My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Fill Sump # Diesel <br />Sump Diameter: 48" <br />Sump Depth: 60" <br />Height from Tank Top to Top of 36" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest 19" <br />Electrical Penetration: <br />Condition of sump prior to Good <br />testing: <br />Portion of Sump Tested 2" above piping <br />Sump Material: Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and 30 minutes <br />starting test: <br />Test Start Time: 9:06 am <br />Initial Reading (R,): 3.3896 <br />Test End Time: 9:21 am <br />Final Reading (RF): 3.3910 <br />Test Duration: 15 min. <br />Change in Reading (117111): +0.0014 <br />Pass/Fail Threshold or Criteria: +/- 0.002" <br />Test Result: © Pass ❑ Fail <br />Is there a sensor in the sump? ® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is ❑ Yes ❑ No ® NA <br />detected? <br />Was sensor removed for testing? ® Yes ❑ No ❑ NA <br />Was sensor properly replaced and ® Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for jailed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />