Laserfiche WebLink
OCT-01-2004 18 37 SERVICE STATION SYSTEM 40e 971 0135 P.06 <br /> Monitoring System Certification-Fay J of 3 <br /> Site Address: 1804 West 11Th. Street @ Corral Hallow Date of Testing/Servicing: 912104 <br /> F. In-Tank Ganging/SIR Equipment: @,g Check this box if tank gauging is used only for inventory contro <br /> L] Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist. <br /> ❑Yes ❑No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> ❑Yes ❑No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> C1 Yes p No* Was accuracy of system product level readings tested? <br /> ❑Yes ❑Na* Was accuracy of system water level readings tested? <br /> ❑Yes ❑No* Were all probes reinstalled properly? <br /> L]Yes 0 No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In Section H below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors(LLD); ❑ Check this box if LLD's are not installed. <br /> Complete the following checklist; <br /> Ig Yes p No* For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? <br /> ❑N/A (Check all that apply) Simulated leak reate: N 3 g.p.h. (1.); ❑ 0.1 g.p.h.(2.); o 0.2 g.p.h.(2). <br /> Notes: 1. Required for equipment start-up certification and annual certification. <br /> 2_ Unless mandated by local agency,certification required only for electronic LLD start-up. <br /> ❑Yes ig No* Were all LLD's confirmed operational and accurate within regulatory requirements? <br /> g Yes ❑No* Was the testing apparatus properly calibrated? <br /> Q Yes p No* For mechanical LLD's,does the LLD restrict product flow if it detects a leak? <br /> 11 N/A <br /> tg Yes ❑No* For electronic LLD's,does the turbine automatically shut off if the LLD detects a leak? <br /> ❑N/A <br /> Qg Yes p No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> ❑N/A or disconnected? <br /> Ig Yes p No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system <br /> ❑N/A malfunctions or fails a test? <br /> 19 Yes p No* For electronic LLD's,have all accessible wiring connections been visually inspected? <br /> ❑ N/A <br /> pg Yes ❑No* I Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In Section H below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: Regular north turbine PLLD did not pass 3 gph test possible air in line. <br />