HSC 25270 . 4 . 5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 ❑ V ❑ R ❑ COS <br /> 103 HSC 25270 . 6 (a) Failed to file HMBP or annual facility tank statement ❑ V ❑ R ❑ COS <br /> 104 HSC 25270 . 8 Failed to report spills or releases of 42 gallons (one barrel) or more ❑ V ❑ R ❑ COS <br /> 105 CFR 112A (b) (3) , 112 , 2 Failure to properly close tanks when making a claim of permanently closed ❑ V ❑ R ❑ COS <br /> 106 HSC 25404 . 1 . 2 Failed to submit a certification and written response within 30 days for minor violations ❑ V ❑ R ❑ COS <br /> 107 HSC 25270 . 2 (a) (4) Failure to prepare SPCC plan when facility no longer meets oil-filled electrical equipment exclusion ❑ V ❑ R ❑ COS <br /> 108 HSC 25270 . 4 . 5(a) Failure of conditionally exempt facility to conduct inspections or install secondary containment ❑ V ❑ R ❑ COS <br /> 109 HSC 25270 . 2 (o) ( 1 ) (C) Failure to have secondary containment and/or leak detection if TIUGA piping cannot be viewed ❑ V ❑ R ❑ COS <br /> ( iv) ( IIl) <br /> 110 HSC 25404(e) (4) Failed to report program data in the California Environmental Reporting System (CERS) ❑ V ❑ R ❑ COS <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112 . 3(d ) Failure to have a licensed PE properly review and certify the SPCC plan ❑ V ❑ R ❑ COS <br /> 202 CFR 112 . 3 (e) ( 1 ) Failed to maintain a copy of the Plan on site ❑ V ❑ R ❑ COS <br /> 203 CFR 112 . 3 Failure to implement the SPCC Plan ■ V ❑ R ❑ COS <br /> 204 CFR 112 . 3(g) Failure to prepare SPCC Plan when facility no longer meets Qualified Facility criteria ❑ V iiR ❑ COS <br /> 205 CFR 112 . 3 , 112 . 6 Failure to prepare SPCC Plan that meets all applicable requirements ❑ V ❑ R ❑ COS <br /> 206 CFR 112 . 3(d ) ( 1 ) Failure of owner to assure that the PE makes all required attestations in the Plan ❑ V ❑ R ❑ COS <br /> Amendment of SPCC Plan by Owners or Operators <br /> 301 CFR 112 . 5 (a) Failed to amend Plan as necessary ❑ V ❑ R ❑ COS <br /> 302 CFR 112 . 5 (b) Failed to review Plan once every five years and/or implement any resulting amendments ❑ V ❑ R ❑ COS <br /> 303 CFR 112 . 5 (c) Failed to have a PE certify technical amendments ❑ V ❑ R ❑ COS <br /> 304 CFR 112 . 5 (a) , 112 . 5(b) Failure to implement SPCC plan amendments within 6 months ❑ V ❑ R ❑ COS <br /> Qualified Facility - Tier 1 <br /> 401 CFR 112 . 6(a) , 112 . 6(b) Tier I Qualified Facility Plan not certified by the owner or a PE ❑ V ❑ R ❑ COS <br /> 402 CFR 112 . 6(a) (2) Owner of Tier I Qualified Facility failed to self certify technical amendment ❑ V ❑ R ❑ COS <br /> 403 CFR 112 . 6(a) (3) (i) Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged ❑ V ❑ R ❑ COS <br /> 404 CFR 112 . 6 (a) (3) (ii) No 2CT for bulk containers , or mobile storage containers not located to prevent discharge ❑ V ❑ R ❑ COS <br /> 405 CFR 112 . 6(a) ( 3) (iii) Overfill prevention for containers not provided , not described in Plan , or tested ❑ V ❑ R ❑ COS <br /> FA0010206 PR0516434 SCO01 02/11 /2019 <br /> EHD 28-01 Rev. 09/27/2018 Page 1 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 -3420 F 209 464 -0138 1 www . sjcehd . com <br />