My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2002 - 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:14:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2003
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MonitorinoSystem. Equipment -irtification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work.A copy of this form must be provided <br /> to the tank system owner/Cfg.UserName. The owner/Cfg.UserName must submit a copy of this form to the local agency regulating UST sy: <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: Safeway 2600 Bldg.No.: <br /> Site Address: 1987 West 11Th. Street @ Corral Hallow City: Tracy, CA Zip: 95376- <br /> Facility Contact Person: Katrina Contact Phone No.: (209) 830-2950 <br /> Make/Model of Monitoring System: V/R TLS-350 Date of Testing/Servicing: 10/02/03 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID:01 -Regu Tank ID: 02-Plus <br /> ❑ In-Tank Gauging Probe. Model: VR 847390-107 ❑ In-Tank Gauging Probe. Model: VR 847390-107 <br /> ❑ Annular Space or Vault Sensor. Model: None ❑ Annular Space or Vault Sensor. Model: None <br /> ❑ Piping Sump\Trench Sensor(s). Model: None ❑ Piping Sump\Trench Sensor(s). Model: None <br /> ❑ Fill Sump Sensor(s). Model: None ❑ Fill Sump Sensor(s). Model: None <br /> ❑ Mechanical Line Leak Detector. Model: None ❑ Mechanical Line Leak Detector. Model: None <br /> ❑ Electronic Line Leak Detector. Model: None ❑ Electronic Line Leak Detector. Model: None <br /> ❑ Tank Overfill\High-Level Sensor. Model: None ❑ Tank Overfill\High-Level Sensor. Model: None <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 03-Prem Tank ID• <br /> ❑ in-Tank Gauging Probe. Model: VR 847390.107 ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: None ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump\Trench Sensor(s). Model: None ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: None ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: None ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: None ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: None ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 01-02 Dispenser ID: 03-04 <br /> ® Dispenser Containment Sensor(s). Model: VR 794380.208 Q9 Dispenser Containment Sensor(s). Model: VR 794380.208 <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 05-06 Dispenser ID• 07-08 <br /> 8 Dispenser Containment Sensor(s). Model: VR 794380.208 S Dispenser Containment Sensor(s). Model: VR 794380-208 <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 09-10 Dispenser ID: 11-12 <br /> M Dispenser Containment Sensor(s). Model: VR 794380-208 gg Dispenser Containment Sensor(s). Model: VR 794380.208 <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C. Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (check all that apply): ❑ System set-up ❑ Alarm history report <br /> Technician Name(print): SSS-RobertR Signature: Original on file at SSS <br /> Certification No.: 552-49-3710 License.No.: 485184 <br /> Testing Company Name: Ser. Sta. Sys. Phone No.: (408) 971-2445 <br /> Site Address: 1987 West 11Th. Street @ Corral Hallow Date of Testing/Servicing: 10/02/03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.