2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
State Water Resources Control Board <br />Pagel of 2 <br />Home Water Issues Programs Ust > Leak Prevention » Lg113 » Vendors <br />UST Programs - LG 113 <br />.............I....I................................................................................................................................................ <br />Issue Date: September 22, 2004 <br />Revision Date: April 11, 2007 <br />Veeder-Root <br />TLS 350, 350PC, 350R, 350RPC, 350Plus, LLD -300, Red Jacket ProMax Leak Detector, <br />Series 8484, Software Version X19 or Higher <br />(for Rigid and/or Flexible Pipelines) <br />AUTOMATIC ELECTRONIC LINE LEAK DETECTOR <br />Certification Leak rate of 3.0 gph at 10 psi* with PD = 100% and PFA = 0%. <br />Leak rate of 0.2 gph at operating pressure with PD = 100% and PFA = 0%. <br />Leak rate of 0.1 gph at 1.5 times operating pressure* with PD = 100% and PFA = 0%. <br />*Since leak rate varies as a function of pressure, this leak rate and pressure were certified <br />using an equivalent leak rate and pressure, in accordance with an acceptable protocol. <br />Leak 1.5 gph for leak rate of 3.0 gph. <br />Threshold 0.17 gph for leak rate of 0.2 gph. <br />0.05 gph for leak rate of 0.1 gph. <br />A pipeline system should not be declared tight if the test result indicates a loss that equals or <br />exceeds this threshold. <br />Applicability Gasoline, diesel, aviation fuel, ethanol blends (with gasoline) between 0% and 98%, absolute <br />ethanol (100%)*, biodiesel and biodiesel blends(with diesel). <br />Other liquids may be tested after consultation with the manufacturer. <br />*LG 113 Listings apply to leak detection functionality only and not material compatibility — <br />see "Disclaimer." <br />Specification System tests pressurized rigid, flexible, and combination of rigid and flexible pipelines. <br />Tests are conducted at operating pressure. <br />System will not function with a mechanical line leak detector installed in the pipeline. <br />Pipeline Maximum of 119.4 gallons. <br />Capacity <br />Waiting Time None between delivery and testing. <br />None between dispensing and testing for leak rate of 3.0 gph. <br />Minimum of 4 minutes to 1 hour, 9 minutes between dispensing and testing for leak rate of <br />0.2 gph. <br />Minimum of 1 to 4 hours between dispensing and testing for leak rate of 0.1 gph. <br />Test Period Response time is 1 to 6 minutes for leak rate of 3.0 gph. <br />http://www.waterboards.ca.gov/water_issues/programs/ust/leak_prevention/lg 113/vendors/... 3/13/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.