My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RS -232 END OF MESSAGE <br />DISABLED <br />AUTO DIAL ALARM SETUP <br />D 2:FUEL SUPPLIER <br />IN -TANK SETUP <br />IN -TANK ALARMS <br />ALL:LOW PRODUCT ALARM <br />GULAR <br />ALL:INVALID FUEL LEVEL <br />SMARTSENSOR ALARMS <br />PRODUCT U <br />TCODE <br />1 <br />ALL:DELIVER'1 NEEDED <br />ALL:SETUP DATA WARNINGTHERMAL <br />COEFF :.000700 <br />ALL:COMMUNICATION ALARM <br />TANK DIAMETER <br />119.75 <br />D 8:VEEDER ROOT (FMS)- <br />TANK PROFILE <br />4 PTS <br />ALL:SENSOR FAULT ALARM <br />FULL VOL <br />20073 <br />IN -TANK ALARMS <br />ALL:FUEL WARNING <br />89.8 INCH VOL <br />16172 <br />ALL:LEAK ALARM <br />ALL:FUEL ALARM <br />59.9 INCH VOL <br />10063 <br />ALL:HIGH WATER ALARM <br />ALL:WATER WARNING <br />29.9 INCH VOL <br />3948 <br />ALL:OVERFILL ALARM <br />ALL:WATER ALARM <br />METER DATA <br />YES <br />ALL:LOW PRODUCT ALARM <br />ALL:HIGH LIQUID WARNING <br />END FACTOR: <br />NONE <br />ALL:SUDDEN LOSS ALARM <br />ALL:HIGH LIQUID ALARM <br />CAL UPDATE: IMMEDIATE <br />ALL:HIGH PRODUCT ALARM <br />ALL:LOW LIQUID WARNING <br />ALL:INVALID FUEL LEVEL <br />ALL:LOW LIQUID ALARM <br />ALL:PROBE OUT <br />ALL:TEMPERATURE WARNING <br />FLOAT SIZE: 4.0 <br />IN. <br />ALL:HIGH WATER WARNING <br />ALL:RELAY ACTIVE <br />ALL:DELIVERY NEEDED <br />ALL:INSTALL ALARM <br />WATER WARNING <br />2.0 <br />ALL:MAX PRODUCT ALARM <br />ALL:SENSOR FAULT WARN <br />HIGH WATER LIMIT: <br />3.0 <br />ALL:GROSS TEST FAIL <br />ALL:VACUUM WARIVING <br />ALL:PERIODIC TEST FAIL <br />ALL:NO VACUUM ALARM <br />MAX OR LABEL VOL: <br />20073 <br />ALL:ANNUAL TEST FAIL <br />OVERFILL LIMIT <br />9014 <br />ALL:PER TST NEEDED WRN <br />ISD SITE ALARMS <br />18065 <br />ALL:PER TST NEEDED ALM <br />ISD STAGE I WARN <br />HIGH PRODUCT <br />95% <br />ALL:NO CSLD IDLE TIME <br />ISD GROSS PRES WARN <br />19069 <br />ALL:CSLU INCR RATE WARN <br />ISD GROSS FRES FAIL <br />DELIVERY LIMIT <br />300% <br />ALL:ACCU_CHART CAL WARN <br />ISD DEGRD PRES WARN <br />6022 <br />ALL:RECON WARNING <br />ISD DEGRD PRES FAIL <br />ALL:RECON ALARM <br />ISD VAPOR LEAK WARN <br />LOW PRODUCT <br />800 <br />ALL:LOW TEMP WARNING <br />ISD <br />ISD VAPOR LEAK FAIL <br />LEAK ALARM LIMIT: <br />3 <br />ALL:GROSS FAIL LINE TNK <br />VP PRES WARN <br />SUDDEN LOSS LIMIT: <br />50 <br />ISD VP PRES FAIL <br />TANK TILT <br />0.00 <br />LIQUID SENSOR ALMS <br />ISD VP STATUS WARN <br />PROBE OFFSET <br />3.00 <br />ALL:FUEL ALARM <br />ISP VP STATUS FAIL <br />ALL:SENSOR OUT ALARM <br />MISSING RELAY SETUP <br />ALL:SHORT ALARM <br />MISSING HOSE SETUP <br />SIPHON MANIFOLDED <br />TANKS <br />ALL:WATER ALARM <br />MISSING TANK SETUP <br />TO: NONE <br />ALL:WATER OUT ALARM <br />MISS VAPOR FLOW MTR <br />LINE MANIFOLDED TANKS <br />MISS VAPOR PRES SEN <br />TO: NONE <br />ALL:HIGH LIQUID ALARM <br />MISSING VP INPUT <br />ALL:LOW LIQUID ALARM <br />ISD SETUP WARN <br />ALL:LIQUID WARNIIVG <br />ISD SETUP FAIL <br />LEAK MIN PERIODIC: <br />0%d <br />ISD SENSOR OUT WARN <br />0 <br />RECEIVER ALARMS <br />SERVICE REPORT WARNISD <br />SENSOR OUT FAIL <br />LEAK MIN ANNUAL <br />Ob <br />ALARM CLEAR WARNING <br />FC -ISD FAILURE <br />0 <br />COMM SIDE DIM ALM <br />ISD HOSE ALARMS <br />ALL:DISABLED DIM ALARM <br />ALL:GROSS COLLECT WARN <br />PERIODIC TEST TYPE <br />ALL:COMMUNICATION ALARM <br />ALL:GROSS COLLECT FAIL <br />STANDARD <br />ALL:TRANSACTION ALARM <br />ALL:DEGRD COLLECT WARN <br />ALL:DEGRD COLLECT FAIL <br />ANNUAL TEST FAIL <br />RECONCILIATION ALM <br />ALL:FLOW COLLECT WARN <br />ALARM DISABLED <br />ALL:PROD THRESHOLD ALM <br />ALL:FLOW COLLECT FAIL <br />ALL:CLOSE SHIFT WARNING <br />ALL:AIRFLOW MTR SETUP <br />PERIODIC TEST FAIL <br />ALL:CLOSE DAILY WARNING <br />ALARM DISABLED <br />VAPOR FLW MTR ALMS <br />PRESSURE LINE LEAK <br />ALL:CHK VAPOR FLOW MTR <br />GROSS TEST FAIL <br />ALL:GROSS LINE FAIL <br />ALARM DISABLED <br />ALL:ANNUAL LINE FAIL <br />PMC ALARMS <br />ALL:PER TST NEEDED ALM <br />VP RUNTIME FAULT <br />ANN TEST AVERAGING: <br />OFF <br />ALL:PLLD OPEN ALARM <br />VP EMISSIONS WARN <br />PER TEST AVERAGING: <br />OFF <br />ALL:UNKNOWN ALARM <br />VP EMISSIONS FAIL <br />ALL:UNKNOWN ALARM <br />VP PRESSURE WARN <br />TANK TEST NOTIFY: <br />OFF <br />ALL:UNKNOWN ALARM <br />VP PRESSURE FAIL <br />ALL:PERIODIC LINE FAIL <br />VP DUTY CYCLE WARN <br />TNK TST SIPHON BREAKOFF <br />ALL:ANN TST NEEDED ALM <br />VP DUTY CYCLE FAIL <br />ALL:LOW PRESSURE ALARM <br />PMC SETUP FAIL <br />DELIVERY DELAY <br />3 MIN <br />ALL:UNKNOWN ALARM <br />PUMP THRESHOLD <br />10.00% <br />ALL:CONT HANDLE ALM <br />ALL:FUEL OUT <br />ALL:LN EQUIP FAULT ALM <br />
The URL can be used to link to this page
Your browser does not support the video tag.