My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2002 - 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:14:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2003
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDU TANK INFORMATION ANDWI -ST RESULTS <br /> &I i Tanlvxlllo W <br /> 8900 SHOAL CREEK, BUILDING 200 <br /> TEST DATE: 10/03/03 AUSTIN,TEXAS 78757(512)451-6334 WORK ORDER NUMBER: 2228697 <br /> CLIENT: VEEDER ROOT - CMS SITE: SAFEWAY 2600 <br /> .. <br /> Tank ID: 87 1 Tank manifolded: NO Bottom to top fill in inches: 185.0 <br /> Product: REG UNLEAD Vent manifolded: YES Bottom to grade in inches: 191.0 <br /> Capacity in gallons: 20,073 Vapor recovery manifolded: YES Fill pipe length in inches: 65.0 <br /> Diameter in inches: 120.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 414 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> xxx <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: <br /> Fluid volume in gallons: Model: <br /> Tank water level in inches: S/N: <br /> Test time: Open time in sec: <br /> Number of thermisters: NOT <br /> TESTED Holding psi: NOT NOT <br /> Specific gravity: Resiliency cc: TESTED TESTED <br /> Water table depth in inches: Test leak rate ml/m: <br /> Determined by(method): Metering psi: <br /> Leak rate in gph: Calib. leak in gph: <br /> Result: Results: <br /> COMMENTS COMMENTS <br /> Ah <br /> k' <br /> .. <br /> L[NE R <br /> B: ''. <br /> Test time: Material: APT FLEXIB APT FLEXIB <br /> Ullage volume: Diameter(in): 1.5 1.5 <br /> Ullage pressure: Length (ft): 125.0 125.0 <br /> Results: Test psi: 50 50 <br /> Bleedback cc: 220 240 <br /> DATA FOR UTS-4T ONLY: Test time (min): 30 30 <br /> Test 1: Start time: 15:45 15:55 <br /> Time of test 1: Finish psi: so so NOT NOT <br /> Temperature: NOT Vol change cc: 0 0 TESTED TESTED <br /> Test 2: Start time: 15:55 16:05 <br /> Flow rate (cfh): TESTED Finish psi: so so <br /> Time of test 2: Vol change cc: 0 0 <br /> Test 3: Start time: 16:05 16:15 <br /> Temperature: Finish psi: so so <br /> Flow rate (cfh): Vol change cc: 0 0 <br /> Time of test 3: Final gph: 0.000 0.000 <br /> Temperature: Result: PASS PASS <br /> Flow rate (cfh): Pump type: PRESSURE PRESSURE <br /> COMMENTS Pump make: FE PETRO FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 10/09/2003 14:21 SBOWERS <br />
The URL can be used to link to this page
Your browser does not support the video tag.